background image

WARRANTY

- The manufacturer shall repair or replace a luminaire that has been found to be defective under

normal  use  through  no  fault  of  the  customer  provided  that  it  was  delivered,  stocked,
mounted/installed and operated in conditions and according to the requirements specified in a
product  data  sheet,  engineering  specifications,  mounting  and  service  instructions,  delivery
terms, rules for technical maintenance of electrical installations and other conditions agreed by
the  manufacturer  and  the  customer  during  the  warranty  period  or  expanded  warranty  period
specified below.

- The  luminaire  is  a  serviceable  device.  When  installing  the  luminaire,  free  access  should  be

provided for service or repair. The manufacturer is not responsible and will not compensate any
expenses related to construction work, rental vehicles etc. in case the repair site is not readily
accessible.
The statutory warranty period is determined by the applicable law, and may vary from country to
country. The manufacturer undertakes statutory warranty obligations in the amount and within
the time frame stipulated by the applicable law.

- Warranty  period  -  60  months  from  date  of  delivery  subject  to  terms  and  conditions  specified

herein and on the manufacturer’s website at https://www.ltcompany.com/en/terms/

- Warranty does not apply to color change of painted surfaces and plastic parts during luminaire

operation.

- The warranty period of emergency power supply units (supplied with rechargeable battery) and

illumination  control  system  components  (supplied  without  luminaires)  is  limited  to  12  (twelve)
months from date of delivery.

- Warranty does not apply to color change of painted surfaces and plastic parts during luminaire

operation. 
Luminous flux level is at least 70% of the nominal value during the warranty period.

- Warranty  will  cover  the  entire  period,  given  that  assembly,  installation  and  operation  of

luminaires  are  handled  by  specialized  technical  personnel  and  according  to  the  luminaire's
manual. 

- The  service  life  of  the  luminaires  under  normal  climatic  conditions  subject  to  installation  and

usage instructions is:
·   8 years – for luminaires with body and/or optical parts (diffuser) made of polymeric materials.
·   10 years - all other luminaries.

- The  manufacturer  reserves  the  right  to  make  modifications  to  the  product  that  improve  its

end-user performance. 
The  manufacturer  is  not  liable  for  typographical  and  other  errors  that  may  have  occurred  in
printing. 

- Storage.

The luminaire should be stored in heated and ventilated warehouses, storages with conditioned
air  which  situated  at  any  climatic  region  and  with  temperature  from  +5  to  +40°С  and  relative
humidity not more than 80%.
NiCd, NiMh batteries: Temperature range +5 to +40°C
When storing for more than 6 months it is recommended to refresh batteries - 5 cycles of
charging-discharging
Transportation in manufacturer's package could be done by any mode of transport as long as
protection from mechanical damage and precipitation is provided.

ACCEPTANCE CERTIFICATE

The luminaire meets the requirements of applicable EC directives.
Manufacture date _____________________________________________________________
Inspected by ___________________________________________________________________
Packaged by________________________________________________________________
Manufacturer: company LLC "IGC "Lighting Technologies'
-
-

7

Summary of Contents for 1997027060

Page 1: ...HB LED FLOODLIGHT Manual Montageanleitung ...

Page 2: ...nal value Luminous flux flickeing 5 Luminaire corresponds to the protection classification IP by IEC 60529 Diffuser type Polycarbonate lenses Further information about luminaire s dimensions shown in the table please see Overall and installation dimensions section Notizen Die zulässige Abweichung der Werte Leistung Lichtstrom Masse von den Sollwerten beträgt 10 Die zulässige Abweichung der CCT Wer...

Page 3: ...Weight kg Length A mm Width B mm Heigth С mm Mounting dimension D mm Mounting dimension E mm Einschaltstro m А Einschaltstro mimpulszeit μs Gewicht kg Länge A mm Breite B mm Höhe c mm Montagemaß D mm Montagemaß E mm 65 250 37 880 535 360 320 100 3 ...

Page 4: ... operate the luminaire if the diffuser is undamaged Unauthorized disassembling modification and repair is prohibited In case of malfunction the luminaire should be immediately switched off and report to manufacturer or specialized luminaire service The luminaire has passed a high voltage test for insulation and electric strength according to IEC 60598 1 The LED luminaries are considered as low haz...

Page 5: ...Connect wires to free terminals L grey terminal N blue terminal PE yellow green terminal Replace cover back and tighten the screws Tightening torque 5 Nm Tighten cable gland nut until sealing is fully pressed against cable 4 For luminaries with HFD HFR Disassemble the connector Strip power cable external insulation 30 mm inner 8 mm max core section 2 5 mm2 Put cable through connector s nut and con...

Page 6: ...Overall and installation dimensions mm 1 HB LED 400 2 HB LED 600 3 HB LED 800 CONNECTION SCHEMES 1 Mains connection scheme 2 Mains connection scheme for luminaire with 1 10V regulated control gear 6 ...

Page 7: ...nths from date of delivery Warranty does not apply to color change of painted surfaces and plastic parts during luminaire operation Luminous flux level is at least 70 of the nominal value during the warranty period Warranty will cover the entire period given that assembly installation and operation of luminaires are handled by specialized technical personnel and according to the luminaire s manual...

Page 8: ...Company stamp More information can be found on our website https www ltcompany com en Hotline 0049 89 550 59 8611 8 ...

Page 9: ...n Sie die Leuchte nur in Betrieb wenn der Diffusor nicht beschädigt ist Nicht autorisiertes Zerlegen Modifizieren und Reparieren ist verboten Im Falle einer Fehlfunktion sollte die Leuchte sofort ausgeschaltet werden und sich beim Hersteller oder spezialisierten Leuchtenservice melden Leuchte hat einen Hochspannungstest für Isolation und Spannungsfestigkeit gemäß IEC 60598 1 2011 bestanden Die LED...

Page 10: ... Aderquerschnitt 2 5 mm2 und in die Kabelverschraubung 1 einführen Die Adern an die freien Buchsen der Klemmenblöcke anschließen L grauer Block N blauer Block PE gelbgrüner Block Deckel aufsetzen Schrauben festziehen Anzugsmoment 5 Nm Ziehen Sie die Überwurfmutter an bis die Dichtung zusammengedrückt ist 4 Für Leuchten der HFD HFR Stecker zerlegen Entfernen Sie die Isolierung des Stromkabels PC au...

Page 11: ...Gesamt und Einbaumaße der Leuchte 1 HB LED 400 2 HB LED 600 3 HB LED 800 ANSCHLUSS SCHEMA 1 ANSCHLUSS SCHEMA 2 Netzanschlussschema für Leuchten mit 1 10V geregelten Betriebsgeräten 11 ...

Page 12: ...eckt sich über den gesamten Zeitraum da Produktion Montage und Bedienung der Leuchten von spezialisiertem Fachpersonal und gemäß Bedienungsanleitung durchgeführt werden Die Lebensdauer der Leuchte unter normalen klimatischen Bedingungen beträgt mindestens 8 Jahre insofern die Installation und Betriebsanweisungen befolgt werden 8 Jahre für Leuchten mit Gehäuse und oder optischen Teilen Diffusor aus...

Page 13: ...Hotline Nummer 0049 89 550 59 8611 20 09 2020 2 01 14 13 ...