LIGHTNIN
MIXERS AND AERATORS
®
REVISION
2001
DATE 3–16–83
REVISED 2–26–01
INST. NO. IT–1997
C
PAGE 4 OF 9
LIGHTNIN
MIXERS AND AERATORS
®
©
©
LIGHTNIN
LIGHTNIN
SECTION 4 – FLEX MOUNT REPLACEMENT
4.1 The flex mounts can be removed with a long bolt and two pieces of tubing as shown in Figure 4.
HEX HEAD CAP SCREW
PLAIN WASHER
TUBING
FLEX MOUNT (25)
HOUSING (36)
TUBING
PLAIN WASHER
HEX NUT
(MINIMUM 5 INCHES
LONG)
(7/8 INCH MAXIMUM
OUTSIDE DIAMETER)
(2 INCH MINIMUM
INSIDE DIAMETER)
OR PLATE
FIGURE 4 – FLEX MOUNT REMOVAL
4.2 Tighten the nut until the mount is free of the housing.
4.3 To install new mounts, use a long bolt and a piece of tubing as shown in Figure 5.
HEX HEAD CAP SCREW
PLAIN WASHER
TUBING
FLEX MOUNT (25)
HOUSING (36)
PLAIN WASHER
HEX NUT
(MINIMUM 4–1/2 INCHES
LONG)
(1–3/8 INCH MINIMUM
INSIDE DIAMETER)
FIGURE 5 – FLEX MOUNT INSTALLATION
4.4 Lubricate the mount with a natural rubber lubricant or liquid hand soap.
4.5 Tighten the nut until the mount is tight with the housing base.
4.6 Replace ALL mounts if one is replaced.
4.7 Tighten mounting hardware to 85 ft–lbs. Use double nuts to lock in position.
SECTION 5 – MIXER LUBRICATION
5.1 STANDARD GEAR LUBRICANT – The factory supplied NLGI EP0 grease is a high quality lubricant with a
lithium base, suitable for operation in ambient temperatures ranging b50
°
F and +200
°
F. Under
normal operating conditions, this lubricant need not be changed until the unit has been dismantled
for some reason.
5.2 Under adverse operating conditions, periodic changes of lubricant may be necessary. Adverse conditions are
defined as operating in very humid, dust laden or chemical atmospheres, or where wide variations in ambient
temperature occurs. Such adverse conditions can lead to deterioration of lubricant compounds and additives,
and it is recommended that the condition of the grease be checked within six months after start up. Reputable
lubricant suppliers can analyze the grease and recommend economical, safe change schedules.
5.3 Gear Lubricant Recommendations:
Use only a lubricant suitable for the temperature and operating conditions.
AMBIENT
TEMP.
RANGE
50
°
F to 200
°
F
NLGI #
EP 0
BASE
LITHIUM
MIN. OIL
VISCOSITY
SUS
750 @ 100
°
F
76 @ 210
°
F
200
°
F
MAX.
OPERATING
TEMP.