Calculite

®

 Evolution

 C4P20L

Page 2 of 2 

4 1/2" Aperture PAR20 / PAR16 Incandescent Lensed Wall Washer Reflector Trim

Footcandle values are averaged and rounded off and are based on a minimum of five units.

75W PAR16 NFL

EXAMPLE: With multiple units located 2' from
wall and 2’ on center, the illumination on the
wall 3’ down from the ceiling is 12 f.c. beneath 
and 11f.c. between fixtures.

Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.

2’

2’

3’

12 f.c.

11 f.c.

Footcandles on Wall From Multiple Units

Conversion Factors:
37W IR and 50W MR16 FL: F.C. x 0.6
37W IR and 35W MR16 FL: F.C. x 0.4
37W IR and 20W MR16 FL: F.C. x 0.2

2'

3'

1’

4

4

4

4

2

4

2’

10

9

10

7

5

7

3’

12

11

12

9

7

9

4’

13

12

13

9

7

9

5’

11

11

11

8

7

8

6’

9

9

9

6

6

6

7’

7

7

7

5

5

5

8’

6

6

6

4

4

4

9’

5

5

5

3

3

3

Units 2 Feet From Wall

Distance 

From 

Ceiling, 

Ft.

3'

4'

1’

1

1

1

1

1

1

2’

3

3

3

3

2

3

3’

4

4

4

4

3

4

4’

5

5

5

4

3

4

5’

6

5

6

5

4

5

6’

6

5

6

5

4

5

7’

5

5

5

4

4

4

8’

5

5

5

4

4

4

9’

4

4

4

3

3

3

Units 3 Feet From Wall

Distance 

From 

Ceiling, 

Ft.

50W PAR20 NFL

EXAMPLE: With multiple units located 2’ from
wall and 2’ on center, the illumination on the
wall 3’ down from the ceiling is 7 f.c. beneath 
and 6 f.c. between fixtures. 

Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than

those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.

2’

2’

3’

7 f.c.

6 f.c.

Footcandles on Wall From Multiple Units 

Conversion Factors:
37W IR and 50W MR16 FL: F.C. x 0.6
37W IR and 35W MR16 FL: F.C. x 0.4
37W IR and 20W MR16 FL: F.C. x 0.2

2'

3'

1’

2

2

2

2

1

2

2’

5

5

5

4

3

4

3’

7

 

6

 

7

5

3

5

4’

7

 

 7

5

4

5

5’

6

 

6

 

6

4

4

4

6’

5

5

5

3

3

3

7’

4

4

4

2

2

2

8’

3

3

3

2

2

2

9’

3

3

3

2

2

2

Units 2 Feet From Wall

Distance 

From 

Ceiling, 

Ft.

3'

4'

1’

1

1

1

1

1

1

2’

2

1

2

1

1

1

3’

2

2

2

2

1

2

4’

3

2

3

2

2

2

5’

3

3

3

3

2

3

6’

3

3

3

3

2

3

7’

3

3

3

2

2

2

8’

3

3

2

2

2

9’

2

2

2

2

2

2

Units 3 Feet From Wall

25˚

25˚

45˚

45˚

Candlepower Curve

Report 0851FR
Efficiency = 37.3%

Down 

Wall

25˚

25˚

45˚

45˚

Report 0852FR
Efficiency = 42.0%

Footcandle values are averaged and rounded off and are based on a minimum of five units. 