0’
1’
2’
3’
4’
5’
0’
1’
2’
3’
4’
5’
Lighting Data 2-54W T5 High Output
1’
198
176
118
60
28
14
2’
158
142
90
52
24
10
3’
103
94
69
41
22
10
4’
68
63
49
33
20
12
5’
40
38
30
22
14
8
6’
26
25
21
16
12
8
7’
17
16
14
11
8
6
8’
11
11
10
8
6
5
9’
8
8
7
6
5
4
263
258 263
209
206 209
149
148 149
116
116 116
71
71
71
56
56
56
38
38
38
27
27
27
22
22
22
218 127 218
168 106 168
112
84 112
87
74
87
49
44
49
41
38
41
27
26
27
19
18
19
16
15
16
Footcandles on Wall
Track 3 Feet From Wall
Single Unit
Multiple Units
4’
6’
3’
Distance From Ceiling
45˚
EXAMPLE: With track located 4’ from wall and multiple units spaced
6’ on center and aimed 45˚ from horizontal, the illumination on wall 4’
from ceiling will be 79 f.c. beneath units and 70 f.c. between units.
1’
113
101
71
39
17
6
2’
114
104
77
47
25
12
3’
87
80
62
40
24
13
4’
63
59
47
34
22
13
5’
46
44
36
27
19
13
6’
31
30
25
20
14
10
7’
22
21
18
15
11
8
8’
16
15
13
11
9
7
9’
11
11
10
8
7
6
145
143 145
164
163 164
136
135 136
112
112 112
93
93
93
66
66
66
50
50
50
41
42
42
31
32
32
123
106 123
136
123 136
110
103 110
91
88
91
77
75
77
54
53
54
41
40
41
35
34
35
26
26
26
114
76 114
123
92 123
97
79
97
79
70
79
66
62
66
46
43
46
35
34
35
30
29
30
23
22
23
Track 4 Feet From Wall
Single Unit
Multiple Units
4’
5’
6’
4’
Distance From Ceiling
45˚
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
Footcandles on wall:
Beam Center
Beam Center
231 184 231
180 150 180
124 112 124
97
92
97
57
55
57
47
46
47
31
31
31
22
22
22
18
18
18
5’
0’
1’
2’
3’
4’
5’
1’
81
75
59
40
25
15
2’
83
77
61
42
27
16
3’
75
70
57
41
28
18
4’
55
52
43
32
23
15
5’
42
40
34
27
19
14
6’
33
31
27
22
17
12
7’
25
24
21
17
14
11
8’
18
17
15
13
10
8
9’
13
13
12
10
9
7
140
139 140
147
147 147
143
143 143
109
109 109
89
89
89
76
76
76
62
62
62
46
46
46
39
39
39
115
109 115
121
116 121
118
115 118
89
87
89
73
71
73
62
61
62
51
50
51
37
37
38
32
32
32
102
86 102
107
93 107
104
94 104
76
71
76
62
59
62
53
51
53
44
42
44
32
31
32
27
27
27
Track 5 Feet From Wall
Single Unit
Multiple Units
4’
5’
6’
5’
Distance From Ceiling
45˚
Beam Center
Lamp Information:
2 X 54W T5 High Output
Mini Bi-Pin Fluorescent (9476)
1 x 54W T5 High Output
Mini Bi Pin Fluorescent (9477)
One Lamp, with louver,
aimed 45˚ down.
Two Lamps, without louver,
aimed 45˚ up.
Two Lamps, with louver,
aimed 45˚ down.
0˚ 30˚
90˚
60˚
180˚ 150˚
120˚
90˚
0˚ 30˚
90˚
60˚
Lytespan
®
Track Lighting System
9476
Page 2 of 2
PowerWash
™
T5 4 Foot Track Mounted 54 Watt High Output Fluorescent
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0902
Job Information
Type: