background image

Lytecaster

®

Recessed Downlighting 

1102TM1

Page 1 of 1

6  3/4 ” Aperture Low Profile 2 Lt. 13W Emergency Fluorescent Frame-In Kit

Features

1. Mounting Frame:

.036" (#20 ga.) galvanized steel. Accommodates all

ceilings up to 1" thick. Low profile 3 7/8" depth including ceiling material and
reflector trim. For ceilings thicker than 5/8", depth from finished ceiling will
be ceiling thickness (max. 1") plus 3 1/4". Push-in/twist-out rotoclips hold
reflector flush to ceiling.

2. Junction Box:

.063" (#14 ga.) galvanized steel. Rated for 8 #12 AWM

through branch circuit wires suitable for 90° C, for end of run 75° C. Quick
release “L” shaped cover for access to wiring. Integral cable clamps permit
attachment of nonmetallic Romex

®

or armored  cable without need of

additional connectors.

3. Mounting Bars:

Die-formed steel, #16 ga. Four bars, 13" long, extend to

27", permit off-center mounting; bars rotate 90° and lock in both directions;
integral poised nailer for wood joists, locking tabs for T-bar runners.

4. Socket Housing:

22 ga. galvanized spring steel; snap-in quick assembly for

precise lamp location.

5. Socket:

Two-pin base, molded thermoplastic; prewired with #18 AWM leads

to 4" x 3 1/2” x 2" junction box.

6. Thermally Protected Ballast:

2 light electromagnetic, encased and potted,

class "P" high power factor. Insulation must be kept 3" away from fixture
sides and wiring compartment and must not be placed above fixture as to
entrap heat.

7. Emergency Power Pack:

Electronic, fully encased and pre-wired nickel

cadmium long life battery, replaceable from below. Meets requirements of
National Electric Code and Life Safety Code. Test switch and charge light
included in easy to install recessed switch box with 4 1/2” diameter matte
white cover plate, 24" long flexible cable; may be installed up to 50 feet from
fixture. One lamp operates at 61% initial output for 90 minutes when power
fails.

Electrical

120V 

277V

HPF  Input Watts 

31

42

Amps 

0.28 

0.17

Minimum starting time is 32° F.

Options & Accessories

Concealed Spline Ceiling Kit: 

1965

- set of (4), 1 1/2” to 2 1/2” Mtg. Ht.

Plaster Ceiling Ring: 

1961

- 7/8" depth for wet plaster ceilings.

Labels

UL (Suitable for Damp Locations), I.B.E.W.

Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.

Frame-In Kit

Reflector Trims   — See Individual Reflector Trim Specification Sheets

Open Downlight

Cone

Baffles

Cross Blade

1102TM1           

HPF 120V

1113TGD

1105T

1132T

1126T

1135T

1102TM2           

HPF 277V

1113TCL

1105TWH

1128T
1178T

Enclosed
Diffusers

Wall

Washer

Romex

®

is a registered trademark of General Cable Industries Inc.

Job Information

Type:

Job Name: 
Cat. No.: 

Lamp(s): 
Notes:

Lightolier 

a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • F0711