background image

Lighting Systems

 

Baselyte-BSL23

Page 3 of 8   

3 Light T8 Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

Mount Type: T-Bar 15/16” (On-Grid)*

Mount Type: T-Bar 9/16” (On-Grid)*

Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13

  4 Conductor

BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14

  7 Conductor

BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17

Non-Power Mount

BSLM6102N

BSLM6104N

BSLM6108N

BSLM6112N

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

 
 

*

Note

Standard T-bar mounts are currently not available for tegular tile ceilings,  

 

however certain tegular tile / T-bar combinations may be supported by the use of the  

 

slot-grid mount. For more information, please consult factory.

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13

  4 Conductor

BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14

  7 Conductor

BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17

Non-Power Mount

BSLM6202N

BSLM6204N

BSLM6208N

BSLM6212N

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13

  4 Conductor

BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14

  7 Conductor

BSLM6302P17 BSLM6304P17 BSLM6308P17 BSLM6312P17

Non-Power Mount

BSLM6302N

BSLM6304N

BSLM6308N

BSLM6312N

Mounting Options

Summary of Contents for Lighting Systems Baselyte-BSL23

Page 1: ...at finish 3 Lamping three T8 lamps 4 Configuration 4 8 and 12 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish Cust...

Page 2: ...85 0 0 0 0 0 75 0 0 0 0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 5...

Page 3: ...d aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stra...

Page 4: ...h 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM311...

Page 5: ...BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 str...

Page 6: ...Bodine standard B70A Type E Chloride high performance C1400 Type P Bodine high performance B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the b...

Page 7: ...g with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture center outer switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to f...

Page 8: ...A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire Type S 2cct w 2cct thru wire 2 Circuit A B Switching alternate 4 sections w...

Reviews: