Introduction 

General  Installation  Manual  for  BaoDing  Lightway  Green  Energy  Technology  Co.,  Ltd

.

  Photovoltaic  Modules 

Please read this manual completely before installing or using the Lightway modules. 

Thank  you  for  choosing  BaoDing  Lightway  Green  Energy  Technology  Co.,  Ltd.  Photovoltaic  modules.  With 

proper  operation  and  maintenance,  Lightway  Green  new  energy  PV  modules  will  provide  you  with  clean, 
renewable  solar  electricity  for  many  years.  Retain  this  manual  for  reference.  This  manual  contains  important 
installation, maintenance and safety information. Retain this installation manual for future reference.    The word 
“module” as used in this manual refers to one or more photovoltaic modules. 

General Information 

The installation of solar modules requires a great degree of skill and should only be performed by qualified 

licensed professionals, including, without limitation, licensed contractors and licensed electricians.

 

Warning

 

All  instructions  should  be  read  and  understood  before  attempting  to  install,  wire  operate  and  maintain  the   

photovoltaic module. Contact with

 e

lectrically active parts of the module such as

 

terminals can result in burns, 

sparks, and lethal shock whether the module is connected or disconnected. 

The installer assumes the risk of all injury that might occur during installation, including, without limitation, the 

risk of electric shock. 

PV  modules  generate  DC  electrical  energy  when  exposed  to  sunlight  or  other  light  sources.  Although  single 

modules produce only a low voltage and current, shocks and burns are still a potential hazard. 

To avoid  the  hazard  of  electric  shock  and  injury,  cover  all over  the  front surface  of  PV modules with  a  dense 

opaque material such as the cardboard box during installing and handling modules. 

The  shock  hazard  increases  as modules are  connected  in  parallel  producing  higher  current.  The  shock  hazard 

increases  as  modules  are  connected  in  series  producing  higher  voltages.  A  nominal  open  voltage  or  maximum 
system voltage of 45 V or more may cause an electric shock. 

To avoid the hazard of electric shock, work only under dry conditions, with dry module and tools. 

Do not stand or step on a module to avoid the hazard of injury and the damage to a module. 

Do not damage the back sheet of a module, to avoid the hazard of electric shocks and fire. 

To avoid the hazard of electric shock and injury, Children and unauthorized persons should not be allowed near 

the installation of the solar cell modules. 

To avoid the hazard of electric shock and injury ,do not disconnect during load connection. 

To avoid the hazard of electric shock and injury, be sure to ground the modules completely. 

To  avoid  the  hazard  of  electric  shock,  fire  and  injury,  do  not  disassemble  the  module,  or  remove  any  part 

installed by the manufacturer. 

Unauthorized persons should not open the cover of the junction box to avoid the hazard of electric shock. 

Do  not  touch  terminals  while  a  module(s)  is  exposed  to  light.  Provide  suitable  guards  to  prevent  yourself 

contacting directly with 30 VDC or greater to avoid the hazard of electric shock or injury. 

When carrying a module, more than two persons should carry it by the frame and wear non-slip gloves to avoid 

the hazard of injury by slipping down the module on a foot or cutting by an edge of the frame and so on. 

Do not carry a module by wire or junction box to avoid the hazard of electric shock and injury or any troubles in 

a module, which it may cause. 

Do not drop anything on the surfaces of modules to avoid the hazard of electric shock and injury or any troubles, 

Summary of Contents for LW6M60-260

Page 1: ...Park Gaobeidian Hebei Province P R China Tel 86 312 2951122 Fax 86 312 2951166 P C 074000 Email info lightwaysolar com www lightwaysolar com The Energy Depot Australia Add 1 4 Bridge Rd Keysborough V...

Page 2: ...rface of PV modules with a dense opaque material such as the cardboard box during installing and handling modules The shock hazard increases as modules are connected in parallel producing higher curre...

Page 3: ...means the positive pole of one module connect with the positive pole of another module and the negative pole of one module connect with the negative pole of another module Cautions Follow all permiss...

Page 4: ...the height of the mounting system So that the lowest edge of the Modules is not covered by snow for any length of time In addition ensure that the lowest portion of the Modules is placed high enough...

Page 5: ...ansported in the supplied packaging Installation only and kept in the packaging until they are ready to be installed Protect pallets against movement and exposure to damage during transportation Secur...

Page 6: ...les prior to installation the PV modules should remain inside the packaging and protected from exposure that could compromise the durability of the packaging Selecting the location Select a suitable l...

Page 7: ...ries 1640 990 35series 1640 992 35series 1680 992 35series 1680 990 35series 1665 1002 35series 1684 1002 35series shall be installed with a rack structure by using 4 sets of an M8 screw two flat wash...

Page 8: ...m Clamp material should be anodized aluminum alloy Floating type clamps are not authorized Clamp positions are of crucial importance for the reliability of the installation the clamp centerlines must...

Page 9: ...under large current Please pay attention the temperature limit of cable is 85 Functional earth the negative pole of the system will prevent the PID effect from happening However the earthing applicati...

Page 10: ...les because the current from other cells in the same series is forced to flow through the shaded area and then undesirable heating may occur The use of a diode to bypass the shaded area can minimize b...

Page 11: ...inspected by the installer or other qualified person The purpose of the PV system inspection is to ensure that all system components are functioning properly At a minimum this inspection should confir...

Page 12: ...bstances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your o...

Page 13: ...Lightway PV Modules Installation Manual Page 12 36 www lightwaysolar com If it is inconsistent between the different languages the English version shall be prevail...

Page 14: ...Lightway PV Modules Installation Manual Page 13 36 www lightwaysolar com REAR AND SIDE VIEW DIMENSIONS UNITS mm 1956 1960 990 992 40 Multi poly Mono poly Series...

Page 15: ...Lightway PV Modules Installation Manual Page 14 36 www lightwaysolar com...

Page 16: ...Lightway PV Modules Installation Manual Page 15 36 www lightwaysolar com 1650 990 992 40 Multi poly Mono poly Series...

Page 17: ...Lightway PV Modules Installation Manual Page 16 36 www lightwaysolar com 1640 990 992 40 Multi poly Mono poly Series...

Page 18: ...Lightway PV Modules Installation Manual Page 17 36 www lightwaysolar com 1650 990 992 35 Multi poly Mono poly Series...

Page 19: ...Lightway PV Modules Installation Manual Page 18 36 www lightwaysolar com 1640 990 992 35 Multi poly Mono poly Series...

Page 20: ...Lightway PV Modules Installation Manual Page 19 36 www lightwaysolar com 2006 992 990 40 Multi poly...

Page 21: ...Lightway PV Modules Installation Manual Page 20 36 www lightwaysolar com 1680 992 990 40 Multi poly...

Page 22: ...Lightway PV Modules Installation Manual Page 21 36 www lightwaysolar com 1680 992 990 35 Multi poly...

Page 23: ...Lightway PV Modules Installation Manual Page 22 36 www lightwaysolar com 1979 1002 40 Mono poly Series...

Page 24: ...Lightway PV Modules Installation Manual Page 23 36 www lightwaysolar com 2008 1002 40 Mono poly Series...

Page 25: ...Lightway PV Modules Installation Manual Page 24 36 www lightwaysolar com 1845 1002 998 35 Mono poly Series...

Page 26: ...Lightway PV Modules Installation Manual Page 25 36 www lightwaysolar com 1684 1002 40 35 Mono poly Series...

Page 27: ...Lightway PV Modules Installation Manual Page 26 36 www lightwaysolar com 1665 1002 40 35 Mono poly Series...

Page 28: ...310W LW6P72 340W LW6P60 270W LW6PH72 335 LW6PH60 305W LW6P72 335W LW6P60 265W LW6PH72 375W LW6PH60 300W LW6P72 330W LW6P60 260W LW6PH72 370W LW6PH60 295W LW6P72 325W LW6P60 255W LW6PH72 365W LW6PH60...

Page 29: ...370W LW6MH60 330W LW6M72 335 LW6M60 270 LW6MH72 405W LW6MH66 365W LW6MH60 325W LW6M72 330 LW6M60 265 LW6MH72 400W LW6MH66 360W LW6MH60 320W LW6M72 325 LW6M60 260 LW6MH72 395W LW6MH66 355W LW6MH60 315...

Page 30: ...y Series 1960 992 40 Mono poly Series 1665 1002 40 Mono poly Series 1684 1002 40 Mono poly Series 1845 1002 40 Mono poly Series 1979 1002 40 Mono poly Series 2008 1002 40 Mono poly Series 1845 998 40...

Page 31: ...5 39 81 9 42 47 37 9 85 1500 15 20 4mm2 1680 992 40 Multi poly Series 1680 992 35 Multi poly Series 1680 990 40 Multi poly Series 1680 990 35 Multi poly Series LW6PH60 280 280 31 65 8 85 37 89 9 37 15...

Page 32: ...tput tolerances Series Module Pmax Vmpp Impp Voc Isc Max system voltage V Max series fuse rating A Cable Diameter W V A V A 1956 990 40 Multi poly Series 1956 992 40 Multi poly Series 1960 990 40 Mult...

Page 33: ...ly Series 1650 1640 9 92 40 Multi poly Series 1650 1640 9 90 35 Multi poly Series 1650 1640 9 92 35 Multi poly Series LW6P60 255W 255 30 31 8 42 37 31 8 93 1000 15 20 4mm2 LW6P60 260W 260 30 53 8 52 3...

Page 34: ...ly Series 1650 1640 990 35 Mono poly Series 1650 1640 992 35 Mono poly Series 1665 1002 35 Mono poly Series LW6M60 260 260 30 78 8 45 37 61 9 02 1500 15 20 4mm2 LW6M60 265 265 31 04 8 54 37 82 9 10 15...

Page 35: ...65 38 03 9 18 1000 15 20 4mm2 LW6M60 275W 275 31 43 8 75 38 24 9 28 1000 15 20 4mm2 LW6M60 280W 280 31 72 8 83 38 42 9 38 1000 15 20 4mm2 LW6M60 285W 285 31 92 8 93 38 62 9 48 1000 15 20 4mm2 LW6M60...

Page 36: ...20 4mm2 LW6MH60 330 330 34 13 9 67 40 87 10 26 1500 15 20 4mm2 LW6MH60 325 325 33 86 9 60 40 62 10 19 1500 15 20 4mm2 LW6MH60 320 320 33 58 9 53 40 36 10 12 1500 15 20 4mm2 LW6MH60 315 315 33 30 9 46...

Page 37: ...4 1002 3 5 Multi poly Series LW6MH60 345W 345 34 92 9 88 41 60 10 47 1500 15 20 4mm2 LW6MH60 340W 340 34 66 9 81 41 36 10 40 1500 15 20 4mm2 LW6MH60 335W 335 34 40 9 74 41 12 10 33 1500 15 20 4mm2 LW6...

Reviews: