Installing the Sensor
Carefully follow the instructions in this section in order
to install the Sensor. For other advice, please contact our
dedicated technical support team at
www.lightwaverf.
com
.
The easiest way to learn how to install the Lightwave
Smart Sensor is to watch our short installation video
which is accessible at
www.lightwaverf.com/product-manuals
Creating Automations
This PIR can be added to the Link Plus app as a Smart
Device. Once added you can then create an IF - DO or
a motion automation to define which devices within
your Lightwave system you want to trigger. Within this
automation you can adjust the LUX (light) level and also
set a delay between your actions. (Please refer to the app
guide under Help & Support on the website for further
information: www.lightwaverf.com)
LITHIUM BATTERY CAUTION
Lithium ion batteries may explode or burn due to
improper use. Using these batteries for purposes not
intended by the manufacturer, may cause severe injury
and damage. Keep away from Children and animals.
Lightwave are not responsible for any damage or injuries
caused by batteries - use at your own risk.
Please check
with your local authority on how to recycle batteries
responsibly.
2
3
Linking the Sensor & other functions
Unlinking the Sensor (clear memory)
To unlink the Sm
art Sensor, delete any automations you
have set-up and delete the device from the app under
the device settings in the Lightwave app. Remove the
back cover of the device, press the ‘Learn’ button once
and let go, then press and hold the ‘Learn’ button again
until the LED on the front of the device flashes red
rapidly. The memory of the device is cleared.
Firmware updates
Firmware
updates
are
over-the-air
software
improvements that keep your device up to date as well
as providing new features. Updates can be approved
from the App before being implemented, and generally
take 2-5 minutes. The LED will flash cyan in colour to
indicate the update has been initiated but will remain off
for the remainder of the process. Please do not interrupt
the process during this time, it can take up to an hour.
Support
If any issues are encountered once set-up and installa-
tion is completed, please contact Lightwave support via
www.lightwaverf.com/support
.
Follow the in-app instructions which
will explain how to link devices.
Remove the back cover of the Smart
Sensor using a screwdriver. Open the
Lightwave app on your smart device
and select ‘+’ to add a new device and
follow the instructions.
Press the ‘Learn’ button on the Smart
Sensor until the LED flashes blue then
red on the front of the product. Then
press the green ‘Link’ button on the app
screen. The LED will then rapidly flash
blue to indicate successful linking.
Linking
To be able to command the Sensor, you will need to link it
to the Link Plus.
Inserting the battery
To insert the CR2477 coin cell into your device, first
undo the screw by turning counter clockwise to remove
the back cover using a flat head screwdriver (1). Then
remove the rear plastic and the spacer to reveal the
battery compartment. If replacing a battery (2&3), first
remove the existing battery before inserting the new
one, use a screw driver to lift the old battery out if
necessary (4). To insert the battery, gently tilt at an angle
towards the metal contact at the edge of the battery slot.
Ensuring the positive symbol (+) is facing upwards, with
very light pressure, push the battery down (5). Once the
battery is inserted correctly, the LED will flash green. If
installing this device for the first time, complete linking
the Sensor now. Then, replace the spacer, followed
by the rear plastic (6) and affix by turning the screw
clockwise using a flat head screwdriver (7).
When the Smart Sensor starts for the first time, please
allow at least 15 seconds to allow the Sensor run it’s
initial set up to allow for motion detection.
Inserting the battery and mounting
Follow the instructions below to insert the CR2477 coin cell into the device. Then follow the linking instructions to pair your device to your Link Plus. Ensure you mount the Sensor
following the guidelines for optimum performance.
1
5
Mounting on a vertical surface
Using a cross head screw driver, mount the magnetic
base on a flat surface. Gently attach the Sensor to
the magnetic mount ensuring the Fresnel lens is
not upside down. (Looking closely at the Fresnel
lens, the larger rectangular boxes are at the top,
orientation indicated on previous image). Adjust the
viewing angle to suit the environment you wish to
detect movement within.
4
7
6
Detecting Range and Viewing Angle
Recommendation for optimum performance at 6
meters with a 90 degree viewing angle is for the
Sensor to be mounted at 1.5 meter height.
The sensitivity of the Sensor can be adjusted in
the Lightwave app. Please be aware that when
you ‘save’ your settings, the device will then be
updated with the new sensitivity setting when
next triggered.
The Lightwave app now has a motion automation
to allow for easier set-up. The ‘IF - DO’
automation can also still be used.
2 & 3