background image

WALL

WASHER

INSIDE CORNER 

WALLWASHER

DOUBLE 

WALLWASHER

W

ALL

W

ALL

WALL

W

ALL

W

ALL

6'

6'

3'

2'

14 f.c.
10 f.c.

6'

Coefficients of Utilization

%

effective ceiling cavity reflectance

80

50

30

ROOM CA

VITY RA

TIO

20% FLOOR CAVITY REFLECTANCE

50 30

10

50

30

10

50

30

10

.76 .75 .73

.73 .72 .71

.70 .69

.69

.72 .69 .68

.69 .68 .67

.67 .67

.66

.67 .65 .63

.66 .64 .62

.65 .63

.61

.65 .61 .58

.63 .60 .58

.61 .59

.57

.60 .56 .54

.59 .56 .54

.58 .55

.53

.56 .53 .50

.55 .52 .50

.54 .52

.50

.52 .49 .47

.52 .48 .47

.51 .48

.47

.50 .47 .44

.49 .46 .44

.48 .46

.44

.47 .43 .40

.46 .43 .40

.46 .42

.40

.44 .40 .37

.43 .40 .37

.43 .39

.37

1

2

3

4

5

6

7

8

9

10

% CEILING REFLECTANCE

Conversion Factors:
100W A-19; (Clear): C.U. X 1.O. 100W and 150W A21  (Gold): C.U. X 0.9.

UNITS 2 FEET
FROM WALL

1

34

32

34

26

22

26

26

12

26

2

48

48

48

36

30

36

34

18

34

3

48

52

48

34

38

34

30

22

30

4

39

44

39

29

32

29

21

22

21

5

36

38

36

28

24

28

20

22

20

6

29

32

29

23

22

23

17

18

17

7

24

26

24

20

20

20

17

14

17

8

23

24

23

17

20

17

17

14

17

9

20

22

20

16

18

16

16

12

16

UNITS 3 FEET
FROM WALL

1

12

14

12

12

10

12

8

7

8

8

6

8

2

19

22

19

17

14

17

13

10

13

13

8

13

3

22

24

22

18

16

18

14

12

14

14

10

14

4

22

26

22

20

16

20

16

14

16

14

10

14

5

26

26

26

20

20

20

14

14

14

14

14

12

6

24

22

24

18

18

18

14

12

14

12

14

10

7

20

22

20

16

16

16

12

12

12

10

12

9

8

19

20

19

15

14

15

11

10

11

9

10

9

9

19

20

19

15

14

15

11

10

11

9

10

9

Footcandle values are averaged and rounded off and are based on a minimum of five units.
Conversion factors: 150W A21 units with gold cone, FC x 0.90.  100W units: clear cone, FC x 0.60; gold cone, FC x 0.55.

DIST

ANCE FROM CEILING (FT

.)

DIST

ANCE FROM CEILING (FT

.)

2'

3'

4'

3'

4'

5'

6'

Footcandles on wall from multiple units — clear cone, 150W A21

Clear cone, 100W A19

EXAMPLE: With multiple
clear cone units, using
150W A21 lamps, located
3’ from wall and 6' on cen-
ter, (matching downlights
7054 downlights 6’ on cen-
ter), the illumination on the
wall 3' down from the ceil-
ing is 14 f.c. beneath fix-
tures and 10 f.c. between
fixtures.

WALL WASH SIDE

DOWNLIGHT SIDE

For even wall washing use a maximum
of 2 to 1 spacing (distance between
f distance to wall).

DOWNLIGHT SPACING RATIO = 1.3

Candlepower Distribution

Calculite

®

Incandescent Open Wall Washer

R7029

Page 2 of 2

6" Aperture A19 / A21

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902

Job Information