background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0909

Job Information 

Type:

Calculite

®

 HID Surface Cylinder 

C6CS-C6T6VM

Page 2 of 2 

 6" Aperture, T6, Ceramic Metal Halide, Medium Beam

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL 

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR
  0 

.77  .77  .77  .77 

.75  .75 

.72  .72 

.69  .69 

.64

  1 

.74  .72  .71  .69 

.71  .68 

.68  .66 

.66  .64 

.61

  2 

.71  .68  .66  .64 

.67  .63 

.65  .62 

.63  .61 

.58

  3 

.68  .64  .61  .59 

.63  .59 

.62  .58 

.60  .57 

.55

  4 

.65  .61  .58  .55 

.60  .55 

.59  .54 

.57  .54 

.52

  5 

.62  .57  .54  .52 

.57  .51 

.56  .51 

.55  .50 

.49

  6 

.59  .54  .51  .49 

.54  .48 

.53  .48 

.52  .48 

.47

  7 

.56  .51  .48  .45 

.51  .45 

.50  .45 

.49  .45 

.44

  8 

.54  .48  .45  .42 

.48  .42 

.47  .42 

.47  .42 

.41

  9 

.51  .46  .42  .40 

.45  .40 

.45  .39 

.44  .39 

.38

  10  .49  .43  .39  .37 

.43  .37 

.42  .37 

.42  .37 

.36

 

LUMINAIRE INPUT WATTS =  

44

 ANGLE  MEAN CP  LUMENS

 

2382 

 

2347 

223

 

10 

2265 

 

15 

2086 

581

 

20 

1766 

 

25 

1385 

648

 

30 

1062 

 

35 

836 

518

 

40 

566 

 

45 

248 

209

 

50 

20 

 

55 

6

 

60 

 

65 

0

 

70 

 

75 

0

 

80 

 

85 

0

 

90 

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

1452 

42.71 

66.44

  0-40 

1970 

57.94 

90.14

  0-60 

2185 

64.28 

99.99

  0-90 

2185 

64.28 

100

  40-90 

215 

6.34 

9.86

  60-90 

0.01

  90-180 

0

  0-180 

2185 

64.28 

100 

39W T6 

PHILIPS CERAMIC MH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.                          

        ANGLE       MEAN CD/SQ M        

 

45 

21039

 

55 

301

 

65 

5

 

75 

19

 

85 

0

**  EFFICIENCY = 64.3%  ** 

CERTIFIED TEST REPORT NO. 2337FR, DATE: OCT 24, 2003

SC = 0.9 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL 

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR 
  0 

.76  .76  .76  .76 

.74  .74 

.70  .70 

.67  .67 

.63

  1 

.72  .71  .69  .68 

.70  .67 

.67  .65 

.65  .63 

.60

  2 

.69  .67  .65  .62 

.66  .62 

.63  .60 

.62  .59 

.57

  3 

.66  .63  .60  .58 

.62  .57 

.60  .57 

.59  .56 

.54

  4 

.64  .59  .56  .54 

.59  .54 

.57  .53 

.56  .52 

.51

  5 

.61  .56  .53  .50 

.55  .50 

.54  .50 

.53  .49 

.48

  6 

.58  .53  .50  .47 

.52  .47 

.51  .47 

.51  .46 

.45

  7 

.55  .50  .46  .44 

.49  .44 

.49  .44 

.48  .43 

.42

  8 

.53  .47  .43  .41 

.46  .41 

.46  .41 

.45  .41 

.40

  9 

.50  .44  .41  .38 

.44  .38 

.43  .38 

.43  .38 

.37

  10  .47  .41  .38  .36 

.41  .36 

.41  .35 

.40  .35 

.34

 

LUMINAIRE INPUT WATTS = 78

 ANGLE  MEAN CP 

LUMENS

 

4188 

 

4141 

394

 

10 

4047 

 

15 

3813 

1062

 

20 

3312 

 

25 

2664 

1244

 

30 

2115 

 

35 

1667 

1031

 

40 

1114 

 

45 

479 

408

 

50 

32 

 

55 

8

 

60 

 

65 

0

 

70 

 

75 

0

 

80 

 

85 

 

90 

70W T6 

PHILIPS CERAMIC MH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.                          

        ANGLE       MEAN CD/SQ M        

 

45 

40627

 

55 

293

 

65 

0

 

75 

0

 

85 

0

**  EFFICIENCY = 62.8%  ** 

CERTIFIED TEST REPORT NO. 2335FR, DATE: OCT 14, 2003

SC = 0.9 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

2700 

40.92 

65.12

  0-40 

3731 

56.53 

89.97

  0-60 

4147 

62.84 

100

  0-90 

4147 

62.84 

100

  40-90 

416 

6.3 

10.03

  60-90 

0

  90-180 

0

  0-180 

4147 

62.84 

100

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

1,250

30°

60°

30°

60°

625

1,875

2,500

2,000

1,000

3,000

4,000

Reviews: