Tabletop
Absorbing
material
Height of the DL1 in the lowest position
Min. desk height
Floor level
Mounting guidelines for the DESKLINE DL1A
Figure 2
Figure 1
The lifting units are normally mounted with the motor housings upwards and pointing towards each other
(see figure 2).
The aluminium motor housing is supplied with 6 pcs. of M6 threaded holes meant for mounting on the desk frame.
The threaded holes are rolled into the aluminium housing.
It is recommended to use all 6 M6 threaded holes. As the tabletop amplifies the sound we advise you to place a
vibration/shockabsorbing material between the tabletop and the table frame.
A suitable desk height in the lowest position can be obtained by mounting the lifting unit on a 6-8 mm bottom plate by means
of 4 pcs. of M6 countersinked screws. We recommend you to use screws of min. quality 8.8. The thrust moment must not
exceed 10 Nm in the bottom plate thread.
Max. 15 mm