Lytecel Recessed Fluorescent

LCS6G20LW232

Page 2 of 2

For Continuous Row Mounting, 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,

Air Return/Static, 2 Lamp T8, IES RP1 For VDT AreaS

Lightolier

a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company

Section 2/Folio G07-42

Job Information

Type:

Ordering Information

Explanation of Catalog Number. Example: LCS6G20LW232120SO

Options/Accessories

Access Plate

: Top Wiring access plate is shipped with fixture as standard. When

access plates are required in advance for wiring convenience, specify separately.
Order Catalog Number:

ACP5 CSP

.

Coupler/Clamp

: (Set of 2) Required for beginning of rows.

Order Catalog Number:

LC85 CLAMP

(for G or T type)

End Trim

: Required at beginning and end of rows. For every row order (2).

Order Catalog Number:

LC6 END TRIM

.

Electrical/Wiring Options

: Consult factory.

EM Pack

or

Dimming Ballast

: Consult factory.

Fusing

: Internal fast-blow fusing. Suffix:

GLR

.

Internal slow-blow fusing. Suffix:

GMF

.

Chicago Plenum:

Suffix:

CP

.

Specifications

Performance:

In an installation of 2 lamp 32W semi-specular luminaires in a

room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U.
shall not be less than .53 with a spacing to mounting ratio of 1.3 perpendicular
to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort
probability) shall not be less than 91 either crosswise or lengthwise and the
candela value between 55° and 90° in the 0° to 90° planes shall not exceed
4631. Candelas at Nadir (0°) not to exceed 1234.

Specifications (continued)

Air Handling

–(LCA only) Side air passages for air return.

Materials: Chassis parts

are die-formed cold rolled steel.

Louver:

Pre-anodized aluminum (Coilzak

®

or equal).

Finish: Louver

—specular or semi-specular low iridescence pre-anodized

reflector sheet.

Reflector:

White baked polyester enamel.

Chassis exterior

black baked polyester enamel.

Electrical:

Thermally protected class “P” ballast C.B.M. approved, non PCB. If

K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org

LC:

Lytecel 6"

Continuous

Louver

Appearance

6

Fixture

Width

20

Number of

Cells:

1 row of

20 cells

Louver Finish:

L

=Low

Iridescence
Semi-specular

P

=Low

Iridescence
Specular

W

2

Lamp

Quantity:

(By others)

2

=2 Lamp

32

Lamp Fixture

Length:

32

=T8

(Nominal 48")

Ballast Type:

<

20THD

<

10THD

2 Lamp Elec. T8

SO*

H

I

*

*Instant Start Standard
Other dimming options, consult factory.

NOTE:

For

T8 UNV

, you must use

H

I

Ballast Code.

DA

=DALI digital addressable dimming.

Options:

Add appropriate

suffix to catalog

no, ie: (GLR)

Voltage:

120, 277 or

UNV

=120-277

0.0

45.0

90.0

FLUX

0

1234

1234

1234

5

1252

1300

1306

122

15

1207

1280

1287

356

25

1100

1182

1215

542

35

962

1020

1058

643

45

799

835

926

650

55

478

457

393

392

65

34

58

39

53

75

4

6

10

7

85

1

2

3

2

90

1

1

1

Model No. LCS6G20LW232120SO

LER = FP - 38.6

IW - 78.0

BF - 1.1

Comparative yearly lighting energy cost per

1000 lumens = $6.22

Report Number: G1206011
Catalog Number: LCS6G20LW232120SO
Lamp: F32 T8
Luminaire: 6" wide Troffer with semi-
specular louver and white reflector.
Ballast: Advance REL-2P32-SC
Report is based on 2850 Lumens per lamp.

Efficiency: 48.6%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

47.943

5.816

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

6279.

6562.

7277.

55

4631.

4427.

3807.

65

316.

763.

513.

75

86.

129.

215.

85

64.

128.

191.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

54 53 51 49 48 47 48 47 46

2

50 47 45 45 43 41 43 42 40

3

47 43 39 41 38 36 39 37 35

4

43 38 35 37 34 32 36 33 31

5

40 35 31 33 30 28 32 30 28

6

37 32 28 30 27 25 30 27 25

7

35 29 25 28 25 22 27 24 22

8

32 26 23 25 22 20 25 22 20

9

30 24 21 24 20 18 23 20 18

10 28 22 19 22 19 16

2

18 16

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1021

17.9

36.9

0

0-

0

40

1664

29.2

60.1

0

0-

0

60

2707

47.5

97.7

0

0-

0

90

2769

48.6

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2769

48.6

100.0

ZONAL LUMEN SUMMARY

0.0

45.0

90.0

FLUX

0

1373

1373

1373

5

1287

1314

1304

125

15

1244

1345

1368

370

25

1149

1246

1264

566

35

1018

1079

1088

681

45

849

926

1005

711

55

579

520

440

441

65

1

52

32

39

75

1

4

9

6

85

1

2

3

3

90

1

1

2

Model No. LCS6G20PW232120SO

LER = FP - 40.9

IW - 78.0

BF - 1.1

Comparative yearly lighting energy cost per

1000 lumens = $$5.87

Report Number: G1206012
Catalog Number: LCS6G20PW232120SO
Lamps: F32 T8
Luminaire: 6" wide Troffer with specular
louver and white reflector.
Ballast: Advance REL-2P32-SC
Report is based on 2850 Lumens per lamp.

Efficiency: 51.6%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

47.943

5.816

CANDELA DISTRIBUTION

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

58 56 54 53 51 50 51 50 49

2

54 50 48 48 46 44 46 44 43

3

50 45 42 43 40 38 42 39 37

4

46 41 37 39 36 33 38 35 33

5

43 37 33 35 32 29 34 31 29

6

40 33 29 32 29 26 31 28 26

7

37 30 26 29 26 23 29 26 23

8

34 28 24 27 23 21 26 23 21

9

32 26 22 25 21 19 24 21 19

10 30 24 20 23 20 17 22 19 17

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1061

18.6

36.1

0

0-

0

40

1742

30.6

59.2

0

0-

0

60

2895

50.8

98.4

0

0-

0

90

2942

51.6

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2942

51.6

100.0

ZONAL LUMEN SUMMARY

Reflector:

W

=White

Mounting Height

Lengthwise Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

8.5 10 8.5 10

8.5 10 8.5 10

30x30

90 85 77 70

88 83 76 68

40x40

90 85 82 76

90 85 82 73

60x30

90 85 80 75

88 83 79 73

60x60

91 86 82 79

91 87 84 78

100x100

91 87 82 78

92 90 87 82

TYPICAL V.C.P.'s

Mounting Height

Lengthwise Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

8.5 10 8.5 10

8.5 10 8.5 10

30x30

85 76 70 69

88 80 76 67

40x40

85 76 72 72

90 84 81 73

60x30

85 76 72 74

89 80 77 69

60x60

85 78 73 74

91 86 83 76

100x100

86 78 73 74

92 88 86 81

TYPICAL V.C.P.'s

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

6672.

7277.

7898.

55

5609.

5038.

4263.

65

13.

684.

421.

75

21.

86.

193.

85

64.

128.

191.

LUMINANCE DATA IN CANDELA/SQ. METER

Body Style:

A

=Air Return

S

=Static

Ceiling Type:
G

= 9/16" or

15/16"Grid

T

= Slot Grid

Standard Lytecel

LC

For NYC Code – Local 3 Manufactured

LN

Reviews: