background image

Lighting Systems

 

Baselyte-BSL22

Page 5 of 8   

2 Light T8 Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.)

Supension Length

Non-Power Mount

1-Power Mount

2-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13

  4 Conductor

BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14

  7 Conductor

BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17

2-Power Mount

  3 Conductor

BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23

Non-Power Mount

BSLM1102N

BSLM1104N

BSLM1108N

BSLM1112N

•   Meets UBC, OSHPD and DSA seismic requirements

•   Canopy: Diameter of 5 

/4

“x 

3/4

” (power)

•   Cable: 7x7 stranded aircraft cable

•   Mountable on 0º - 5º sloped ceiling

•   Optional Chicago Plenum approved version available (A4)

•   J-Box: 4” octogonal box (supplied by others)

•   Fully vertically adjustable at fixture

•  Max. 0 amps
•  Max. 300V

•  Max. 0 amps in a  circuit application
•  Max. 5 amps per circuit in a 2 circuit application
•  Max. 300V 
•  Good for 2 circuit feeds or a  circuit feed with  
 

a battery pack hot lead

•  20V or 277V applications

•  Max. 0 amps in a  circuit application 
•  Max. 5 amps per circuit in a multi-circuit    
 

application

•  Good for 3 circuit feeds or 2 circuit feeds with a  
 

battery pack hot lead

•  20V or 277V applications
  

3 Conductor

4 Conductor

7 Conductor

Cord Types

Summary of Contents for Baselyte-BSL22

Page 1: ...wder coat finish 3 Lamping two T8 lamps 4 Configuration 4 8 and 12 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish...

Page 2: ...0 0 0 0 75 0 0 0 0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WA...

Page 3: ...d aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stra...

Page 4: ...h 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM311...

Page 5: ...BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 str...

Page 6: ...B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by install...

Page 7: ...gency Circuit Night Light EC NL One 4 section in two circuit fixture left right switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends A...

Page 8: ...witching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit fixtu...

Reviews: