background image

 
                               

 

 

 

 

Page 

of 

 

 

 

 

 

 

 

 

 

 

 

 

FXLE1530W LED FIXTURE 

 

Version 1.0  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

      12/01/2020 

www.lightronics.com 

Lightronics 

Inc. 

        509 

Central 

Drive, 

Virginia 

Beach, 

VA 

 

23454         

 

 

757 

486 

3588

 

 
DMX-KEEP: ON/OFF  

 

The DMX-KEEP mode determines the characteristic of 
the fixture upon the loss of the DMX input signal. The 
LED array will either turn on or off based on the DMX-
KEEP setting when DMX signal is lost.  

 
BK-LIGHT: ON/OFF 

 

The backlight for the LCD display remains on at all 
times if this function is set to ON. When Backlight is set 
to OFF, then the backlit display will turn off 30 seconds 
after the last button push on the control panel.  
 

NOW TEMP 

 

Provides operating temperature in ºC. 

 
MAINTENANCE AND REPAIR

 

 
TROUBLESHOOTING 

 

Fixture will not power up. 

  Check that you have power applied to the 

unit. 

  Check the fuse located on the back panel of 

the fixture.  

 
Unable to control fixture. 

  Check that the LCD display currently 

indicates “DMX-addr”. 

  Check the LCD display on the fixture, if there 

is a V after the DMX value, a valid DMX 
signal is present. If an ‘x’ is showing, then a 
valid DMX signal is not present. 

  Verify that the fixture is properly addressed. 

  Check the DMX control cable for continuity 

and polarity. 

  Remove the fixture from the DMX chain and 

all other DMX devices.  

  Check the address settings or patch at the 

controller. 

 

 

CLEANING 

 

DISCONNECT THE POWER CORD BEFORE 
HANDLING THE UNIT.

 

 

A mild detergent can be used sparingly if needed. 
Apply to cloth first, do not apply detergents directly to 
fixture. Do not use chemicals or solvents when 
cleaning the fixture.  Ensure that the unit is dry before 
use. 

 
REPAIR 

 

The only FXLE1530W user serviceable part is a 5 mm 
x 20 mm externally accessible fuse on the rear panel. 

 
DISCONNECT THE POWER CORD BEFORE 
CHECKING OR REPLACING THE FUSE. 

 

Replace fuse ONLY with 5.0 Amp, 250VAC, fast acting 
fuse. Use a #2 Phillips screwdriver. Use caution to not 
overtighten. 
 

 
 
 
 
 

 
Internal service on the unit by other than Lightronics  
authorized agents will void the warranty. 

 

If service is required, contact the dealer from whom 
you purchased the item, or contact the Lightronics, 
Service Department, 509 Central Drive, Virginia Beach, 
VA 23454.  Tel: 757 486 3588. 
 

 

FXLE1530W

 

10

 

Foot

 

20

 

Foot

 

30

 

Foot

 

 

Beam

 

(ft.)

 

FC

 

Lux

 

Beam

 

(ft.)

 

FC

 

Lux

 

Beam

 

(ft.)

 

FC

 

Lux

 

19°

 

3

 

748

 

7940

 

6

 

186

 

1970

 

9

 

83

 

900

 

26°

 

3.75

 

510

 

5570

 

7.5

 

125

 

1342

 

11.5

 

57

 

623

 

36°

 

6

 

210

 

2320

 

12

 

56

 

605

 

19

 

26

 

282

 

50°

 

7.25

 

165

 

1775

 

14

 

43

 

462

 

23

 

19

 

207

 

DANGER DO NOT OPEN UNIT  

RISK OF ELECTRIC SHOCK 

RISK OF FIRE 

PHOTOMETRIC CALCULATIONS 