SMAX MODBUS®
check box is not selected instead, you must press the
button to store the parameters permanently on the EEPROM after
setting (see on page 38).
In this section the items listed hereafter are available.
Total resolution
It allows both to set a custom resolution of the encoder (measuring step tailored
for the specific application) and to show the value that is set currently. You can
select one of the resolution options available in the drop-down menu or set a
custom value. The custom value must be expressed in hundredths of a
millimetre. See the
register on page 59. This register
item is enabled (=1).
Preset value
It allows both to set the preset value and to show the value that is set currently.
To execute the preset operation you must then press the
item at the bottom of the page: it executes the whole
sequence of preset commands (activation of the
and registers setting; deactivation of the
registers setting; save of parameters). Refer also to page 37. For more
information refer to the
Offset value
It shows the offset value which results from the setting of the
. For
Node address
It allows both to set the node address of the device and to show the value that
is set currently. For more information refer to the
register on page 65.
Baud rate
It allows both to set the baud rate of the encoder's serial communication and to
show the value that is set currently. The current setting is shown in the drop-
down box. The decimal value that results from the current setting (4 in the
MAN SMAX MB E 1.2
Quick reference