Set interval 

To set the interval, press "

Menu

" until "

Interval set

" appears on the display.  

Then use the Up/Down buttons to set the fog pause from 5 to 200 seconds.  
 

This setting is required if you want to use the 

timer mode

 

 

Setting the fog duration 

To set the duration, press "

Menu

" until the display shows "

Duration set

".  

Use the Up/Down buttons to set the fog duration from 1 to 200 seconds. 

 
This setting is required if you want to use the 

timer mode

 
 

Setting the Fog Level for Timer Mode 

To set the fog quantity for the timer mode, press "

Menu

" until the display shows "

Timer out

". 

Use the Up/Down buttons to set the fog quantity from 1 to 100%. 
 

This setting is required if you want to use the 

timer mode

 
 

Setting the Fog Level for Volume Mode 

To adjust the fog quantity, press "

Menu

" until the display shows "

Volume out

".  

Use the Up/Down buttons to adjust the fog volume from 1 to 100%. 
 

This setting is required if you want to use the option 

Volume (Continuous Mode)

 

 

Setting the fan speed 

To set the fan speed, press "

Menu

" until the display shows "

Fan Speed

".  

Use the Up/Down buttons to set the fan speed between 1 and 100%. 

 
 

Setting the DMX address 

To set the DMX address, press "

Menu

" until the display shows "

DMX ADD xxx

".  

Then use the Up/Down buttons to set the value from 001 to 512. 
 

 

Activating/deactivating the liquid sensor 

Press "

Menu

" until "

Fluid sensor

" appears in the display. 

Use the Up/Down buttons to activate or deactivate the fluid sensor (On/off). 

 
When the Fluid sensor is activated, the display shows "Ready to Fazer S".  

If the Fluid sensor is deactivated, the display shows "Ready to Faze". 
 

 

 

 

Summary of Contents for Vector Haze 1.7

Page 1: ... DANGER For babies and children Dispose of or store any packaging material properly Packaging material must be kept out of the reach of babies and children due to the risk of suffocation Ensure that children never use the appliance unattended In addition make sure that children do not remove small parts from the device as they could suffocate by swallowing parts Hint Fire and injure hazard due to ...

Page 2: ...s such as power amplifiers or mixing consoles DMX cables enable trouble free operation and the highest possible transmission reliability of signal data Do not use microphone cables Hint Condensation To avoid condensation in the unit the unit should adapt to the ambient temperature before commissioning Hint Unwanted odours A new product can sometimes lead to unwanted odours This reaction is normal ...

Page 3: ...e The installation of the device should always be carried out by experienced personnel and must be carried out in compliance with the mechanical and electrical safety regulations in your country Hint Fog fluid Disconnect the device from the mains before filling Do not fill with hot liquids Only use high quality water based fog fluids recommended by your dealer Other fog fluids can lead to clogging...

Page 4: ...7453 Tel 49 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product LightmaXX Vector Haze 1 7 is used exclusively for the generation of artificial fog by vaporizing the filled fog fluid The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and...

Page 5: ...n on the device itself Display and menu buttons The device has 4 operating keys and an LCD display on which all settings can be addressed and read Button Function Description Interval Set 5 200sec Duration Set 5 200sec Timer mode setting Timer Out 1 100 Menu Volume Out 1 100 Fan Speed 1 100 DMX Add 001 512 Fluid sensor on off Timer Up Up Activate Timer function Volume Down Down Activate Volume fun...

Page 6: ...the timer mode Setting the Fog Level for Volume Mode To adjust the fog quantity press Menu until the display shows Volume out Use the Up Down buttons to adjust the fog volume from 1 to 100 This setting is required if you want to use the option Volume Continuous Mode Setting the fan speed To set the fan speed press Menu until the display shows Fan Speed Use the Up Down buttons to set the fan speed ...

Page 7: ... the timer mode The display indicates the set time interval Interval xxx s The unit counts down to 0 seconds and emits fog To deactivate the timer mode press the Stop button Volume Continuous Mode Press the VOLUME button to activate continuous fog output The display indicates Volume followed by the value that was set in menu item Volume Out Duration xxx s To stop the fog output press the Stop butt...

Page 8: ...MX software or the DMX output of a device already in your DMX chain Always use a DMX cable with a 110 Ohm resistor for this connection Address the device according to your DMX configuration The following table shows the respective DMX modes of the individual devices with the corresponding values and functions Channel Value Function 1 000 005 Off 006 255 1 100 Fan Speed 2 000 005 Off 006 255 1 100 ...

Page 9: ...ENGLISH Connections and controls ...

Page 10: ...ation 1 Output nozzle 8 Fuse 2 Fan 9 Power input Power Twist 3 Air baffle adjustable 10 DMX Out 3 pol 4 Castors 11 DMX In 3 pol 5 Butterfly lock for removable cover 12 Display 6 Carrying handle 13 Menu buttons 7 Fluid tank compartment ...

Page 11: ...r consumption 1650 Watt Fog fluid tank capacity 5 Liter Fog fluid consumption 1 42ml min DMX connection 3 pol DMX channels 2 Power connection Power Twist Fuse 250 10A Dimensions L x W x H 660 x 300 x 610 mm Weight 34 Kg Symptom Troubleshooting No function Check the mains connection and the fuse No fog output Check the fill level of the fluid container No reaction in DMX mode Check the cable connec...

Page 12: ...set the output to Zero and wait for minimum 30 seconds before to switch off the unit This allows the unit to execute its cleaning process so all the remaining fluid is removed from the internal circuits Switch off the unit unplug the mains cable and wait 10 minutes until the unit has been cooled down During inspection the following points should be checked All screws used for installing the device...

Page 13: ... on the packaging Disposal of batteries Batteries do not belong in the garbage Please keep batteries in accordance with the official collection points or disposal stations in accordance with the specifications Disposal of your old device Do not dispose of the device with household waste This device is subject to the WEEE Directive Waste Electrical and Electronic Equipment in its currently valid ve...

Page 14: ...ENGLISH MS ID LIG0016334 000 09 2019 Notes ...