background image

Job Information 

Type:

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

 F7000-21

1BHFPG

'4FSJFT-JHIU54PMJE8BMM.PVOU

E0808

CANDLEPOWER

ZONE

0

22

45

67

90

DEG.

CANDELAS

90

0

0

0

0

0

95

69

79

93 120

53

105

434 454 461 374 243

115

814 780 673 598 439

125

949 925 875 775 621

135

1113 1094 1037 911 788

145

1218 1191 1119 1022 926

155

1226 1204 1159 1097 1034

165

1206 1195 1175 1141 1108

175

1160 1157 1157 1151 1143

180

1139 1139 1139 1139 1139

Performance

CANDLEPOWER CURVE

1200

900

600

300

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

REPORT NO.: ITL54694.IES
LAMPS: 1-F54T5
LUMENS: 5000 each
EFFICIENCY: 75.3%
CAT. NO.: F7511WH214

DISTRIBUTION

Zone

Lu

m

ens

% La

m

p

%Lu

m

inaire

0 - 90

0

0.0

0.0

90 - 180

3763

75.0

100.0

0 - 180

3763

75.0

100.0

80%

70%

50%

50 30

10

50

30

10

50 30 10

0

72 72

72

61

61

61

42 42 42

1

62 60

57

53

51

49

36 35 34

2

54 50

47

47

43

40

32 30 28

3

48 43

39

41

37

34

28 26 24

4

42 37

32

36

32

28

25 22 20

5

37 32

27

32

27

24

22 19 17

6

33 27

23

28

24

20

20 17 14

7

30 24

20

25

21

18

18 15 12

8

27 21

17

23

18

15

16 13 11

9

24 19

15

21

16

13

14 11 9

10

22 17

13

19

15

12

13 10 8

20% FLOOR CAVITY REFLECTANCE

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

WALL REFLECTANCE

ROOM

CA

VITY

RA

TIO

Mounting Accessories

Wall Mount End Set
FW7EWH

= White

FW7EAL

= Alu

m

inu

m

Fixture Lengths & Mounting Reflected (Plan View)

20'-3" (617.22c

m

)

16'-3" (495.30c

m

)

12'-3" (373.38c

m

)

8'-3" (251.46c

m

)

4'-3" (129.54c

m

)

2'-8"

(81.28c

m

)

6'-8" (203.20c

m

)

6'-8" (203.20c

m

)

2'-8"

(81.28c

m

)

1'-4"

(40.64c

m

)

6'-8" (203.20c

m

)

1'-4"

(40.64c

m

)

6'-8" (203.20c

m

)

6'-8" (203.20c

m

)

1'-4"

(40.64c

m

)

6'-8" (203.20c

m

)

2'-8"

(81.28c

m

)

1'-4"

(40.64c

m

)

16.00" (40.64c

m

)

3/4"
(1.91c

m

)

1-1/2"
(3.81c

m

)

3/8" (0.95c

m

)

END OF ROW DETAIL

GAP BETWEEN FIXTURES

JOINING DETAIL

Reco

mm

ended 

m

ounting is a single gang outlet box rotated 90 degrees at the

feed point. Re

m

aining 

m

ounting points could be outlet boxes as well, or a couple

of holes per 

m

ounting point spaced 3-1/4” (8.26c

m

) at 1-3/4” (4.45c

m

) above the

botto

m

 of fixture.