4. Using the wire provided in parts bag; pass approximately half

the length of each black, white and green wire through opening
in back of FIXTURE HOUSING. (Fig. 2)

5. Position LINEAR ADAPTER COVER over back of FIXTURE HOUSING

allowing two THREADED STUDS to pass through mounting holes
surrounding KNOCK-OUT OPENING. 

Caution

:  Make certain not to pinch wires between FIXTURE

HOUSING and LINEAR ADAPTER. Secure LINEAR ADAPTER in
place by placing LOCK WASHERS and HEX NUTS (from front of
fixture housing) over threaded STUDS and fully tighten.

6. Carefully pull supply wires from outlet box through center

KNOCK-OUT HOLE and mount FIXTURE HOUSING to outlet box
using outlet box screws (provided with outlet box). 

Note

: In addition to outlet box mounting, it is also recommended

to use AUXILIARY MOUNTING HOLES at each end of 
FIXTURE HOUSING. (Fig. 1) Use appropriate mounting 
hardware for the wall surface (i.e.: wood screws, toggle
bolts, molly screws, etc.).

7. In second adjoining FIXTURE HOUSING, remove SMALL 

DIAMETER KNOCK-OUT in the  end closest to first FIXTURE and
snap PLASTIC BUSHING into opening.

8.   Pass the other half of black, white and green wires through

opening.

9. Position second FIXTURE HOUSING over end of LINEAR ADAPTER

allowing MOUNTING STUDS on ADAPTER to pass through
MOUNTING HOLES in back of FIXTURE HOUSING. Secure FIXTURE
HOUSING to wall surface using appropriate mounting hardware
for the wall surface (i.e.: wood screws, toggle bolts, molly
screws, etc.). 

Note

: If additional FIXTURES are to be installed; follow steps 3

through 5 prior to mounting second FIXTURE HOUSING. 

Secure LINEAR ADAPTER in place by placing LOCK WASHER
and HEX NUT (from front of fixture housing) over threaded
STUDS and fully tighten.

10. Make electrical connections: FIXTURE HOUSING containing 

supply wires (in coming power); connect black fixture lead and
black wire from LINEAR ADAPTER to black (hot) supply lead;
white fixture lead and white wire from LINEAR ADAPTER to
white (neutral) supply lead. Green fixture wire and green LINEAR
ADAPTER wire are ground wires and must be connected to a
ground screw or ground lead within outlet box. Use wire nuts
(local hardware item) to make connections. Carefully push all
wire connections through center opening making certain all 
connections are inside of outlet box.

11. Using WIRE NUTS (provided with fixture) connect second fixtures

black lead to black LINEAR ADAPTER lead; white fixture lead to
white LINEAR ADAPTER lead; green fixture lead (ground) to
green LINEAR ADAPTER lead. Repeat procedure if other fixtures
are installed in continuous run.

12. Re-install REFLECTOR by placing two TABS on REFLECTOR into

SLOTS in FIXTURE HOUSING and pivot REFLECTOR back until
HOLES in REFLECTOR aligns with HOLES in FIXTURE HOUSING.
Secure REFLECTOR in position by re-installing two REFLECTOR
MOUNTING SCREWS. Repeat procedure for remaining FIXTURES
in run.

Fig. 2
BACK-VIEW OF FIXTURE HOUSING

SMALL DIAMETER 

KNOCK-OUTS

SMALL DIAMETER 

KNOCK-OUTS WITH 

PLASTIC BUSHING

AUXILIARY 

MOUNTING

HOLES

SLOT

SPRING CLIP

LOCK

WASHER

HEX

NUT

CENTER
KNOCK-OUT

WIRE: 
BLACK, WHITE, & GREEN 

(

provided with fixture

)

THREADED
STUD

LINEAR ADAPTER
COVER

FIXTURE 
HOUSING

KNOCK-OUT
SLOTS

Fig. 3

SLOT

DIFFUSER DOOR

DRAW
BOLT

ALLEN

SCREW

ALLEN

WRENCH

SPRING
CLIP

FINGER 
NOTCH

NOTCH

MOUNTING
BOSS