background image

Lighting Systems

 

Baselyte-BSL21

Page 4 of 7   

 Light T8 Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod)

Mount Type: T-Bar Variable Position

Mount Type: Support or Open-Joist Ceiling 

Supension Length

Non-Power Mount

1-Power Mount

2-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13

  4 Conductor

BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14

2-Power Mount

  3 Conductor

BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23

Non-Power Mount

BSLM2102N

BSLM2104N

BSLM2108N

BSLM2112N

Supension Length

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM5102P13 BSLM5104P13 BSLM5108P13 BSLM5112P13

  4 Conductor

BSLM5102P14 BSLM5104P14 BSLM5108P14 BSLM5112P14

  7 Conductor

BSLM5102P17 BSLM5104P17 BSLM5108P17 BSLM5112P17

2-Power Mount

  3 Conductor

BSLM5102P23 BSLM5104P23 BSLM5108P23 BSLM5112P23

Non-Power Mount

BSLM5102N

BSLM5104N

BSLM5108N

BSLM5112N

Supension Length

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13

  4 Conductor

BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14

  7 Conductor

BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17

2-Power Mount

  3 Conductor

BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23

Non-Power Mount

BSLM3102N

BSLM3104N

BSLM3108N

BSLM3112N

Non-Power Mount

1-Power Mount

2-Power Mount

Non-Power Mount

1-Power Mount

2-Power Mount

•   Meets UBC, OSHPD and DSA seismic requirements 
•   Canopy: Diameter of 5 /4“x 3/4” (power)
•   Cable: 7x7 stranded aircraft cable
•   Tile cut-out hole: Diameter of 2 /2” (power) or 3/4” (non-power)
•   J-Box: Integral J-Box supplied
•   /4 - 20 all thread rod (supplied by others)
•   Fully vertically adjustable at fixture

• 

  Meets UBC, OSHPD and DSA seismic requirements

•  

 Canopy: Diameter of 5 

/4

“x 

3/4

(power)

•   Cable: 7x7 stranded aircraft cable
•   Versatile mount, fully adjustable to accomodate open sloped ceilings
•   J-Box: 4” octogonal box (supplied by others)
•   Fully vertically adjustable at fixture

•   Meets UBC, OSHPD and DSA seismic requirements
•   Canopy: Diameter of 3“x 7/32”
•   Cable: 7x7 stranded aircraft cable
•   Tile cut-out hole: Diameter of 2 /4”
•   Aligned by T-bar and secured to structure 
•  J-Box 4” square (supplied by others)
•   Fully vertically adjustable at fixture
•   Adjusts to both ” and  /2” high T-bar systems
 
 

*Note

: Supports 5/6”, 9/6” and slot grid ceiling types.

Summary of Contents for Lighting Systems Baselyte-BSL21

Page 1: ...4 Configuration 4 8 and 12 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory...

Page 2: ...0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE 50...

Page 3: ...d aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stra...

Page 4: ...h 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM311...

Page 5: ...BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 str...

Page 6: ...ormance C1400 Type P Bodine high performance B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wir...

Page 7: ...th Emergency Battery Pack EM Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire T...

Reviews: