SMB/SB Installation and Maintenance Manual
140-11000 • July 2003
To reinstall the Stem Nut onto a Threaded Shaft:
1. Rotate
the
Stem Nut on the shaft until the Stem Nut splines engage the Drive Sleeve splines.
2. Rotate the Handwheel to open the valve until the Stem Nut is seated.
3. Install the Locknut .
4. Stake the top threads in two (2) places, 180˚ apart.
7.2.4 Gasket Instructions
All gaskets except the housing cover gasket are 1/32" thick ASTM F104 synthetic fiber. The housing gaskets vary in thickness. To
determine the correct size, proceed as follows:
1. Clean
the
Housing Cover (piece #88) and the main Housing (piece #1) gasket surface.
2. Install the unit Drive Sleeve Assembly, including the Bearings.
3. Install
the
Housing Cover and measure the gap between the Housing Cover and the main Housing.
4. Take measurement and add 10%. Use the closest nominal gasket thickness or combination available.
7-11
Flow Control Division
Limitorque Actuation Systems