9. Replacing The UV Lamps
To maintain the sterilizing efficacy, the UV tubes need to be replaced after 9,000 hours of
use. When the lamps need to be replaced, the icon of
“Lamp Replacement Indicator” turn
from white to red and stay flashing.
If the lamps are not replaced in time, the product will stop operating and automatically lock
to protect the disinfection effect in the room. Replace the lamps as soon as possible.
• Before carrying out any replacement, wait about 15 minutes after switching off the product
(to let the UV tubes cool down to avoid scalding).
Steps:
1. Push in on the right side of the front
door and release to open.
* The other two doors can be opened by
pushing out from inside.
2. Loosen the 2 screws and remove
the UV shield cover by pulling it out.
* If the screws are too tight to turn by hand,
use a screwdriver to loosen them first.