INSTALLATION
All models
(For C6R/75U,C6R/100U,C6R/125U Models see additional instructions)
Note to installer
Please follow this instruction carefully. Only if the cabinet is correctly installed
will it give the best possible performance and reliability. Please pay particular
attention to the User maintenance section of this guide that the controller must
be left on the factory setting. There are also clear guidelines stating that the grill
on cabinet must not be blocked at any time and condenser must be cleaned
every 3 months. There are no user serviceable parts inside the refrigerated
compartment.
Inspection
On receipt, unpack the carefully and inspect for any superficial damage that
may have been sustained in transit. Record the nature of any damage on the
Carrier’s Delivery Note and at the same time inform your supplier.
Handling
Important: Keep the cabinet vertical and on its base, if the cabinet is tipped onto
its back, front or sides allow it to stand back on its base for at least 2 hours
before switching ON.
Ensure the cabinet is installed on a sound, level work surface, observing
requirements for ventilation as detailed on pages 10,11 & 12.Do not install this
cabinet close to any source of heat which may result in operating conditions
exceeding its design limits. Locations close to sources of moisture or steam will
cause excessive condensation on the outer surfaces of the cabinet and must be
avoided.
Ambient temperature range; minimum 18
o
C, maximum 25
o
CMaximum relative
humidity 60%.
General
Installation must only be carried out by a suitable trained person and comply
with national and local codes for connection to electrical supply.
The cabinet
must be earthed... the earthing of the installation a safety standard,
which is enforced by law. Do not switch on the unit the installation has
been completed.
Connecting to the electricity supply
The cabinet is completely factory wired and only needs to be connected to a
suitable power point (socket).It are recommended that the mains electricity
supply is protected by an RCCB (Residual current circuit breaker). Cabinets are
supplied with 2 metres of cable and should be connected to an earthed,
switched, 13 amp 230Volts socket which should be easily accessible for
isolation of the cabinet.
The socket should be installed in accordance with current I.E.E regulations. If in
doubt consult a qualified electrician. The 1989 Electricity at work Regulation
requires periodic testing of electrical equipment and should be carried out by a
competent person.
The cabinet are designed for indoor use only in ambient temperature between
minimum 18
o
C, maximum 32
o
C.The cabinet must be positioned on a flat level
surface. To reduce energy consumption position the cabinet in a well ventilated
location, away from sources of heat. It should not be exposed to water spillage.
Spray steam or high humidity. Failure to do so may reduce the efficiency of the
cabinet and increase the frequency of maintenance required. Particular
attention should be paid to airflow restriction into and out of the refrigeration
system, this is very important for the cabinet to operate efficiently.