background image

Job Information 

Type:

Lightolier 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2008 Philips Group • 

SL110B.pdf

Canlyte 

www.canlyte.com

3015 Louis-Amos, Lachine, Québec  H8T 1C4 • (514) 636-0670 • (514) 636-0460

KUBIK 1.0 

SL110B

Page 4 of 5 

Bare Lamp Stand-Off Unit

1-28W T5 Linear

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

312 

312 

312 

312 

312

316 

313 

311 

309 

304

15 

284 

279 

290 

303 

311

25 

235 

236 

264 

295 

312

35 

179 

191 

232 

281 

309

45 

120 

141 

203 

265 

308

55 

 61 

93 

172 

248 

299

65 

 33 

52 

145 

232 

287

75 

 22 

34 

120 

218 

278

85 

 13 

27 

102 

203 

265

90 

  0 

21 

90 

189 

253

95 

20 

97 

198 

260 

105 

  0 

17 

97 

196 

258

115 

  0 

11 

75 

187 

252

125 

  0 

 9 

19 

82 

134

135 

  0 

 0 

 0 

 5 

27

145 

  0 

 0 

 0 

 0 

 0

155 

  0 

 0 

 0 

 0 

 0

165 

  0 

 0 

 0 

 0 

 0

175 

  0 

 0 

 0 

 0 

 0

180 

  0 

 0 

 0 

 0 

 0

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

537 

537 

537 

537 

537

536 

533 

538 

544 

535

15 

496 

502 

528 

552 

556

25 

436 

453 

496 

541 

554

35 

362 

387 

446 

502 

526

45 

274 

310 

380 

447 

480

55 

194 

233 

307 

375 

418

65 

116 

163 

242 

301 

344

75 

 50 

94 

162 

194 

218

85 

  8 

32 

50 

49 

57

90 

  0 

11 

17 

11 

14

95 

  0 

 4 

11 

13 

21

105 

  0 

 8 

19 

19 

40

115 

  0 

12 

19 

28 

50

125 

  0 

15 

21 

33 

47

135 

  0 

 7 

22 

35 

41

145 

  0 

 5 

20 

30 

38

155 

  0 

 0 

12 

25 

28

165 

  0 

 1 

 3 

 8 

 9

175 

  3 

 1 

 2 

 1 

 0

180 

  2 

 2 

 2 

 2 

 2

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 33.2

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 26.5

Room Cavity Ratio

Room Cavity Ratio

ZONE 

LUMENS 

% LAMP 

% LUMINAIRE

0-30 

235 

9.05 

15.68

0-40 

383 

14.75  

25.55

0-60 

697 

26.81 

46.50

0-90 

1110 

42.69 

74.05

40-90 

726 

27.94 

48.43

60-90 

412 

15.88 

27.48

90-180 

389 

14.96 

25.95

0-180 

1499 

57.65 

100.00

ZONE 

LUMENS 

% LAMP 

% LUMINAIRE

0-30 

428 

16.41 

23.66

0-40 

705 

27.04 

38.98

0-60 

1271 

48.72 

70.24

0-90 

1703 

65.25       

94.07

40-90 

997 

38.21       

55.09

60-90 

431       

16.53       

23.83

90-180 

107        

4.11        

5.93

0-180 

1810       

69.36      

100.00

DISTRIBUTION

DISTRIBUTION

CANDLEPOWER CURVE

CANDLEPOWER CURVE

Performance

CANDLEPOWER

CANDLEPOWER

RePoRT No: C9882

CAT. NO: SL110B281A/SL002ALG

1 x 28W T5 at 2610 Lumens

Efficiency: 57.7 % 

Candela at Nadir: 312cd

RePoRT No: C9930

CAT. NO: SL110B281A/SL002C

1 x 28W T5 at 2610 Lumens

efficiency: 69.4 %

 

Candela at Nadir: 537cd

400

300

200

600

500

400

0    .65  .65  .65  .65  .62  .62  .62  .62  .56  .56 

.56

1    .58  .55  .52  .49  .55  .52  .49  .47  .47  .44 

.42

2    .52  .47  .42  .39  .49  .44  .40  .37  .40  .37 

.34

3    .47  .41  .36  .32  .45  .39  .34  .31  .35  .31 

.28

4    .43  .36  .31  .27  .41  .34  .30  .26  .31  .27 

.24

5    .39  .32  .26  .22  .37  .30  .25  .22  .27  .23 

.20

6    .36  .28  .23  .19  .34  .27  .22  .19  .24  .20 

.17

7    .33  .25  .20  .17  .32  .24  .20  .16  .22  .18 

.15

8    .31  .23  .18  .14  .29  .22  .17  .14  .20  .16 

.13

9    .28  .21  .16  .12  .27  .20  .15  .12  .18  .14 

.11

10   .26  .19  .14  .11  .25  .18  .14  .11  .16  .13 

.10

  0  .82  .82  .82  .82  .79  .79  .79  .79  .75  .75   .75 

  1  .74  .71  .68  .66  .72  .69  .67  .64  .65  .63   .61 

  2  .68  .62  .57  .53  .66  .60  .56  .52  .57  .54   .51 

  3  .62  .55  .49  .45  .60  .53  .48  .44  .51  .46   .43 

  4  .57  .48  .42  .38  .55  .47  .42  .37  .45  .40 

.36

  5  .52  .43  .36  .32  .50  .41  .36  .31  .40  .34 

.31

  6  .47  .38  .32  .27  .46  .37  .31  .27  .35  .30 

.26

  7  .44  .34  .28  .24  .42  .33  .28  .23  .32  .27 

.23

  8  .40  .30  .25  .20  .39  .30  .24  .20  .29  .23 

.20

  9  .37  .28  .22  .18  .36  .27  .21  .17  .26  .21 

.17

 10  .34  .25  .19  .16  .33  .24  .19  .15  .23  .18 

.15

Lightolier is a Philips group brand

Summary of Contents for SL110B

Page 1: ... www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2008 Philips Group SL110B pdf Canlyte www canlyte com 3015 Louis Amos Lachine Québec H8T 1C4 514 636 0670 514 636 0460 Job Information Type Job Name Cat No Lamp s Notes Accessories Options Cat No Description Finish SL002ALG Spiral Louver Textu...

Page 2: ... 72 White Mounts to a 3 76mm or 4 102mm octagonal outlet box Kit includes one 0 024 0 6mm thick 5 127mm round steel canopy and one 0 06 1 5mm thick 1 2 13mm dia seamless steel stem available in 4 different lengths and two decorative cylinder head screws Complete installation of Power Feed Stem Kit Field cuttable re thread stem 1 4 18 NPS Comes with 5 pre assembled wires 10 Amps max Cat No Finish S...

Page 3: ...one 46 3 16 1173mm long extruded aluminum channel and cover two solid aluminum multi function blocks as a wireway plug inserts and wire connectors 46 3 16 1173 mm Cat No Finish Invisible Coupler SL003G Zinc plated Invisible coupler for joining two Kubik 1 0 units together mechanically or and electrically Recommended for direct surface mounting Comes with 4 wires 18 AWG 10 Amps max Cat No Finish 5 ...

Page 4: ...ITY REFLECTANCE 20 80 70 50 Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS 26 5 Room Cavity Ratio Room Cavity Ratio ZONE LUMENS LAMP LUMINAIRE 0 30 235 9 05 15 68 0 40 383 14 75 25 55 0 60 697 26 81 46 50 0 90 1110 42 69 74 05 40 90 726 27 94 48 43 60 90 412 15 88 27 48 90 180 389 14 96 25 95 0 180 1499 57 65 1...

Page 5: ...yte com 3015 Louis Amos Lachine Québec H8T 1C4 514 636 0670 514 636 0460 KUBIK 1 0 SL110B Page 5 of 5 Bare Lamp Stand Off Unit 1 28W T5 Linear Pattern SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL110A281A SL003G SL003G SL003G SL003F4 SL110A281A SL003K SL003J SL003M SL003H SL003H SL003H SL004N SL003H SL004N SL003J SL003J ...