IT-GB-FR
mod. 940-940/SA
56/112
APPPLIANCE REGULATION
(to be completely carried out before effecting the 1st Lighting)
REGULATION of Heating water Temperature.
The appliance is provided with a thermostat put on the boiler for the control of the water
temperature sent to the plant, this thermostat reduces progressively the power of the appliance
(modulation) whenever the temperature of the water inside the boiler has reached the selected
temperature.
TO SELECT Water temperature (boiler)
-
Push on button 1
-Regulate the temperature of plant utilizing the buttons P1 and P2
-Terminate the regulation of the temperature of the water pressing
shortly on button P4, the modification will be memorized and the disply
returns to the previous indication
REGULATION of Domestic water Temperature [not applicable for
940/SA
The appliance is provided with a thermostat for the control of the temperature of domestic
water, this thermostat regulates the power of the appliance in order to maintain the
temperature of the domestic water whenever required, it is suggested to keep this temperature
higher by 10°C in respect of the temperature of the water for the heating plant.
The production of domestic water occurs by mean of the use of a rapid exchanger, when
warm water is requested a feeler transfers this request to the appliance, which increases the
power to the max. level to satisfy the request and the power modulation will start as soon as
the selected value of domestic water temperature has been reached.
TO SELECT domestic water temperature
-
Push on button 6
-Regulate the temperature of plant utilizing the buttons
P1 and P2
-Terminate the regulation of the temperature of the water pressing
shortly on button P4, the modification will be memorized and the display returns to the
previous indication
REGULATION of the Power of the appliance.
The appliance has the possibility to be regulated within a range of 5 power levels (1-min, 5-
max), during the first working hours we suggest to put the power regulation on level 3.
The appliance will use the selected power value as maximum value for the function of heating
of the plant, in this way it is possible to restrict the max. power of the appliance.
In any case if the selected power permits to the boiler temperature to reach the selected value,
the appliance will automatically reduce the power (modulation) in order to reduce the
consumption of the fuel.
-
Push on P5
-
Regulate the power of the appliance utilizing the buttons P5 o P6
-
Terminate the regulation of the temperature of the water pressing
shortly on button P4, the modification will be memorized and the
display returns to the previous indication
Summary of Contents for 0000
Page 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Page 34: ...IT GB FR mod 940 940 SA 34 112 ...
Page 35: ...IT GB FR mod 940 940 SA 35 112 ...
Page 36: ...IT GB FR mod 940 940 SA 36 112 ...
Page 37: ...IT GB FR mod 940 940 SA 37 112 ...
Page 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Page 71: ...IT GB FR mod 940 940 SA 71 112 ...
Page 72: ...IT GB FR mod 940 940 SA 72 112 ...
Page 73: ...IT GB FR mod 940 940 SA 73 112 ...
Page 74: ...IT GB FR mod 940 940 SA 74 112 ...
Page 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Page 107: ...IT GB FR mod 940 940 SA 107 112 ...
Page 108: ...IT GB FR mod 940 940 SA 108 112 ...
Page 109: ...IT GB FR mod 940 940 SA 109 112 ...
Page 110: ...IT GB FR mod 940 940 SA 110 112 ...