background image

Job Information 

Type:

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt $

Lighting Systems

 CD7-5

1BHFPG

2

-PXQSPGJMF%JSFDU-FOT-JHIU51FS'PPU4FDUJPO

90˚

85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

800

1200

400

1800

1600

0

Performance and Quick Calculator

REPORT NO: 

-3-"

LAMPS: 

85

LUMENS: 

EFFICIENCY: 

CANDLEPOWER CURVE

CANDLEPOWER

;0/&

%&(

 

  

 

  

 

  

 

  

 

ZONAL LUMEN SUMMARY

 

;0/& -6.&/4

#"3&-".1

 

-6.*/"*3&

 

 

COEFFICIENTS OF UTILIZATION

&''&$5*7&$&*-*/($"7*5:3&'-&$5"/$&

70

8"--3&'-&$5"/$&

30 10

30 10

30 10

300.

$"

7*5:

3"

5*0

0

        

1

        

2

        

3

 

37

 

36 36

36

 

33 37

32 32

32

32 30

32

 

31

6

32

27 32

27 27

26

7

30 27

 

26

 

26

27

22 27

22 22

22

22 20

22 20 20 22 20

10 22

17 22

17 17

17

'-003$"7*5:3&'-&$5"/$&

94-1/2” (240.03c

m

)

49” (124.46c

m

)

94-1/2” (240.03c

m

)

20’ 5” (622.30c

m

)

8-Foot Fixture

4-Foot Fixture

8-Foot Fixture

45-1/2” (115.57c

m

)

49” (124.46c

m

)

94-1/2” (240.03c

m

)

98” (248.926c

m

)

37” (93.98c

m

)

6” (15.24c

m

)

4-Foot Cable and Ste

m

8-Foot Cable and Ste

m

Wall

49” (124.46c

m

)

Mounting Details

3-1/4” (8.26c

m

)

9” (22.86c

m

)

Ste

m

24”

(60.96c

m

)

3-1/4” (8.26c

m

)

9” (22.86c

m

)

Cable

24”

(60.96c

m

)

3-5/8”(9.21c

m

)

4-1/2”

(15.43c

m

)

Surface

9” (22.86c

m

)

3” (7.62c

m

)

12” (30.48c

m

)

Wall

Sample Run

20

10

20              30                40             50               60              70               80               90

40

60

80

100

120

ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR

INITIAL FOOTCANDLES

AREA PER FIXTURE IN SQUARE FEET

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

ABOVE DATA FOR 1LT-40 W 49” UNITS. FOR 2LT 49” UNITS FC X 17

3200 LUMENS PER LAMP

RCR  =  1  (R

m

. Width  =  10xMtg. Ht. above work plane)

RCR  =  5  (R

m

. Width  =  2xMtg. Ht. above work plane)

RCR  =  10  (R

m

. Width  =  Mtg. Ht. above work plane)

SPACING RATIOS: PARALLEL  =  1.2 / PERPENDICULAR  =  1.7

3            4              5                 6                         7                          8                            9

Fixture Lengths & Mounting Locations

Reviews: