User Parameters
Space Speed: During work, the max operation speed of laser head when laser off.
The value range of this parameter is limited to Axis [Max Speed] of manufacturer
parameter, shall not be bigger than max speed of the manufacture parameter.
Start Speed: Start speed during processing, the value range of this parameter is
limited to Axis. Start Speed of manufacturer parameter, shall not be bigger than
max speed of the manufacture parameter.
Speed Factor: Factor determining the turn speed in work. The bigger the factor is,
the faster the work-speed is. Then bigger dither accordingly. Value range
between 0~5, normally set at 2.
Space Jerk: Speed of acceleration during space process. The bigger the value is,
the faster the space is; results in a bigger dither accordingly. Value range is
between 10000~60000 normally.
Cut Jerk: Speed of acceleration during cutting process. The bigger the value is, the
faster the cutting is; results in a bigger dither accordingly. Value range is between
5000~50000 normally.
Min Acc.: Min acceleration of axis movement during processing.
Cut Acc.: Max acceleration of laser head movement during processing when laser
on. Normally set below 1500.
Space Acc.: Max acceleration of laser head movement during processing when
laser off. Normally set below 2000.
Engrave Acc.: Max acceleration of laser head movement during processing when
engraving. Normally set above 8000. Too small a setting will lead to too long of a
distance before initial speed accelerates to engraving speed, causing a failed
engraving because of out-of-range.
16