Maintenance
DANGER!
Disconnect from the mains before starting any maintenance work.
Switch off the unit, unplug the mains cable and wait until the unit is cool down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly
fastened and may not be corroded.
Housing, fixations and installations spots (ceiling, truss, suspensions) should be
totally free from any deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be
replaced.
The mains cables must be in impeccable condition and should be replaced when
even a small problem is detected.
In order to protect the device from overheat the cooling fans and ventilation
opening should be cleaned monthly.
The interior of the device should be cleaned annually using compressed air.
The cleaning of in internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends on
the environment which the fixture operates: damp, smoke or particularly dirty
surroundings can cause greater accumulation of dirt on the unit
’
s optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least every 30 days.
Clean the internal optics at least every 90 days.
Important: we strongly recommend internal cleaning to be carried out by
qualified personnel!