Summary of Contents for 400

Page 1: ...Illustrations Screw Black Red Black Red Black Red Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...

Page 2: ...0MΩ Frequency response 40Hz 400Hz Display effective value of sine wave mean value response C DC current Range Resolution Accuracy Overload protection UT39A UT39B UT39C 20µA 0 01µA 2 5 0 315A 250V fast type fuse ø5x20mm 200µA 0 1µA 0 8 3 2mA 1µA 0 8 1 0 8 1 20mA 10µA 200mA 100µA 1 5 1 10A 20A 10mA 2 5 Un fused Remark UT39A UT39B At 10A range For continuous measurement 10 seconds and interval not le...

Page 3: ...effective value of sine wave mean value response E Resistance test Range Resolution Accuracy Overload protection UT39A UT39B UT39C 200Ω 0 1Ω 0 8 3 250V DC or AC rms 2kΩ 1Ω 0 8 1 0 8 1 20kΩ 10Ω 200kΩ 100Ω 2MΩ 1kΩ 0 8 1 20MΩ 10kΩ 1 2 200MΩ 100kΩ 5 reading 10 10 Remark Open circuit voltage At 200MΩ range approx 3V Other ranges 700mV At 200MΩ range test lead is in short circuit and it is normal to dis...

Page 4: ...00nF 0 1nF 2µF 1nF 4 3 20µF 10nF 4 3 Remark Testing signal approx 400Hz 40mV rms I Diodes and continuity test Function Range Resolution Input Protection Remark Diode 1mV 250V DC or AC Open circuit voltage approx 2 8V Continuty buzzer 1Ω Approx 70Ω buzzer beeps continuously J Transistor test Range Remark Overload protection hFE Can measure NPN or PNP transistor Display range 0 1000β Vce 2 8V I bo 1...

Page 5: ...400 English 1 Svenska 5 Norsk 9 Dansk 13 Suomi 17 Deutsch 21 Netherlands 25 Français 29 Italiano 33 Español 37 Português 41 Polski 45 Eesti 49 Lietuviškai 53 Latviski 57 ...

Page 6: ...V type 6F22 Fuse 0 315A 250V fast type 5x20 mm Safety Compliances IEC61010 CAT II 1000V CAT I 600 V over voltage and double insulation standard Certification CE Safety Information This Meter complies with the standards IEC61010 Isolation category CAT II 600V CAT I 1000V Warning To avoid possible electric shock or personal injury and to avoid possible damage to the Meter or to the equipment under t...

Page 7: ... in order to obtain a correct reading In each range the Meter has an input impedance of approx 10MΩ This loading effect can cause measurement errors in high impedance circuits If the circuit impedance is less than or equal to 10kΩ the error is negligible Current measurement DC and AC Fig 2 Warning Never attempt an in circuit current measurement where the voltage is greater than 250 V If the fuse b...

Page 8: ...r electrical componens The measuring voltage is around 3 V To avoid damage of instruments disconnect circuit power and discharge high voltage capacitors 1 Insert the red test lead into the VΩHzºC terminal and the black test lead into the COM terminal 2 Set the rotary switch to continuity position 3 Connect the test leads across with the object being measured The buzzer sounds if the resistance is ...

Page 9: ...ion 3 Remove the screw and separate the battery lid 4 Replace with a new 9V battery type 6F22 Replace the fuse Fig 7 Replacement of the fuses is seldom required Burning of a fuse always results from improper operation 1 Disconnect the connection between the testing leads and the circuit under test 2 Turn the Meter to OFF position 3 Remove battery lid holster screws and separate case bottom 4 Repla...