The 3-Way Control Relay is designed to switch mains
rated resistive loads and is rated at up to 3000w (total
capacity of all 3 channels added together)/. It is mains
powered. Each channel can be operated
independently. The relay can be operated using any
LightwaveRF Connect Remote or other transmitter.
FITTING AND WIRING INSTRUCTIONS:
Important Things to Consider Before you Begin
1). Before commencing work, ALWAYS isolate the
mains power supply and remove the fuse in the fuse
box or switch off the circuit breaker in the consumer
unit.
2). If unit is to be used as a replacement for an existing
product, remove existing unit from its location and
disconnect the wiring.
3). Connect the wires as shown in appropriate wiring
diagrams. Use green/yellow sleeving on any earth
conductors not insulated. Ensure terminals are
properly tightened and no bare wire is visible. When
mounting products into mounting boxes make sure
conductors are not trapped.
4). Products must be installed in accordance with the
latest building and IEE wiring regulations. If in any
doubt, please contact a qualified electrician.
Summary of Contents for LW825
Page 3: ...INSTALLATION 1 2 3 Switched Circuits...
Page 7: ......