Ax58…Axx-…
5.3 Output signals description
•
+Iout
: analogue current output;
•
+Vout
: analogue voltage output;
•
Analogue 0VDC
: analogue reference,
internally connected to 0VDC;
•
Fault:
error signal for cable integrity check.
Only available for current outputs.
To connect the fault signal, see Figure 2 and
Figure 3, pay attention to R2 value.
No encoder error = transistor ON (conducting).
Encoder error = transistor OFF (open).
AI1, AI2, AI3
AV1, AV2, AV3, AV4
Figure 1
5.4 Input signals description
•
+15VDC +30VDC, 0VDC
: power supply;
•
Zero setting
: active high from 15V to 30V, it
sets the current position of the encoder to
the minimum analogue value (quote 0);
•
Complementary
: active high from 15V to
30V; if not active the position value output
increases when the encoder shaft rotates
clockwise (CW); if active the position value
output increases when the encoder shaft
rotates counter-clockwise (CCW);
•
Hold
: data latch, active high from 15V to
30V, only available for MIL 7 connector.
5.5 Fault output
5.5.1 Fault output connected to PLC input
Figure 2
Example
1K
Ω
< R2 < 10K
Ω
No encoder error = PLC input Low (0
VDC).
Encoder error = PLC input High (+VDC).
5.5.2 Fault output connected to a relay
Imax = 50mA
R1 = 47
Ω
R1
I
Vdc
R2
−
=
Figure 3
MAN Ax58 Axx I_E 1.6.odt
11
www.lika.it