background image

Lighting Systems

 

Baselyte-BSL21

Page 6 of 7   

 Light T8 Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Wiring Options: 1 Circuit

1 Circuit with Emergency Circuit/Night Light (EC/NL)

One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal 
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.

Type 3: 

cct. w/EC/NL

All lamps wired on one circuit.

1 Circuit

Type 5: 

Chloride standard 

C700A

Type M

: Bodine standard 

B70A

Type E: 

Chloride high performance 

C400

Type P: 

Bodine high performance 

B50

All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected 
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by 
installer. Leads for both normal circuit and battery pack are wired to fixture ends.

1 Circuit with Emergency Battery Pack (EM)

One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery 
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together 
or wire separately if controlled independently. Leads for normal circuit, EC/NL circuit and EM wired 
to fixture ends. All lamps in EC/NL section to be wired together. 

1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack

Type J: 

Chloride standard 

C700A

%#.,

%-

%#.,%-

Type 1: 

cct.

Type 8:

 cct. w/cct. thru wire

Type H: 

cct. w/2cct. thru wire

Type 7: 

cct. w/dimming

Summary of Contents for Lighting Systems Baselyte-BSL21

Page 1: ...4 Configuration 4 8 and 12 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory...

Page 2: ...0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE 50...

Page 3: ...d aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stra...

Page 4: ...h 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM311...

Page 5: ...BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 str...

Page 6: ...ormance C1400 Type P Bodine high performance B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wir...

Page 7: ...th Emergency Battery Pack EM Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire T...

Reviews: