background image

Restoring Factory Defaults

CAUTION:

When setting modules back to Factory

Defaults, you will be erasing ALL of the programming
that has been performed. Make sure you won’t be 
loosing anything important before proceeding.

1.

Press and hold the Laser   

button and aim laser 

beam at an individual modules receiver to select it 
and place it in program mode. (When using multiple 
modules, select them in the same manner if they 
need to be programmed identically to the first
module.) The module’s LED(s) will blink at a 1/2 sec-
ond rate when in program mode. The LRC’s LED will 
also blink (every 1 second) to indicate the transmitter 
will be transmitting program IR commands when but
tons are depressed. (After 60 seconds of inactivity, 
the module(s) will exit the program mode without
saving.)

2.

Press and hold the Begin  

b

button for greater than 

3 seconds (the module’s LED(s) will blink rapidly and 
then after 3 seconds stay on). Release the Begin   

b

button. The module’s LED(s) will blink at a 1/4 second 
rate. (After 60 seconds of inactivity, the module(s) will 
exit the program mode without saving.)

3.

Press and hold the Laser       button and aim laser 
beam at the module(s) you are programming. This will
reinitialize the module to its factory defaults.

NOTE:

Any other sequence will prevent the Factory

Defaults from being set.

9. Troubleshooting

When I point the LRC at the TM and try to raise or lower
the light level of all of the modules, nothing happens.

• Check the LED on the LRC. If it is blinking, this means 

you’re in select/program mode. In order to raise or 
lower modules with a TM in this mode, you must 
individually select the modules you want to change or
if you want all modules to raise or lower at the same 
time, you must exit this mode first by pressing the
end  

e

button.

When dimming, the module will continue to dim even
after I’ve stopped pressing the remote buttons.

• Because of the delay in receiving IR commands, the 

desired light level may have been missed. Therefore 
release the up 

or down        button’s prior to the 

desired light level.

• Make sure there is a good ground throughout,

starting at the luminaire ground and ending with the 
earth ground.

Factory Defaults

Factory Defaults for the DM

Address:

C1 (House "C", Unit "1")

IR: Disabled (When not in Program Mode)

Present Scene:

ON Scene

Present Level:

100%

OFF:

Level 0% - Fade 3 Sec

ON Scene:

Level 100% - Fade 3 Sec

A

Scene:

Level 86% - Fade 3 Sec

B

Scene:

Level 72% - Fade 3 Sec

C

Scene:

Level 58% - Fade 3 Sec

D

Scene:

Level 44% - Fade 3 Sec

E

Scene:

Level 30% - Fade 3 Sec

F

Scene:

Level 16% - Fade 3 Sec

G

Scene:

Level 13% - Fade 3 Sec

H

Scene:

Level 10% - Fade 3 Sec

I

Scene:

Level 7% - Fade 3 Sec

J

Scene:

Level 5% - Fade 3 Sec

K

Scene:

Level 3% - Fade 3 Sec

Scene:

Level 1% (Night Light) - Fade 3 Sec

Factory Defaults for the NDM

Address:

C1 (House "C", Unit "1")

IR:

Disabled (When not in Program Mode)

Present Scene:

ON Scene

Present Level:

100%

OFF:

Level 0% - Fade 0 Sec

ON Scene:

Level 100% - Fade 0 Sec

A-L Scene:

Level 100% - Fade 0 Sec

Factory Defaults for the TM

Address:

C1 (House "C", Unit "1")

IR:

Enabled 

Present Scene:

ON Scene

Cycle ‘A’ Program:

Scenes A - B - C - D. All have

1.5 second fade rates and will

switch scenes every 3 seconds

Cycle ‘B’ Program:

Cleared

Cycle ‘C’ Program:

Cleared

Cycle ‘D’ Program:

Cleared

Cycle ‘E’ Program:

Cleared

Cycle ‘F’ Program:

Cleared

Verify:

Disabled

24

25

Scenes are only
available when
using a Lightolier
Controls Compose
8 Button Wall
Master. Consult
factory for more
information and
programming
instructions. 

Summary of Contents for Atom Lytespan CAM250VA

Page 1: ...Addressable Track Module System Installation Operations Manual For Use with Catalog Numbers CAM250VA CAM250ND CAMTM CAMWRC CAMLRC Lytespan Track Lighting...

Page 2: ...ack circuit ATOM is compatible with Lightolier Controls Compose System 2 Understanding the Components Addressable Track Dimming Module DM CAM250VA Individually addressable module that mounts anywhere...

Page 3: ...d run multiple lighting scenes set fade rates set cycle times and begin and end cycles The remote operates the Dimming Module Non Dim On Off Module and Track Master Module Addressable Track Non Dimmin...

Page 4: ...end cycles A TM must be used with the Wall Remote Control to run a cycle A TM is not needed to switch between scenes The Wall Remote Control can control up to 17 modules per circuit To control more t...

Page 5: ...e same IR program commands and their scene settings will be identical Learn When not in program mode press this button to make the Module s LED s blink so they can be easily located on the ceiling or...

Page 6: ...odule The module s LED s will blink at a 1 2 second rate when in program mode The LRC s LED will also blink every 1 second to indicate the transmitter will be transmitting program IR commands when but...

Page 7: ...ond to scene changes Testing a TM 1 Turn off power to track 2 Install modules into track with luminaire attached See Section 3 Installation of Modules to Lytespan Track Systems Install TM into track R...

Page 8: ...le sequence with fade rates and or time delays follow steps 6a 6b and 6c a To enter or change a Fade Rate press the fade f button for a 1 1 2 second fade or f and one of the TIME buttons 3 7 15 30 sec...

Page 9: ...ram Mode 1 Press and hold the Laser button and aim laser beam at an individual modules receiver to select it and place it in program mode When using multiple modules select them in the same manner if...

Page 10: ...exit and save the address settings The module s LED s will blink at a 1 2 second rate when in program mode The LRC s LED will also blink every 1 second to indicate the transmitter will be transmitting...

Page 11: ...lly start that same cycle over again from the beginning step when power returns Turning On Off DM NDM TM Using the LRC NOTE If using a TM and would like to communicate with all modules with it s same...

Page 12: ...ogram mode transmitting program IR commands when buttons are depressed After 60 seconds of inactivity the module s will exit the program mode without saving 2 Press a SCENE button to be programmed A B...

Page 13: ...ly select the modules you want to change or if you want all modules to raise or lower at the same time you must exit this mode first by pressing the end e button When dimming the module will continue...

Page 14: ...or use at any time Each group of saved settings is called a scene Each module has 6 programmable scenes A through F and On and Off scenes System A group of more than one DM and or NDM used with a TM a...

Page 15: ...se DO NOT THROW AWAY For technical sales assistance call 1 800 526 2731 Made in U S A Lightolier 2001 www lightolier com www lolcontrols com IS ATOM A Genlyte Company 631 Airport Road Fall River MA 02...