Architectural Decorative Vetro Downlight

  D01

Page 2 of 3 

Compact Fluorescent

Certified test report no. 3533FR   

Computed by LSI program **TEST-LITE**

SC(Along) = 1.3, SC(Across) = 1.5 

Prepared For:

Lightolier

 Fall River, MA

 

 250

 500

30°

60°

90°

 100

 375

Calculite 6" Dia. Recessed Horizontal Vetro Downlight,  

Cat.# 8031CL/D6A01

32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.

Universal Ballast #C2642UNVBES(#1)

Candlepower Summary

Angle Along

22.5

45

67.5

Across

LMS

0

408

408

408

408

408

5

410

418

423

422

420

40

10

432

445

452

440

436

15

445

446

439

429

431

123

20

434

427

416

409

413

25

419

393

393

417

416

187

30

384

388

381

391

388

35

326

351

383

396

393

224

40

252

266

299

322

323

45

193

182

174

172

171

150

50

150

141

127

111

111

55

87

79

73

72

73

72

60

41

42

43

44

44

65

36

37

37

38

38

38

70

32

33

33

34

34

75

28

28

29

30

30

31

80

25

26

27

27

26

85

23

24

24

25

24

26

90

20

21

21

21

21

8031CL-D6AO1

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

350

14.60

39.31

0-40

574

23.92

64.42

0-60

796

33.19

89.37

0-90

891

37.14

100.00

40-90

317

13.22

35.58

60-90

94

3.95

10.63

90-180

0

.00

.00

0-180

891

37.14

100.00

**  Efficiency = 37.1%  **

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

10%

Wall

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Ro

om C

av

ity R

at

io

0 .44 .44 .44 .44 .43 .43 .43 .43 .41 .41 .41 .40 .40 .40 .38 .38 .38 .37
1 .41 .40 .39 .37 .40 .39 .38 .37 .37 .37 .36 .36 .35 .35 .35 .34 .34 .33
2 .39 .36 .34 .33 .38 .36 .34 .32 .34 .33 .32 .33 .32 .31 .32 .31 .30 .30
3 .36 .33 .31 .29 .35 .32 .30 .29 .31 .30 .28 .31 .29 .28 .30 .28 .27 .27
4 .34 .30 .28 .26 .33 .30 .28 .26 .29 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .32 .28 .25 .23 .31 .27 .25 .23 .27 .24 .23 .26 .24 .23 .25 .24 .22 .22
6 .30 .26 .23 .21 .29 .25 .23 .21 .25 .22 .21 .24 .22 .20 .23 .22 .20 .20
7 .27 .23 .21 .19 .27 .23 .20 .19 .22 .20 .18 .22 .20 .18 .22 .20 .18 .18
8 .26 .21 .19 .17 .25 .21 .19 .17 .21 .18 .17 .20 .18 .17 .20 .18 .16 .16
9 .24 .20 .17 .15 .23 .19 .17 .15 .19 .17 .15 .19 .16 .15 .18 .16 .15 .14

10 .22 .18 .15 .14 .22 .18 .15 .13 .17 .15 .13 .17 .15 .13 .17 .15 .13 .13

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts =  36.0

Tested According to IES Procedures. Test Distance Exceeds Five  

Times the Greatest Luminous Opening of Luminaire.

Luminance Summary - CD. / SQ. M. 

 

Angle 

Mean CD/SQ M 

 

45 

13825

 

55 

4359

 

65 

4460

 

75 

5694

 

85 

13872

Calculite 6" Recessed Vetro Downlight, Cat.# 8021CL/D6A01

32W G.E. Biax T/E Triple Tube (Lower Position).  

Lumen Rating = 2200 Lms. Universal Ballast #C2642UNVBES

Candlepower Summary

Angle Mean CP LMS.

Angle Mean CP LMS.

0

459

90

20

5

448

44

95

17

15

10

489

100

3

15

526

146

105

2

2

20

524

110

2

25

487

223

115

2

2

30

426

120

2

35

356

222

125

2

2

40

274

130

2

45

178

138

135

2

1

50

85

140

2

55

45

48

145

2

1

60

39

150

2

65

34

34

155

2

1

70

31

160

2

75

27

29

165

2

1

80

24

170

2

85

22

24

175

2

0

90

20

180

2

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

413

18.77

44.29

0-40

634

28.84

68.05

0-60

820

37.32

88.03

0-90

907

41.26

97.35

40-90

273

12.42

29.30

60-90

86

3.95

9.31

90-180

24

1.12

2.65

0-180

932

42.39

100.00

**  Efficiency = 42.4%  **

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

10%

Wall

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Ro

om C

av

ity R

at

io

0 .50 .50 .50 .50 .49 .49 .49 .49 .46 .46 .46 .44 .44 .44 .42 .42 .42 .41
1 .47 .46 .44 .43 .46 .45 .43 .42 .42 .42 .41 .41 .40 .39 .39 .38 .38 .37
2 .44 .42 .40 .38 .43 .41 .39 .37 .39 .38 .36 .38 .36 .35 .36 .35 .34 .34
3 .41 .38 .36 .34 .40 .37 .35 .33 .36 .34 .33 .35 .33 .32 .34 .33 .31 .31
4 .39 .35 .33 .30 .38 .35 .32 .30 .34 .31 .30 .33 .31 .29 .32 .30 .29 .28
5 .37 .33 .30 .28 .36 .32 .29 .27 .31 .29 .27 .30 .28 .27 .29 .28 .26 .26
6 .35 .30 .27 .25 .34 .30 .27 .25 .29 .26 .25 .28 .26 .24 .27 .26 .24 .23
7 .32 .28 .25 .23 .32 .27 .25 .23 .27 .24 .22 .26 .24 .22 .25 .23 .22 .21
8 .30 .26 .23 .21 .30 .25 .23 .21 .25 .22 .20 .24 .22 .20 .24 .22 .20 .19
9 .28 .24 .21 .19 .28 .23 .21 .19 .23 .20 .19 .22 .20 .18 .22 .20 .18 .18

10 .27 .22 .19 .17 .26 .22 .19 .17 .21 .19 .17 .21 .18 .17 .20 .18 .17 .16

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts =  33.0

Certified test report# 3494FR   

Computed by LSI program **TEST-LITE**

SC = 1.0 

Prepared For:

Lightolier

 Fall River, MA 

Tested According to IES Procedures. Test Distance Exceeds Five  

Times the Greatest Luminous Opening of Luminaire.

8021CL-D6AO1

 250

 500

30°

60°

90°

 125