ENGLISH
Set interval
To set the interval, press "
Menu
" until "
Interval set
" appears on the display.
Then use the Up/Down buttons to set the fog pause from 5 to 200 seconds.
This setting is required if you want to use the
timer mode
.
Setting the fog duration
To set the duration, press "
Menu
" until the display shows "
Duration set
".
Use the Up/Down buttons to set the fog duration from 1 to 200 seconds.
This setting is required if you want to use the
timer mode
.
Setting the Fog Level for Timer Mode
To set the fog quantity for the timer mode, press "
Menu
" until the display shows "
Timer out
".
Use the Up/Down buttons to set the fog quantity from 1 to 100%.
This setting is required if you want to use the
timer mode
.
Setting the Fog Level for Volume Mode
To adjust the fog quantity, press "
Menu
" until the display shows "
Volume out
".
Use the Up/Down buttons to adjust the fog volume from 1 to 100%.
This setting is required if you want to use the option
Volume (Continuous Mode)
.
Setting the fan speed
To set the fan speed, press "
Menu
" until the display shows "
Fan Speed
".
Use the Up/Down buttons to set the fan speed between 1 and 100%.
Setting the DMX address
To set the DMX address, press "
Menu
" until the display shows "
DMX ADD xxx
".
Then use the Up/Down buttons to set the value from 001 to 512.
Activating/deactivating the liquid sensor
Press "
Menu
" until "
Fluid sensor
" appears in the display.
Use the Up/Down buttons to activate or deactivate the fluid sensor (On/off).
When the Fluid sensor is activated, the display shows "Ready to Fazer S".
If the Fluid sensor is deactivated, the display shows "Ready to Faze".