background image

6700MS22UNY

Decorative, Discus, Circline Fluorescent, 1 Lt. 22W

Page 3 of 3

Philips Lightolier

e: [email protected]

t:  (508) 679-8131

w: www.lightolier.com
6700MS22UNY  May 31, 2011
Specifications are subject to change without notice. 

© Koninklijke Philips Electronics N.V., 2011. All rights reserved.

Job Information 

Type:

3        4         5              6              7               8                   9                   10

10       20       30       40       50       60      70      80      90     100

  60

  50

  40

  30

  20

  10

AREA PER FIXTURE IN SQUARE FEET

Initial F

ootcandles

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Use quick calculator chart to determine the number and spacing

of luminaires for desired level of illumination.

ROOM SURFACE REFLECTANCES

80% Ceiling, 50% Walls, 20% Floor

1800 Lumens Per Lamp

RCR = 1 (60' x 60' x 8.5' room)

RCR = 5 (12' x 12' x 8.5' room)

RCR = 10 (6' x 6' x 8.5' room)

180

150

120

80

90

30

0

300

200

100

ACROSS

45

ALONG

Candlepower summary

Angle Mean CP  LMS

Angle Mean CP LMS

0

247

90

28

5

246

24

95

25

29

10

243

100

25

15

238

68

105

28

30

20

232

110

32

25

222

103

115

37

37

30

212

120

42

35

199

125

125

48

44

40

185

130

54

45

169

131

135

58

45

50

152

140

61

55

133

120

145

64

40

60

114

150

65

65

94

94

155

65

31

70

76

160

65

75

59

64

165

64

18

80

46

170

59

85

35

40

175

57

6

90

28

180

54

Zonal Lumens and Percentages

Zone Lumens %Lamp %Luminaire

0-30

193

10.76

18.58

0-40

318

17.69

30.57

0-60

568

31.59

54.57

0-90

765

42.52

73.45

40-90

446

24.83

42.89

60-90

196

10.93

18.89

90-180

276

15.37

26.55

0-180

1042

57.89

100.00

**Efficiency = 57.9%**

Coefficients Of Utilization  

% Effective Ceiling Cavity Reflectance - Effective Floor Cavity Reflectance = .20

RC

80

70

50

30

10

0

RW 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.57 .54 .52 .54 .52 .50 .49 .47 .45 .44 .42 .41 .39 .38 .37 .35

2

.49 .46 .42 .47 .43 .41 .42 .40 .37 .38 .36 .34 .34 .33 .31 .29

3

.43 .39 .35 .47 .41 .37 .38 .34 .32 .34 .31 .29 .31 .29 .27 .23

4

.39 .34 .30 .43 .37 .34 .32 .33 .30 .30 .27 .25 .27 .25 .23 .21

5

.34 .29 .25 .39 .32 .29 .28 30 26 .27 .24 .21 .24 .22 .20 .18

6

.30 .25 .22 .36 .29 .24 .24 .26 .23 .24 .21 .18 .22 .19 .17 .16

7

.27 .22 .19 .33 .26 .21 .22 .24 .20 .22 .18 .16 .20 .17 .15 .14

8

.24 .20 .16 .30 .23 .17 .19 .21 .18 .20 .16 .14 .18 .15 .13 .13

9

.22 .17 .14 .28 .21 .16 .17 .19 .16 .18 .14 .12 .16 .13 .11 .10

10 .20 .15 .12 .26 .19 .14 .15 .18 .14 .16 .13 .11 .15 .12 .10 .09

Room Ca

vity Ratio

Certified Test Report 

No: 1927FR

Computed by LSI Program

**TEST-LITE**

Date: June 25, 2002

Prepared for:

Lightolier

Fall River, MA

Lightolier Surface Utility Fluorescent, Discus with twist lock diffuser, 22W Circline Sylvania Lamp, 
Lumen Rating = 1800 LMS, Magnetek Ballast #C2642UNVSE, 120V

Tested according to IES procedures. 

Test distance exceeds five times the 

greatest luminous opening of luminaire.

8' 8"

9'

9'

8'

8 fc

9 fc

Spacing Ratio = 1.3

Corridor

6700MS22U

6.4 fc. average

0.35W/sf