Lightwave LP70 Instructions Download Page 3

Installing the Sensor

Carefully follow the instructions in this section in order 
to install the Sensor. For other advice, please contact our 
dedicated  technical  support  team  at 

www.lightwaverf.

com

.

The easiest way to learn how to install the Lightwave 

Smart  Sensor  is  to  watch  our  short  installation  video 

which is accessible at

www.lightwaverf.com/product-manuals

Creating Automations

This  PIR  can  be  added  to  the  Link  Plus  app  as  a  Smart 
Device.  Once  added you  can  then  create  an  IF  -  DO  or 
a  motion  automation  to  define  which  devices  within 
your  Lightwave  system  you  want  to  trigger.  Within  this 
automation you can adjust the LUX (light) level and also 
set a delay between your actions. (Please refer to the app 
guide  under  Help  &  Support  on  the  website  for  further 
information: www.lightwaverf.com)

LITHIUM BATTERY CAUTION

Lithium  ion  batteries  may  explode  or  burn  due  to 
improper  use.  Using  these  batteries  for  purposes  not 
intended by the manufacturer, may cause severe injury 
and  damage.  Keep  away  from  Children  and  animals. 
Lightwave are not responsible for any damage or injuries 
caused by batteries - use at your own risk.

 Please check 

with  your  local  authority  on  how  to  recycle  batteries 
responsibly.

2

3

Linking the Sensor & other functions

Unlinking the Sensor (clear memory)

To unlink the Sm

art Sensor, delete any automations you 

have set-up and delete the device from the app under 
the  device  settings  in  the  Lightwave  app.  Remove  the 
back cover of the device, press the ‘Learn’ button once 
and let go, then press and hold the ‘Learn’ button again 
until  the  LED  on  the  front  of  the  device  flashes  red 
rapidly. The memory of the device is cleared.

Firmware updates

Firmware 

updates 

are 

over-the-air 

software 

improvements that keep your device up to date as well 
as  providing  new  features.  Updates  can  be  approved 
from the App before being implemented, and generally 
take  2-5  minutes. The  LED will  flash  cyan  in  colour  to 
indicate the update has been initiated but will remain off 
for the remainder of the process. Please do not interrupt 
the process during this time, it can take up to an hour.

Support

  

If any issues are encountered once set-up and installa-
tion is completed, please contact Lightwave support via 

 

www.lightwaverf.com/support

.

 

Follow  the  in-app  instructions  which 
will explain how to link devices.

Remove  the  back  cover  of  the  Smart 
Sensor  using  a  screwdriver.  Open  the 
Lightwave  app  on  your  smart  device 
and select ‘+’ to add a new device and 
follow the instructions.

Press  the  ‘Learn’  button  on  the  Smart 
Sensor until the LED flashes blue then 
red  on  the  front  of  the  product. Then 
press the green ‘Link’ button on the app 
screen. The LED will then rapidly flash 
blue to indicate successful linking.

Linking

 

To be able to command the Sensor, you will need to link it 

to the Link Plus.

Inserting the battery

To  insert  the  CR2477  coin  cell  into  your  device,  first 

undo the screw by turning counter clockwise to remove 

the  back  cover  using  a  flat  head  screwdriver  (1). Then 
remove  the  rear  plastic  and  the  spacer  to  reveal  the 
battery  compartment.  If  replacing  a  battery  (2&3),  first 
remove  the  existing  battery  before  inserting  the  new 
one,  use  a  screw  driver  to  lift  the  old  battery  out  if 
necessary (4). To insert the battery, gently tilt at an angle 
towards the metal contact at the edge of the battery slot. 
Ensuring the positive symbol (+) is facing upwards, with 
very light pressure, push the battery down (5). Once the 
battery is inserted correctly, the LED will flash green. If 
installing this device for the first time, complete linking 
the  Sensor  now.  Then,  replace  the  spacer,  followed 
by  the  rear  plastic  (6)  and  affix  by  turning  the  screw 
clockwise using a flat head screwdriver (7).

When the Smart Sensor starts for the first time, please 
allow  at  least  15  seconds  to  allow  the  Sensor  run  it’s 
initial set up to allow for motion detection.

Inserting the battery and mounting

Follow the instructions below to insert the CR2477 coin cell into the device. Then follow the linking instructions to pair your device to your Link Plus. Ensure you mount the Sensor 
following the guidelines for optimum performance.

1

5

Mounting on a vertical surface

Using a cross head screw driver, mount the magnetic 
base on a flat surface. Gently attach the Sensor to 
the  magnetic  mount  ensuring  the  Fresnel  lens  is 
not  upside  down.  (Looking  closely  at  the  Fresnel 
lens,  the  larger  rectangular  boxes  are  at  the  top, 
orientation indicated on previous image). Adjust the 

viewing angle to suit the environment you wish to 
detect movement within.

4

7

6

Detecting Range and Viewing Angle

Recommendation for optimum performance at 6 
meters with a 90 degree viewing angle is for the 
Sensor to be mounted at 1.5 meter height.

The sensitivity of the Sensor can be adjusted in 
the  Lightwave  app.  Please  be  aware  that  when 
you  ‘save’ your  settings,  the  device will  then  be 
updated  with  the  new  sensitivity  setting  when 
next triggered.

The Lightwave app now has a motion automation 
to  allow  for  easier  set-up.  The  ‘IF  -  DO’ 
automation can also still be used. 

2 & 3

Reviews: