How to pair

The system features Bluetooth

®

 Low Energy technology, which makes it capable of being controlled via the wireless LINAK

®

 hand 

controls. Furthermore, it makes it possible to control the bed via the Bed Control App. However, it can only receive commands from 
one device at a time, so the user must wait 5 seconds without pushing a button before it is possible to use another control/mobile 
device. 

Pairing 

1.  Connect the system to the mains via the connection cable.
2.  The LA18 is in pairing mode for 3 minutes and the Under Bed Light flashes to indicate this. 
  Press the two top buttons on the hand control at the same time. 

Now the light gives a long flash to indicate that the control and the LA18 are paired up. The LA18 stays in pairing mode and it is 
possible to connect more controls using the same procedure as above. 

Note: 
Wait 5 seconds after pairing control 1 before you can pair control 2. To get the system out of pairing mode – simply press any 
button on an already paired control.

Dual pairing 

Pairing one hand control to two LA18 requires a hand control that supports dual pairing.
1.  Connect the two LA18 to the mains at the same time.
2. The Under Bed Light starts to flash to indicate pairing mode has started.
3.  Take the hand control and press the two upper buttons and both products are paired to the hand control.
Now the light gives a long flash to indicate that the control and both the LA18 systems are paired up.

How to unpair one system
1.  Put the LA18 system you want to keep paired into pairing mode and pair the hand control.
2.  Send a command from the hand control and the pairing mode stops.
3.  The connection between the other LA18 system and the hand control is now deleted.

Summary of Contents for HOMELINE LA18 IC Standard Series

Page 1: ...Page 1 of 26 LINAK COM HOMELINE Actuator LA18 IC Standard User manual...

Page 2: ...uring operation 7 Misc 7 Only for EU markets 8 Only for Non EU markets 8 Misuse 8 Repairs 9 Manufacturer s declaration 9 Misc on the HOMELINE system 10 Warranty 10 Maintenance 10 ETL marking 11 System...

Page 3: ...the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK subsidia...

Page 4: ...for the following products See the first 3 5 characters on the label Actuators LA18 IC Standard Master and a LA18 IC Standard Follower Power supply SMPS001 SMPS002 or SMPS006 Wireless controls HC05 HC...

Page 5: ...tem or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access to this User Manual Follow the instructions for moun...

Page 6: ...component complies with relevant standards like the Machine Directive Care must be taken to avoid squeezing of cables as it can cause movement of the system The SMPS001 002 006 must not be packed in h...

Page 7: ...ct before the system is connected to the mains System connection The individual parts must be connected before the actuator system SMPS is connected to the mains See the User Manual for LINAK actuator...

Page 8: ...e or knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surve...

Page 9: ...TD5 Controls HB10 RF HB20RF HB60 HC10 HC10RF HC20RF HC40 Accessories Bluetooth Adapter DC CONNECTOR LED Lightbox Lightplug001 Massage Motor SMPS001 SMPS001 SMPS002 SMPS006 comply with the following pa...

Page 10: ...tampered with Furthermore the system must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid For further details please see LINAK A S ordinary condition...

Page 11: ...Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std No 68 09 ETL Recognized Component mark for Canada and United States ETL marking Due to space limitations the complete ETL markin...

Page 12: ...Standard Master and an LA18 IC Standard Follower The system is connected to the mains via an SMPS001 002 006 and controlled by a Bluetooth hand control HC05 Wireless HC10 Wireless HB10 Wireless or HC...

Page 13: ...g mode and it is possible to connect more controls using the same procedure as above Note Wait 5 seconds after pairing control 1 before you can pair control 2 To get the system out of pairing mode sim...

Page 14: ...ptimal cable relief on the SMPS001 002 a locking device 0705889 should be used Follow the guide below on how to fix the locking device on the SMPS 1 Take the SMPS 2 Plug the 2 poled DC cable in the SM...

Page 15: ...batteries are disposed through local recycling system Please do not throw used or leaking batteries in normal household waste or in nature This will cause damage to the enviroment How to deal with lea...

Page 16: ...Page 16 of 26 Labels Label for LA18 IC Standard Master Label for SMPS002 Label for LED Light Rail Label for LA18 IC Standard Follower Label for SMPS001 Label for SMPS006...

Page 17: ...Page 17 of 26 Label for HC05BL Label for HB10 BL Label for HC40 FRAME Standard Label for HC40 TWIST Standard Label for HC10BL...

Page 18: ...Page 18 of 26 DRAWING APPENDIX LA18 IC Standard Master LA18 IC Standard Follower...

Page 19: ...Page 19 of 26 LA18 IC Standard Master Click on back fixture LA18 IC Standard Follower Click on back fixture...

Page 20: ...Page 20 of 26 SMPS001 SMPS002...

Page 21: ...Page 21 of 26 SMPS006...

Page 22: ...Page 22 of 26 13 5 34 100 2 9 1 3 HC05 Wireless HC10 Wireless...

Page 23: ...Page 23 of 26 HC40 FRAMETM Standard 46 169 4 15 3 Created By Bjarne Skov 2019 04 12 Modified By Bjarne Skov 2019 04 12 SCALE 1 1 Drawing No HC40_TWIST_STANDARD HC40 TWISTTM Standard...

Page 24: ...Page 24 of 26 LED Light Rail HB10 Wireless...

Page 25: ...der which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condition...

Page 26: ...H Phone 49 6043 9655 0 Fax 49 6043 9655 60 www linak de India LINAK A S India Liaison Office Phone 91 120 4531797 Fax 91 120 4786428 www linak in Ireland LINAK UK Limited Ireland Phone 44 0 121 544 22...

Reviews: