background image

LIGHT PROGRESS

 

DIRECT-H-NX [Eng.]

 

Rev. 3 Eng. Oct 2020 

Pag. 14/16

 

 

 
 

 
 

 

 

DECLARATION OF COMPLIANCE

 

 

We, LIGHT PROGRESS S.r.l., hereby declare under our own responsibility that the following units of own production: 

 

UV-DIRECT…-H-NX series

 

 

 

 

 

are in accordance with EEC directive 2014/30/EU (Electromagnetic Compatibility) 

 

are in accordance with EEC Machinery Directive dispositions 2006/42/EU 

 

are in accordance with EEC Low Voltage Directive 2014/35/EU 

 

are in accordance with EEC (RoHS) 2011/65/EU (D.Lgs 4 Marzo 2014, n.27) 

 

TECHNICAL STANDARDS APPLIED

 

 

UNI EN ISO 12100:2010

  Safety of Machinery - Basic Concepts, General Principles for Design - Risk 

assessment and risk reduction 

UNI EN ISO 13857:2008

  Safety of Machinery - Safety Distances to prevent danger zones being reached 

by the upper and lower limbs (2008) 

ISO 14120:2015

 

Safety of Machinery - Guards - General Requirements for the Design and 

construction of fixed and movable guards 

UNI EN ISO 13849-1:2016

 

Safety of Machinery - Parts of the Control System related to the Safety – Part 1: 

General Design Principles 

UNI EN ISO 14119:2013

  Safety of Machinery - Interlocking devices associated with guards - Principles for 

design and selection 

CEI EN 60204-1/2016

 

Safety of Machinery - Electrical Equipment of Machines. Part 1: General Rules 

(2010) 

EN 61439-1:2011

 

Low-voltage Switchgear and Control Gear Assemblies. Part 1: General rules 

 

FURTHER TECHNICAL STANDARDS APPLIED:

 

 

IEC EN 60335-1 "Safety of household electrical appliances and similar” 

Electronic Ballasts for the control of the lamps in accordance with the standard EN 60928. 

Germicidal UV-C Lamps in accordance with EN 61199. 

Electrical Protective Measures in accordance with IEC 70-1, EN 60229. 

 

 

Anghiari, 4.22.2020 

 

 

 

 
 

 
 
 

 

Responsible for Standards:  Dr. Aldo Santi 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

LIGHT PROGRESS S.r.l. Loc. San Lorenzo, 40 - 52031 ANGHIARI (AR) - ITALY - 

http://www.lightprogress.com

 

Summary of Contents for UV-DIRECT NX Series

Page 1: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 1 16 INSTRUCTION UV DIRECT NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H H NX UV DIRECT E75H H NX...

Page 2: ...ance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper re...

Page 3: ...ction manual must be preserved and must always be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not...

Page 4: ...ly prior to the entry of the operators to allow entry in a freshly disinfected site Operation can also be managed by means of appropriate power units that especially in case of installation of various...

Page 5: ...ackaging and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occu...

Page 6: ...its should be carried out so as to distribute them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on t...

Page 7: ...ss steel brackets supplied anchoring them to the ceiling by screw anchors 8 to 10 mm or by self tapping screws not supplied After inserting the anchors onto the ceiling you should tighten by supplied...

Page 8: ...spersed ELECTRICAL CONNECTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that th...

Page 9: ...PV Multi pole plug and socket Wire Meaning Black wire for LED terminal n 1 Wire n 1 1 anode LED for synoptic 2 cathode LED MASTER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase...

Page 10: ...s on the lamp housing and let them slide along the lamp grab the lamp at the 2 ends and pull it in a direction parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING U...

Page 11: ...T Code n 1 EB 55P n 1 EB 55P continuous operation Selective UV C lamp at 253 7 nm with high efficiency lighting Body in Stainless Steel AISI 304 All the used materials are tested for resistance to int...

Page 12: ...rogress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personnel F...

Page 13: ...ese instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits component parts lists instructions for...

Page 14: ...f Machinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1...

Page 15: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 15 16 Notes...

Page 16: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 16 16...

Page 17: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 17 16...

Reviews: