5
Error Codes
Press button M to enter menu setting screen, then press button B to select
Parameters. Press push button E to enter the Parameter screen (Figure
4). Select Fault Info and press button E again. Press button A or B to scroll
up/down to check the error codes. To return to home screen - press button
M.
Error Codes
LE
System Error
TEMP
EB is overheating
PFC
PFC Control is faulty
BUCK
Voltage Control has troubles
UVLO
Input Voltage is too low
LAMP
Problems with lamp head / lamp defect
Working Parameters Reference
Supply Voltage
170 - 250V
Output Voltage
4000W – 180 - 200V
2500W – 100 - 110V
Output Current
4000W – 20 - 22A
2500W – 22 - 25A
Input Current
13 - 24A
PFC Voltage
350 - 370°C
Working temperature
40 - 80°C
Figure 3 - Menu Screen