37
Other Camera models and Video Encoder model with Load Default
Button.
To restore the server to factory default settings, please:
1. Hold Load Default Button for 10 second
2. Green network LED blinks, On->Off-,ON, to complete load default
setting
3. The server board reboots itself.
4. Using IPScan scanning for the IP address of the IP device.
5. Launch Internet browser for the IP address of the IP device.
6. Type default username “admin” and password “pass” for enter web
interface of the IP device.
DIP Switch Settings
The DIP switch settings (manufacturing default) are defined as follows:
DIP Switch #1: RS-485 IN Terminal Resistor ON/OFF is set to ON.
DIP Switch #2: RS-485 OUT Terminal Resistor ON/OFF is set to ON
DIP Switch #3: RS-485 Communication Mode Selection is set to OFF
for half duplex access.
DIP Switch #4 and #5: Transmission Speed Setting is set to 9600 bps.
DIP Switch #6, #7, #8, and #9: Protocol Setting is set to MLP2.
Camera/RS-485 ID address setting is set to ID #1.
Note:
GPIO #6 is revered for emergency factory default. Do not connect GPIO #6
for alarm notification purpose.
Note:
For convenient purpose, IP address resets to default IP address,
192.168.0.200, after performing Load Default operation.