5. Software Control – Using Lightware Device Controller
HDMI20-OPTC series – User's Manual
36
5.8.1. The Event Editor
Press the
Edit
button in the desired Event line to open the Event editor window.
7
1
2
4
5
6
8
3
1
Event header
The name of the Event is displayed. Type the desired name and press the Set
name button. The Event can be cleared by the Clear button. Use the tick mark
to enable/disable the Event.
2
Condition header
If the condition is set, the description (white colored text) and the exact LW3
protocol expression (yellow colored text) can be seen. If the advanced mode
was used the description is “Custom condition”.
3
Condition panel
The Wizard, the Advanced or the Link tool is available to set the condition.
The parameters and settings are displayed below the buttons.
4
Condition test
The set condition can be tested to see the working method in the practice.
5
Delay settings
The action can be scheduled to follow the condition after the set time value.
6
Action header
If the action is set, the description (white colored text) and the exact LW3
protocol expression (yellow colored text) can be seen. If the advanced mode
was used the description is “Custom action”.
7
Action panel
The Wizard, the Advanced or the Link tool is available to set the action. The
parameters and settings are displayed below the buttons.
8
Action test
The set action can be tested to see the working method in the practice.
5.8.2. Create or Modify an Event
Wizard Mode
The wizard mode lists the most common conditions and actions, so the
user does not have to look for LW3 nodes and properties.
Step 1.
Click on the
Edit
button of the desired Event; the
Event editor
is
displayed.
Step 2.
The wizard mode is displayed as default. Select the desired
Category
first (e.g. Audio or Video).
Step 3.
Select the desired
Expression
from the drop-down menu. If any
other parameter is necessary to set, it is going to be displayed.
Step 4.
Press the
Apply
button to store the settings of the Condition.
Conditions and actions in wizard mode in the transmitter
Condition
Category
Expression
Ports
General
Select button is pressed
OPT link state changes to Connected
OPT link state changes to Disconnected
Video
Signal is detected on a port
I1, I2, O1, O2
Signal is not detected on a port
I1, I2, O1, O2
Signal type changes to DVI
I1, I2, O1, O2
Signal type changes to HDMI
I1, I2, O1, O2
Signal type changes to Undefined (no
signal)
I1, I2, O1, O2
Action
Category
Expression
Input
Output
Video
Switch input to output
I1, I2
O1, O2
Enable autoselect on output
O1, O2
Disable autoselect on output
O1, O2
Mute input
I1, I2
Mute output
O1, O2
Unmute input
I1, I2
Unmute output
O1, O2
Port
Message
RS-232
Send RS-232 message
P1
Source EDID Destination EDID
EDID
Switch EDID
F1-146
E1, E2
D1-2
U1-14