Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • G0711
Calculite
®
Evolution
C4P20L
Page 2 of 2
4 1/2" Aperture PAR20 / PAR16 Incandescent Lensed Wall Washer Reflector Trim
Footcandle values are averaged and rounded off and are based on a minimum of five units.
75W PAR16 NFL
EXAMPLE: With multiple units located 2' from
wall and 2’ on center, the illumination on the
wall 3’ down from the ceiling is 12 f.c. beneath
and 11f.c. between fixtures.
Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.
2’
2’
3’
12 f.c.
11 f.c.
Footcandles on Wall From Multiple Units
Conversion Factors:
37W IR and 50W MR16 FL: F.C. x 0.6
37W IR and 35W MR16 FL: F.C. x 0.4
37W IR and 20W MR16 FL: F.C. x 0.2
2'
3'
1’
4
4
4
4
2
4
2’
10
9
10
7
5
7
3’
12
11
12
9
7
9
4’
13
12
13
9
7
9
5’
11
11
11
8
7
8
6’
9
9
9
6
6
6
7’
7
7
7
5
5
5
8’
6
6
6
4
4
4
9’
5
5
5
3
3
3
Units 2 Feet From Wall
Distance
From
Ceiling,
Ft.
3'
4'
1’
1
1
1
1
1
1
2’
3
3
3
3
2
3
3’
4
4
4
4
3
4
4’
5
5
5
4
3
4
5’
6
5
6
5
4
5
6’
6
5
6
5
4
5
7’
5
5
5
4
4
4
8’
5
5
5
4
4
4
9’
4
4
4
3
3
3
Units 3 Feet From Wall
Distance
From
Ceiling,
Ft.
50W PAR20 NFL
EXAMPLE: With multiple units located 2’ from
wall and 2’ on center, the illumination on the
wall 3’ down from the ceiling is 7 f.c. beneath
and 6 f.c. between fixtures.
Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.
2’
2’
3’
7 f.c.
6 f.c.
Footcandles on Wall From Multiple Units
Conversion Factors:
37W IR and 50W MR16 FL: F.C. x 0.6
37W IR and 35W MR16 FL: F.C. x 0.4
37W IR and 20W MR16 FL: F.C. x 0.2
2'
3'
1’
2
2
2
2
1
2
2’
5
5
5
4
3
4
3’
7
6
7
5
3
5
4’
7
7
7
5
4
5
5’
6
6
6
4
4
4
6’
5
5
5
3
3
3
7’
4
4
4
2
2
2
8’
3
3
3
2
2
2
9’
3
3
3
2
2
2
Units 2 Feet From Wall
Distance
From
Ceiling,
Ft.
3'
4'
1’
1
1
1
1
1
1
2’
2
1
2
1
1
1
3’
2
2
2
2
1
2
4’
3
2
3
2
2
2
5’
3
3
3
3
2
3
6’
3
3
3
3
2
3
7’
3
3
3
2
2
2
8’
3
3
3
2
2
2
9’
2
2
2
2
2
2
Units 3 Feet From Wall
5˚
5˚
25˚
25˚
45˚
45˚
Candlepower Curve
Report 0851FR
Efficiency = 37.3%
Down
Wall
5˚
5˚
25˚
25˚
45˚
45˚
Report 0852FR
Efficiency = 42.0%
Footcandle values are averaged and rounded off and are based on a minimum of five units.
Down
Wall
Distance
From
Ceiling,
Ft.
Candlepower Curve