Clean the product with a damp 
soft cloth or sponge, using only 
warm water with mild detergent.
The product must be stored dry.

Do not allow young children 
to use this product.

SAFETY & 

CLEANING 

INSTRUCTIONS

DO’s

STORAGE & TRANSPORTATION

DON’Ts

Follow all instructions.
Keep these instructions.
Heed all warnings.

Do not install near any heat sources, 
do not expose the product to flames 
or use near naked flame sources.
Do not use flammable solvents near or 
on this product.

Only use attachments/accessories 
specified by Limbs & Things

Never use the product outdoors 
as this may damage the product.

If a product is damaged or worn, it should 
be repaired by Limbs & Things. To arrange 
this, please contact your point of purchase 
who will be able to provide a repair quote.

The trainer and its accessories are 
heavy when packed in the carrying 
case.

Always ensure that the products are 
properly packed and secured during 
transportation and storage in order to 
prevent personal injury or damage to 
the product.

Do not disassemble the product or 
attempt to repair a faulty unit, please 
return the product to Limbs & Things 
for assessment and repair.

READ THE SAFETY INSTRUCTIONS CAREFULLY 

BEFORE USING YOUR CHEST DRAIN & NEEDLE 

DECOMPRESSION TRAINER

Summary of Contents for 60230

Page 1: ...imbsandthings com FOR MORE SKILLS TRAINING PRODUCTS VISIT Sussex Street St Philips Bristol BS2 0RA UK sales limbsandthings com 44 0 117 311 0500 CHEST DRAIN NEEDLE DECOMPRESSION TRAINER USER GUIDE 60230 ...

Page 2: ...INFORMATION 5 SET UP 6 REMOVING THE TORSO SKIN 6 INSERTING THE RIBS INTO A PAD 7 FITTING A PAD 8 REMOVING THE NEEDLE DECOMPRESSION PADS 10 FITTING THE NEEDLE DECOMPRESSION PADS 11 FILLING THE CHEST RESERVOIRS 12 USING THE NEEDLE DECOMPRESSION PUMP 13 USING THE RESPIRATORY SWING PUMP 14 CLEANING STORAGE 15 EMPTYING THE CHEST RESERVOIRS 15 REMOVING FITTING THE LUNG DIAPHRAGM 15 ...

Page 3: ...x2 60234 ADVANCED CHEST DRAIN PADS x2 60232 00293 NEEDLE DECOMPRESSION PADS x2 60231 CHEST DRAIN RIB FRAME LEFT 60235 CHEST DRAIN RIBS x12 CHEST DRAIN PUMP RESPIRATORY SWING CHEST DRAIN PUMP NEEDLE DECOMPRESSION 60240 CHEST DRAIN RIB FRAME RIGHT 60237 60238 60239 CHEST DRAIN LUNGS x2 CHEST DRAIN DIAPHRAGMS x2 PLASTIC FUNNEL LUBRICATING JELLY ...

Page 4: ...y Limbs Things Never use the product outdoors as this may damage the product If a product is damaged or worn it should be repaired by Limbs Things To arrange this please contact your point of purchase who will be able to provide a repair quote The trainer and its accessories are heavy when packed in the carrying case Always ensure that the products are properly packed and secured during transporta...

Page 5: ...l not self seal Improved respiratory swing Recommend usage of 12 FG catheter For open surgical techniques Can also be used for guide wire techniques where no fluid is required Not ultrasoundable Not suitable for use with liquids Tough skin for incision and suturing Foam chest wall for blunt dissection Pleural layer providing realistic give or pop on puncture Can be used with adhesive dressings Nee...

Page 6: ...6 1 3 2 SET UP REMOVING THE TORSO SKIN ...

Page 7: ...7 1 3 2 INSERTING THE RIBS INTO A PAD Make sure that all of the ribs curve in the same direction ...

Page 8: ...8 1 2 FITTING A PAD 3 ...

Page 9: ...9 4 5 ...

Page 10: ...10 1 2 REMOVING THE NEEDLE DECOMPRESSION PADS 3 ...

Page 11: ...11 1 2 FITTING THE NEEDLE DECOMPRESSION PADS 3 Choose the correct pad for LEFT or RIGHT side of the chest ...

Page 12: ...12 1 3 FILLING THE CHEST RESERVOIRS 2 While pouring check the pad frame for leaks Tighten the knobs on the frame if required ...

Page 13: ...13 1 2 3 4 USING THE NEEDLE DECOMPRESSION PUMP Release any residual air in the system The left and right systems function independently Close the bleed valve ...

Page 14: ...ing keep your thumb in position and alternately squeeze and release the pump to make the fluid level rise and fall To reproduce the bubbling effect of coughing squeeze the pump hard while keeping your thumb over the inlet The left and right systems function independently ...

Page 15: ...15 EMPTYING THE CHEST RESERVOIRS REMOVING FITTING THE LUNG DIAPHRAGM CLEANING AND STORAGE STORE DRY ...

Page 16: ...Part No 065 969 Issue 4 January 2019 2019 Limbs Things 60100 60000 YOU MAY ALSO BE INTERESTED IN ABDOMINAL EXAMINATION TRAINER PARACENTESIS TRAINER ...

Reviews: