EQUIPMENT SPECIFICATIONS
Template Assisted Crystallization is registered trademark
of Next Filtration Technologies, Inc.
The ScaleSolver™ SSC-4025 is complete, self-contained, loaded with media and ready to use. A simple inlet and
outlet connection is all that is required for installation. Please review operating pressures, temperatures and water
chemistry limitations to ensure compatibility.
PowerTAC™ Physical Properties
• Composition - Specially treated polymer
• Size - 0.450 - 650mm in sealed replaceable cartridge
Operating Conditions
Can be used in continuous or intermittent operation. Install on cold water
supply only. No backwash required.
Water Chemistry Specifications
• pH
6.5 to 8.5
• Max. Hardness
75 grains (1300 ppm CaCO3)
• Temperature
41 to 140˚ F (5-60˚ C)
• Max. Chlorine
<3 ppm
• Max. Iron, ferrous
0.3 mg/I
• Max. Manganese
0.05 mg/I
• Max. Copper 1.3 mg/I
• Oil & H2S
Remove pre PowerTAC™
• Polyphosphates
Remove pre PowerTAC™
Specifications
• Max. Dimensions
24.5” x 7.25”
• psi @ Flow Rate
1 psi
@
15 gpm (0.1 bar
@
57 Lpm)
• Max. Temperature
100˚ F (37.8˚ C)
• Max. Pressure
90 psi
Using ScaleSolver™ with other water treatment equipment.
Due to the unique properties of ScaleSolver™
, there are some unique requirements
for using ScaleSolver™
in conjunction with filtration or other forms of water
treatment.
1. ScaleSolver™ must be the last stage in the treatment chain.
Do not install any
filters after ScaleSolver™ or before any devices for which scale prevention is
required. POU filters, e.g. carbon or RO are exempt from this requirement.
2. Do not apply phosphate or any other antiscalant either before or after
ScaleSolver™.
7-1/4”
Installation, Operation and Maintenance Manual
ScaleSolver SS-4025
TM