background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • C1009

Job Information 

Type:

Calculite

®

 HID Downlight

  C4T4VW

Page 2 of 4 

4½" Aperture, 2pc Vertical, T4 Wide Beam

 ANGLE   MEAN CP   LUMENS

 

1162 

 

1128 

107

  10 

1055 

  15 

961 

270

  20 

832 

  25 

691 

326

  30 

600 

  35 

512 

307

  40 

331 

  45 

124 

115

  50 

11 

  55 

4

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

 

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

702 

41.33 

62.26

  0-40 

1009 

59.4 

89.5

  0-60 

1128 

66.36 

99.98

  0-90 

1128 

66.37 

100

  40-90 

118 

6.97 

10.5

  60-90 

0.02 

0.02

 90-180 

0

  0-180 

1128 

66.37 

100

20W T4 

GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat 20W Electronic Ballast, CL Finish Trim

 500 

 1000 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45 

17204 

 

 55 

 370 

 

65  

13

 

75 

0

 

85 

 0 

**EFFICIENCY = 66.4%** 

CERTIFIED TEST REPORT NO. 2318FR, DATE: SEP 28, 2003 

SC = .9 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

 ANGLE   MEAN CP   LUMENS

 

1725 

 

1679 

160

  10 

1602 

  15 

1542 

436

  20 

1464 

  25 

1371 

641

  30 

1332 

  35 

1104 

659

  40 

655 

  45 

242 

225

  50 

24 

  55 

8

  60 

  65 

1

  70 

  75 

0

  80 

  85 

0

  90 

39W T4 

Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat 39W Electronic Ballast, CL Finish Trim

 750 

 1500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45  

33540 

 

 55  

928 

 

65  

78 

 

75  

 

85  

**EFFICIENCY = 64.5%** 

CERTIFIED TEST REPORT NO. 2317FR, DATE: SEP 27, 2003

SC = 1.1 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

1236 

37.46 

58.06

  0-40 

1895 

57.42 

88.99

  0-60 

2128 

64.51 

99.97

  0-90 

2129 

64.53 

100

  40-90 

234 

7.1 

11.01

  60-90 

0.02 

0.03

 90-180 

0

  0-180 

2129 

64.53 

100

 ANGLE   MEAN CP   LUMENS

 

3202 

 

3121 

296

  10 

2971 

  15 

2858 

810

  20 

2741 

  25 

2618 

1208

  30 

2467 

  35 

2000 

1206

  40 

1210 

  45 

445 

414

  50 

39 

  55 

11

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

70W T4 

Philips CMH Lamp, Lumen Rating = 6400 LMS, Aromat 70W Electronic Ballast, CL Finish Trim

 1500 

 3000 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45  

61531 

 

 55  

806 

 

65  

 

75  

 

85  

0

**EFFICIENCY = 61.6%** 

CERTIFIED TEST REPORT NO. 2316FR, DATE: SEP 27, 2003

SC = 1.1 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

   0-30 

2314 

36.16 

58.67

  0-40 

3520 

55 

89.23

  0-60 

3944 

61.64 

100

  0-90 

3944 

61.64 

100

  40-90 

424 

6.64 

10.77

  60-90 

0

 90-180 

0

  0-180 

3944 

61.64 

100

250

500

750

1000

375

750

1125

1500

750

1500

2250

3000

30°

60°

30°

60°

30°

60°

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.79

.79

.79

.79

.77

.77

.74

.74

.71

.71

.67

1

.76

.74

.73

.72

.73

.70

.70 .68 .68 .66 .63

2

.73

.70 .68 .66 .69 .65

.67 .63 .65 .62 .60

3 .69 .66 .63 .60 .65 .60 .63 .59 .62 .58 .56
4 .66 .62 .59 .56

.61 .56 .60 .55 .59 .55 .53

5 .63 .58 .55

.52 .58

.52 .56

.52 .55

.51 .50

6 .60 .55

.51

.49 .55

.49 .54

.48 .53

.48

.47

7

.57

.52

.48

.46

.51

.45 .50

.45 .50

.45 .44

8 .55

.48

.45

.42

.48

.42

.47

.42

.47

.42

.41

9

.52

.46

.42 .39

.45 .39 .44 .39 .44 .39 .38

10

.49 .43 .39 .36

.42 .36

.42 .36

.41 .36 .35

LUMINAIRE INPUT WATTS = 23

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.77

.77

.77

.77

.75

.75

.72

.72 .69 .69 .65

1

.74

.72

.71 .69

.71 .68 .68 .66 .66 .64

.61

2

.70 .68 .65 .63 .66 .62 .64

.61 .63 .60 .58

3

.67 .63 .60 .58 .62 .58

.61

.57 .59 .56 .54

4 .64 .59 .56 .54 .59 .53

.57 .53 .56

.52

.51

5

.61 .56

.52

.49 .55

.49 .54

.49 .53

.48

.47

6 .58

.52

.49

.46

.52

.46

.51

.46 .50

.45 .44

7 .55

.49

.45 .43

.48

.42

.48

.42

.47

.42

.41

8

.52

.46

.42 .39

.45 .39 .44 .39 .44 .39 .38

9

.49

.42 .39 .36

.42 .36

.41 .36

.41 .36 .35

10

.46

.40 .36 .33 .39 .33 .39 .33 .38 .33 .32

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.74

.74

.74

.74

.72

.72 .69 .69 .66 .66 .62

1

.71 .69 .68 .66 .68 .65 .65 .63 .63

.61 .58

2

.67 .65 .63 .60 .64 .60 .62 .59 .60

.57 .55

3 .64

.61 .58 .56 .60 .55 .58 .54

.57 .53

.52

4

.61

.57 .54

.51 .56

.51 .55

.51 .54 .50

.49

5 .58 .53 .50

.47 .53

.47

.52

.47

.51

.46

.45

6 .55 .50

.47 .44 .50 .44

.49 .44

.48 .43

.42

7

.52

.47 .43

.41

.47

.41

.46

.41

.45

.40 .39

8 .50 .44

.40 .38 .43 .38 .43 .37

.42 .37 .36

9

.47

.41 .37 .35

.40 .35

.40 .34 .39 .34 .33

10 .44 .38 .34 .32 .38 .32 .37 .32 .37 .32

.31

LUMINAIRE INPUT WATTS = 78

Summary of Contents for Calculite C4T4VW

Page 1: ...joists without accessories 8 Trim Retention Springs Rust resistant springs secure reflector housing for quick tool less installation 9 Ballast Socket Housing Cover Assembly Snaps onto junction box without tools for inspection and ballast replacement accessible from below 10 Junction Box 0 048 18 ga galvanized steel UL listed for 8 No 12 AWG 90 C through branch circuit conductors Allows inspection ...

Page 2: ...MARY CD SQ M ANGLE MEAN CD SQ M 45 61531 55 806 65 0 75 0 85 0 EFFICIENCY 61 6 CERTIFIED TEST REPORT NO 2316FR DATE SEP 27 2003 SC 1 1 COMPUTED BY LSI PROGRAM TEST LITE CANDLEPOWER DISTRIBUTION ZONAL LUMENS AND PERCENTAGES ZONE LUMENS LAMP LUMINAIRE 0 30 2314 36 16 58 67 0 40 3520 55 89 23 0 60 3944 61 64 100 0 90 3944 61 64 100 40 90 424 6 64 10 77 60 90 0 0 0 90 180 0 0 0 0 180 3944 61 64 100 25...

Page 3: ... 27273 55 491 65 0 75 0 85 0 EFFICIENCY 58 7 CERTIFIED TEST REPORT NO 3911FR SC 1 1 COMPUTED BY LSI PROGRAM TEST LITE CANDLEPOWER DISTRIBUTION ZONAL LUMENS AND PERCENTAGES ZONE LUMENS LAMP LUMINAIRE 0 30 1025 34 18 58 25 0 40 1568 52 29 89 13 0 60 1760 58 67 99 99 0 90 1760 58 67 100 40 90 191 6 38 10 87 60 90 0 0 0 01 90 180 0 0 0 0 180 1760 58 67 100 200 400 600 350 700 1050 1400 30 60 30 60 Coe...

Page 4: ...65 0 75 0 85 0 EFFICIENCY 62 6 CERTIFIED TEST REPORT NO 3914FR SC 0 9 COMPUTED BY LSI PROGRAM TEST LITE CANDLEPOWER DISTRIBUTION ZONAL LUMENS AND PERCENTAGES ZONE LUMENS LAMP LUMINAIRE 0 30 1302 38 3 61 2 0 40 1897 55 82 89 21 0 60 2127 62 57 99 99 0 90 2127 62 57 100 40 90 229 6 75 10 79 60 90 0 0 01 0 01 90 180 0 0 0 0 180 2127 62 57 100 225 450 675 900 500 1000 1500 2000 30 60 30 60 Coefficient...

Reviews: