Removing Batteries
1)
Rotate latch at the front of the pod counter-clockwise 1/8 turn or until it
stops.
2)
Pull the front cap off the pod.
3)
Pull the battery from the pod using removal strap (Refer Fig. 3 & 4).
Mounting Battery Pods
Battery Pods can be mounted prior to installing batteries
into pods.
1)
Remove the rear plate or monitor back of the housing.
2)
Slide the battery pods into housing channels (Refer fig. 3 & 4).
3)
Insert Pod Locker between the pods and tighten using 1/8” allen wrench
(Refer fig. 5). Do not over tighten.
Installing and Using QuickConnects
Depending on which housing you purchased and if you purchased SunRay Pro-
S Lights separately, you may need to install QuickConnects to the housing,
light, or light arm or all three. If your housing and light system already has
QuickConnects attached or has universal mounts, skip ahead to the
appropriate section for light system assembly
6
(Fig. 3 - BlueFin and Mako alignment)
(Fig. 4 - StingRay alignment)
(Fig. 5)
(Fig. 6)
5
Charging Batteries
Due to shipping, batteries charge states will vary. It is
recommended that you charge your Mini TC batteries
when they are received.
1)
The charger can accept an electrical range of 100 - 240v and 50 - 60hz.
2)
The charger has two LED lights, one green and one yellow.
Green LED illuminates when charger is receiving power.
Yellow LED is illuminated when charging and blinking when charge is
complete.
3)
To attach charger to battery, align arrow on charger connector with arrow on
battery label and push together until connectors seat. (Refer fig. 1)
Charge time for the 10.8v fast charger is approximately 1.5
hours.
Installing Batteries
1)
Slide the battery back into the pod with the contact end inserted first so that
the connector will align with the socket inside the pod. (Refer fig. 2)
2)
Servicing the o-rings (See o-ring maintenance).
3)
Replace the front cap onto the pod.
Insure that the removal strap attached to the battery does
not interfere with the seal when the end cap is attached to
the pod
4)
Turn the knob on the end cap clockwise 1/8 turn until it stops. The endcap
will now be locked into place. The endcaps are specific to the left and right
pods.
(Fig. 1)