background image

Lighting Systems

 

Baselyte-BSL22

Page 2 of 8   

2 Light T8 Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Performance

Candlepower Curve

Candlepower Summary

Coefficients of Utilization

Module Lengths & Mounting Distances

Joiner

BSLESW

 = suspended standard white

Dust Cover

End Set

BSLJS

 = suspended joiner

BSLDCS 

= 4’ suspended dust cover 

System Components & Accessories

Run Configuration 

Run

Length

 

4’ 

Module

8’

Module

2’ 

Module

Joiner

End Set

Mount

Power 

Mount*

4’ run

8’ run

2’ run

6’ run

2

2

20’ run

2

24’ run

2

2

28’ run

2

2

3

32’ run

2

3

Report No:

 20584

Lamps: 

F32T8

Lumens per Lamp: 

2950

Efficiency:

 87.7.%

Up:

 00.0%  

Down:

 0.0%

Zonal Lumen Summary

ZONE 

LUMENS    %BARE LAMP       %LUMINAIRE

-ODULE,ENGTH

-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

@

@

@

CANDLEPOWER SUMMARY

ZONE

CANDLEPOWER

DEG.

0

22.5

45

67.5

90

180

1339

1339

1339

1339

1339

175

1332

1335

1339

1342

1343

165

1285

1297

1323

1342

1350

155

1196

1222

1287

1337

1358

145

1069

1115

1233

1323

1358

135

906

985

1164

1293

1339

125

713

839

1081

1209

1253

115

495

695

931

985

1007

105

266

490

600

558

565

95

68

114

166

131

136

90

2

2

10

4

6

85

0

0

0

0

0

75

0

0

0

0

0

65

0

0

0

0

0

55

0

0

0

0

0

45

0

0

0

0

0

35

0

0

0

0

0

25

0

0

0

0

0

15

0

0

0

0

0

5

0

0

0

0

0

0

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

83

83

83

71

71

71

48

48

48

1

72

69

66

62

59

57

42

41

39

2

63

58

54

54

50

46

37

34

32

3

55

49

45

47

42

39

32

29

27

4

48

42

37

41

36

32

28

25

23

5

43

36

31

37

31

27

25

22

19

6

38

32

27

33

27

23

22

19

16

7

34

28

23

29

24

20

20

17

14

8

31

24

20

26

21

17

18

15

12

9

28

22

17

24

19

15

16

13

11

10 25

19

15

21

17

13

15

12

9

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

5178

5178

0

0
100.0
100.0

0
87.8
87.8

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

83

83

83

71

71

71

48

48

48

1

72

69

66

62

59

57

42

41

39

2

63

58

54

54

50

46

37

34

32

3

55

49

45

47

42

39

32

29

27

4

48

42

37

41

36

32

28

25

23

5

43

36

31

37

31

27

25

22

19

6

38

32

27

33

27

23

22

19

16

7

34

28

23

29

24

20

20

17

14

8

31

24

20

26

21

17

18

15

12

9

28

22

17

24

19

15

16

13

11

10 25

19

15

21

17

13

15

12

9

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

5178

5178

0

0
100.0
100.0

0
87.8
87.8

Note

: Shaded area indicates locations of emergency sections (emergency wiring  

controls all lamps or optional battery pack controls one or two lamps).

*Note

: Additional power mounts may be required for some runs with T5 HO 

lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.

Summary of Contents for Baselyte-BSL22

Page 1: ...wder coat finish 3 Lamping two T8 lamps 4 Configuration 4 8 and 12 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish...

Page 2: ...0 0 0 0 75 0 0 0 0 0 65 0 0 0 0 0 55 0 0 0 0 0 45 0 0 0 0 0 35 0 0 0 0 0 25 0 0 0 0 0 15 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WA...

Page 3: ...d aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stra...

Page 4: ...h 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM311...

Page 5: ...BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 str...

Page 6: ...B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by install...

Page 7: ...gency Circuit Night Light EC NL One 4 section in two circuit fixture left right switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends A...

Page 8: ...witching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit fixtu...

Reviews: