Lightolier is a Philips group brand
Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1108
Architectural Decorative Vetro Downlight
D01
Page 2 of 3
Compact Fluorescent
Certified test report no. 3533FR
Computed by LSI program **TEST-LITE**
SC(Along) = 1.3, SC(Across) = 1.5
Prepared For:
Lightolier
Fall River, MA
250
500
0°
30°
60°
90°
100
375
Calculite 6" Dia. Recessed Horizontal Vetro Downlight,
Cat.# 8031CL/D6A01
32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.
Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle Along
22.5
45
67.5
Across
LMS
0
408
408
408
408
408
5
410
418
423
422
420
40
10
432
445
452
440
436
15
445
446
439
429
431
123
20
434
427
416
409
413
25
419
393
393
417
416
187
30
384
388
381
391
388
35
326
351
383
396
393
224
40
252
266
299
322
323
45
193
182
174
172
171
150
50
150
141
127
111
111
55
87
79
73
72
73
72
60
41
42
43
44
44
65
36
37
37
38
38
38
70
32
33
33
34
34
75
28
28
29
30
30
31
80
25
26
27
27
26
85
23
24
24
25
24
26
90
20
21
21
21
21
8031CL-D6AO1
Zonal Lumens and Percentages
Zone
Lumens
% Lamp
%Luminaire
0-30
350
14.60
39.31
0-40
574
23.92
64.42
0-60
796
33.19
89.37
0-90
891
37.14
100.00
40-90
317
13.22
35.58
60-90
94
3.95
10.63
90-180
0
.00
.00
0-180
891
37.14
100.00
** Efficiency = 37.1% **
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .44 .44 .44 .44 .43 .43 .43 .43 .41 .41 .41 .40 .40 .40 .38 .38 .38 .37
1 .41 .40 .39 .37 .40 .39 .38 .37 .37 .37 .36 .36 .35 .35 .35 .34 .34 .33
2 .39 .36 .34 .33 .38 .36 .34 .32 .34 .33 .32 .33 .32 .31 .32 .31 .30 .30
3 .36 .33 .31 .29 .35 .32 .30 .29 .31 .30 .28 .31 .29 .28 .30 .28 .27 .27
4 .34 .30 .28 .26 .33 .30 .28 .26 .29 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .32 .28 .25 .23 .31 .27 .25 .23 .27 .24 .23 .26 .24 .23 .25 .24 .22 .22
6 .30 .26 .23 .21 .29 .25 .23 .21 .25 .22 .21 .24 .22 .20 .23 .22 .20 .20
7 .27 .23 .21 .19 .27 .23 .20 .19 .22 .20 .18 .22 .20 .18 .22 .20 .18 .18
8 .26 .21 .19 .17 .25 .21 .19 .17 .21 .18 .17 .20 .18 .17 .20 .18 .16 .16
9 .24 .20 .17 .15 .23 .19 .17 .15 .19 .17 .15 .19 .16 .15 .18 .16 .15 .14
10 .22 .18 .15 .14 .22 .18 .15 .13 .17 .15 .13 .17 .15 .13 .17 .15 .13 .13
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 36.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Luminance Summary - CD. / SQ. M.
Angle
Mean CD/SQ M
45
13825
55
4359
65
4460
75
5694
85
13872
Calculite 6" Recessed Vetro Downlight, Cat.# 8021CL/D6A01
32W G.E. Biax T/E Triple Tube (Lower Position).
Lumen Rating = 2200 Lms. Universal Ballast #C2642UNVBES
Candlepower Summary
Angle Mean CP LMS.
Angle Mean CP LMS.
0
459
90
20
5
448
44
95
17
15
10
489
100
3
15
526
146
105
2
2
20
524
110
2
25
487
223
115
2
2
30
426
120
2
35
356
222
125
2
2
40
274
130
2
45
178
138
135
2
1
50
85
140
2
55
45
48
145
2
1
60
39
150
2
65
34
34
155
2
1
70
31
160
2
75
27
29
165
2
1
80
24
170
2
85
22
24
175
2
0
90
20
180
2
Zonal Lumens and Percentages
Zone
Lumens
% Lamp
%Luminaire
0-30
413
18.77
44.29
0-40
634
28.84
68.05
0-60
820
37.32
88.03
0-90
907
41.26
97.35
40-90
273
12.42
29.30
60-90
86
3.95
9.31
90-180
24
1.12
2.65
0-180
932
42.39
100.00
** Efficiency = 42.4% **
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .50 .50 .50 .50 .49 .49 .49 .49 .46 .46 .46 .44 .44 .44 .42 .42 .42 .41
1 .47 .46 .44 .43 .46 .45 .43 .42 .42 .42 .41 .41 .40 .39 .39 .38 .38 .37
2 .44 .42 .40 .38 .43 .41 .39 .37 .39 .38 .36 .38 .36 .35 .36 .35 .34 .34
3 .41 .38 .36 .34 .40 .37 .35 .33 .36 .34 .33 .35 .33 .32 .34 .33 .31 .31
4 .39 .35 .33 .30 .38 .35 .32 .30 .34 .31 .30 .33 .31 .29 .32 .30 .29 .28
5 .37 .33 .30 .28 .36 .32 .29 .27 .31 .29 .27 .30 .28 .27 .29 .28 .26 .26
6 .35 .30 .27 .25 .34 .30 .27 .25 .29 .26 .25 .28 .26 .24 .27 .26 .24 .23
7 .32 .28 .25 .23 .32 .27 .25 .23 .27 .24 .22 .26 .24 .22 .25 .23 .22 .21
8 .30 .26 .23 .21 .30 .25 .23 .21 .25 .22 .20 .24 .22 .20 .24 .22 .20 .19
9 .28 .24 .21 .19 .28 .23 .21 .19 .23 .20 .19 .22 .20 .18 .22 .20 .18 .18
10 .27 .22 .19 .17 .26 .22 .19 .17 .21 .19 .17 .21 .18 .17 .20 .18 .17 .16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Certified test report# 3494FR
Computed by LSI program **TEST-LITE**
SC = 1.0
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
8021CL-D6AO1
250
500
0°
30°
60°
90°
125
375