background image

 
 
 

  M a n d a l a   V N   S t a r   U s e r   M a n u a l

 | 9

 

 

 

www.light-mandalas.com 

 

3

 

Installation and Operation Instruction 

3.1

 

Setup 

1.

 

Before starting to use the device, ensure the Laser Key Switch is turned OFF to 
prevent any damage to your eyes from laser light. 

 

 

2.

 

Plug in the power cord. Use only AC 100-240 V, 50-60 Hz. 

 

 

3.

 

Turn ON the Power Switch. 

    

 

 

Summary of Contents for Mandala VN Star

Page 1: ...User Manual Mandala VN Star Please read the manual before using the tools Version 2 ...

Page 2: ...2 Warning 2 1 3 Warranty 3 1 4 Precautions 3 1 5 Maintenance 4 1 6 Product Include 5 2 Technical Data 6 2 1 Specifications 6 2 2 Overview and Function 7 3 Installation and Operation Instruction 9 3 1 Setup 9 3 2 Crystal Holder 11 3 3 Photoporation Crystal Bead 13 3 4 Light Wand and L Shape Holder 14 3 5 Extra 50mm Spheres 17 4 Fault Diagnosis 18 ...

Page 3: ...formed into a four dimensional space Within these processes it helps people absorb photons faster and more efficient than before It s suitable for relaxation wellness studios health retreats and personal meditation spaces 1 2 Warning Pay close attention to each safety REMARK and WARNING statement in the manual This manual contains important laser system safety and operation information Read and un...

Page 4: ...manufacturer reserves the right to exchange components of the product instead of repairing it If the failure results from misuse or neglect the user must pay for all cost that may occur The freight cost and other costs will be depending on which Term Conditions criteria the product falls into Import tax and Customs clearance duty cost is not included in the term of warranty In that case you may as...

Page 5: ...leaning the tool or not in use 1 5 Maintenance 1 Clean with soft cloth humid tissue moistened with water or a water based glass cleaner 2 Clean the cooling fans with cotton swap when they are covered with dust 3 Protect the Laser Output Head with Light Wand Cable plug in 4 In order to guarantee the fixture works properly it s essential to keep it clean ...

Page 6: ...yramid Crystal Holder x1 c Support Piece x1 3 Crystal Holder x1 4 L Shape Holder x1 5 Laser Key Switch x2 6 Harmonistic Universe Sphere 50 mm Alpha Sphere x1 7 AC power cord x1 8 Extra 50mm Spheres Merkaba Theta Sphere x1 Merkaba in Flower of Life Gamma Sphere x1 Universal Harmony Sphere x1 9 Photoporation Crystal Bead Set x1 1 2a 3 4 7 5 2b 2c 6 9 8 ...

Page 7: ...Input Voltage AC 100 240 V 50 60Hz Power Max 50W Laser Power Violet Mandala VN Star Class 3B 200mW 405nm Scanning speed 0 30kpps Laser Pattern Unlimited Patterns Cooling System Fan Cooling Operation temperature Indoor 10 35 C Case Color Black Case Material Aluminum and Acrylic black Machine size 260 x 180 x 90 mm Gross Weight 3kg ...

Page 8: ...M a n d a l a V N S t a r U s e r M a n u a l 7 www light mandalas com 2 2 Overview and Function Front View and Top View Side View Cooling Fan ...

Page 9: ...pply Power Input socket build in fuse and spare fuse 3 Sensitivity Knob Pattern size adjustment from 5 to 100 clockwise 4 Laser Key Switch Switch ON and OFF the laser 5 Energy Information Transfer EIT Scalar Generator Switch Switch ON and OFF the EIT function 6 Display Screen Display Bluetooth connection status of the device and smartphone tablet 1 2 3 4 5 6 ...

Page 10: ... com 3 Installation and Operation Instruction 3 1 Setup 1 Before starting to use the device ensure the Laser Key Switch is turned OFF to prevent any damage to your eyes from laser light 2 Plug in the power cord Use only AC 100 240 V 50 60 Hz 3 Turn ON the Power Switch ...

Page 11: ...ck laser light Please be careful your eyes 6 Tune the Sensitivity Knob to adjust the size of laser pattern recommend tune to 1 or 2 0 clock Tune too low will cause burn on CPL filter or crystal which placed in front as the laser is to concentrate therefore the output power is too intense Tune too high will cause damage to the laser module ...

Page 12: ...default patterns Make sure the display screen is showing INTR AL as it means the device is ready to pair with APP When the device is Bluetooth connected paired with tablet app Mandala Star it will show APP STANBY MODE Bluetooth connected paired with tablet APP 3 2 Crystal Holder 1 Turn OFF the laser 2 Place crystal sphere into the Holder ...

Page 13: ... com 3 Clench both Crystal Holder and Harmonistic Sphere then install to the laser output head 4 Lock the Crystal Holder by turning the screw Please DON T over screw as it will cause the crystal holder to crack 5 Turn ON the Laser Key Switch to release the laser light ...

Page 14: ...s with the laser pattern healing frequency but also the remedy substance healing frequency as well 1 Use a dropper or syringe to put several drops of the remedy substance into the Photoporation Crystal Bead and seal with silicon caps tightly 2 Place remedy substance filled Photoporation Crystal Bead into the freezer 3 When the remedy substance is freeze place the frozen remedy filled Photoporation...

Page 15: ...andalas com 3 4 Light Wand and L Shape Holder Light Wand 1 Turn OFF the laser 2 Plug in the Light Wand Cable into the laser output head Please follow the diagrams below to ensure the cable is installed correctly Install the Support Piece to the laser output head ...

Page 16: ...stall the Pyramid Crystal Holder onto the cable Turn ON Laser Key Switch to release the laser Tune the Sensitivity Knob to adjust the brightness of light wand In order to receive complete pattern energy it s recommended to adjust sensitivity knob to 9 or 10 o clock Adjust too over will cause the projected pattern to be too big which unable the pattern to fit in completely into light wand ...

Page 17: ... r M a n u a l 16 www light mandalas com L Shape Holder 1 Install the L Shape Holder to the laser output head 2 User can put the large size mineral on the holder or install the Pyramid Crystal Holder with crystal bead inside onto it ...

Page 18: ...ithin different vibration range Strength Stunning Suggest to use for a short period only unless you are able to be in balance with those vibrations Gamma Sphere Good for both Physical and Energy healing meditation purposes Create a stable penetrating ability energy field Harmonious energy field allow us to heal and transform Strength Stable and High Universal Harmony Sphere A harmony and neutral d...

Page 19: ...on the specification Check On Off switch if it is fully turn ON Check the cable female socket Is it fully inserted into the device power socket Check power fuse condition i Unplug the power cord ii Use a key to take out the fuse iii Check fuse condition if there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced ...

Page 20: ...ndalas com No laser pattern output Check if the Laser Key Switch is turn ON Tune the Sensitivity Knob to adjust the pattern size Check the Bluetooth connection of the device and tablet The display screen of the device will show APP if it s connected to the tablet ...

Page 21: ...r there has never been any reported side effects using light color and sound therapy anywhere in the world and throughout time Notes on the practices of low level laser therapy LLLT and Biofeedback Low level laser therapy LLLT is considered investigational by the FDA and no medical claims of cures are permitted in the US at this time however low level lasers are defined within the scope of complim...

Page 22: ...t Mandalas Official Technical Support Email cservice light mandalas com Local agents contacts Japan japan light mandalas com Taiwan lovelight777888 gmail com Indonesia lightseed2020bali gmail com West Malaysia lightworker healingtech org East Malaysia malaysia light mandalas com Hungary horesnyibela light mandalas com Switzerland Germany Austria and the Netherlands info light mandalas ch France Sp...