Page
3
of
4
FXLD1012C4I LED FIXTURE
Version 0.1
OWNERS MANUAL
02/15/2012
www.lightronic.com
Lightronics
Inc.
509
Central
Drive
Virginia
Beach,
Va
234354
757
486
3588
MASTER /SLAVE OPERATION
The FXLD1012C4I can operate in a Master/Slave
mode where one of the units can synchronize up to 4
other units.
Connect the units together using the DMX IN and
DMX OUT connectors. Set the unit to be the Master
in one of the modes above. Use the
Slave
menu to set
the others to consecutive numbers 1 thru 4 as needed.
MAINTENANCE AND REPAIR
TROUBLESHOOTING
Check that you have power applied to the unit.
Check the fuse.
Check the DMX control cable.
Check the address settings of the unit and the
controller.
REPAIR
The only FXLD1012C4I user serviceable part is a
externally accessible fuse.
DISCONNECT THE UNIT FROM POWER BEFORE
CHECKING OR REPLACING THE FUSE.
Replace the fuse
ONLY
with a 5mm x 20mm 2.0
Amp, 250VAC, fast blow fuse.
Internal service on the unit by other than Lightronics
authorized agents will void the warranty. If service is
required, contact the dealer from whom you purchased
the item, or contact the Lightronics, Service
Department, 509 Central Drive, Virginia Beach, VA
23454. Tel: 757 486 3588.
PHOTOMETRIC CHARACTERISTICS
Distance Illuminance Beam Diam.
(ft)
(Lux)
(ft)
10
917
6
20
230
12
30
112
17
CAUTION DO NOT OPEN UNIT
RISK OF ELECTRIC SHOCK
RISK OF FIRE