WARNING!!!
To avoid exposition to UV-C rays please provide a total shielding of the modules, or automatic turning OFF disposals at
the entry doors in the environment treated. There must be no direct irradiation of the personnel.
To shield the devices, you can use materials with opaque surfaces such as stainless steel or aluminum, but also
transparent materials such as glass or Lexan
®
; to have further information please contact us.
To improve safety, we suggest you to add light signs or signboards to report the potential danger.
Remember to switch on the device ONLY IF there is adequate shielding and no accidental
exposure to rays by the personnel.
SCHEDULING
Connect electric power to the device. The light lamp will turn on. Remember not to expose people to UV-C ray
irradiation by ensuring all personnel have dispersed.
ELECTRICAL CONNECTIONS
•
We suggest you to let a qualified electrician to install this device, following these instructions and the
electrical scheme, and following the CEI norms.
•
Make sure that the device will be installed where it will fit with the existing environmental conditions. Before
connecting the device to the electrical line, make sure that the labelled data on the device are the same as the
ones of the electrical line; we remind you that the electrical supply power of this device is 220-240V, 50/60Hz.
•
Make sure that the electrical system is suitable to provide the supply current required by the device (please
read the label).
•
The connection to the electrical line needs a multipolar switch.
•
The connection to the electrical line must be made by the supplied cable 3 x 1 mm
2
.
•
The use of screws, nuts, or other means, is necessary to connect the device to the electrical line.
•
We suggest the use of counters to know exactly the life of UV lamps and to remember when replace them.
•
Protect the power supply cable from high temperature, sharp corners, water, oils.