background image

Figure 4: 810  Commercial System  

52”

8”

®

49.5”

8”

IN (1”)

RINSE 

LINE 

OUT (1”)

IN (1”) OUT (1”)

Place this system vertically on a smooth, level surface.

 This system operates in an UP-Flow, fluidized bed mode. Level surface is 

required. 

The system may be placed in any position during shipping and installation but must be operated in the vertical 

position.

 

The system should be placed within 5 feet of a 110-volt electrical outlet. 

A 24-volt transformer can be used if no outlet is available 

within five feet. Be sure to secure the transformer to the electrical outlet with the screw provided.

The ScaleSolver must be the final stage in the treatment chain. 

DO NOT install the water filter post ScaleSolver.

Do not let the system freeze. 

Damage to the tank may result.

System Location Requirements

Installation Instructions 

All installations are required to be completed in accordance with all local building 
and plumbing codes. 

  

         NOTE: If a re-circulating pump is present

 on your hot water heater, unplug the pump 

        PRIOR to shutting off the water supply to avoid a burnout of the pump motor.

 

1. Place the tanks where they are to be installed. Pay close attention to the 
    direction of the arrows on each valve head. 

2. First begin with the ScaleSolver by opening up the inlet valve first and then the 
    outlet valve. 

        

 NOTE:

 The ScaleSolver unit operates in the UPFLOW mode which is opposite of 

         a conventional softener. Both the inlet and outlets are clearly marked on tank.  

3. As the ScaleSolver fills with water, allow cold water to run through a faucet or    
    hose bib to release air from tank. 

4. Water flowing from faucets may be white, allow water to run until clear. 
     This takes approximately 10-15 minutes.

5. Shut off faucets and place ScaleSolver on bypass before setting up the filtration 
    unit.

        

NOTE: 

If installing a sediment filter, plumb in the sediment filter pre the water 

        filter. Arrows indicate in and out.  Care should be taken to cool the plastic 
        casing when soldering nearby pipe connections.  The building ground wire, if 
        necessary, should be looped around the system to maintain proper grounding.

6. Filtration unit valve heads are shipped separately. To properly set up the filter,     
     fill tank with water, remove the blue tape on the center riser pipe and screw on  
     the valve head securely.

7. Before turning on the main water line, set the built-in bypass lever to the   
    BYPASS position. 

[FIG 2]

810 Commercial System Installation 

and Setup Water Filter 

Installation 

Instructions 

Summary of Contents for 810 Series

Page 1: ...c 787179 NV Lic 059578 LifeSource Water Systems Inc 523 S Fair Oaks Ave Pasadena CA 91105 LifeSourceWater com Customer Service 626 792 9996 Model 810 Commercial Water System Installation and Operations Guide ...

Page 2: ... In Service Weight 90 lbs Chlorine must not be above 3 0 PPM The 810 Commercial Water Filter is a no maintenance whole facility water filtration system This system includes a fully automatic valve head that runs a self rinsing cycle every 14 days Inlet Connection 1 Outlet Connection 1 Max Dimensions 52 x 8 Max Flow Rate 10 gpm Max Temperature 140 F In areas where outside temperatures are less than...

Page 3: ...efrigerator water line beneath the sink and on any other water lines in the building Any such filters if retained should be routinely changed per manufacturers recommendations A suitable outlet to drain the rinse water must be made available for filter That outlet can either be a ground location that has a sufficient percolation a driveway or a drain DO NOT CONNECT THE FILTER RINSE LINE TO AN AIR ...

Page 4: ... close attention to the direction of the arrows on each valve head 2 First begin with the ScaleSolver by opening up the inlet valve first and then the outlet valve NOTE The ScaleSolver unit operates in the UPFLOW mode which is opposite of a conventional softener Both the inlet and outlets are clearly marked on tank 3 As the ScaleSolver fills with water allow cold water to run through a faucet or h...

Page 5: ...illed about 4 apart along the pipe lying on the ground to better distribute the water in a garden area DO NOT cap the end of the pipe or connect the end of the pipe to a drip line NOTE If using the 24 volt transformer run wire and make connections but do not plug in 9 Turn on the main water supply and check all connections for leaks NOTE After installing the filtration tank it is extremely importa...

Page 6: ...ver to the SERVICE position The water will continue the self cleaning cycle Leave the bypass lever in the SERVICE position MANUAL RINSE CYCLE INSTRUCTIONS 4 Rotate the control knob at the top of the tank SLOWLY clockwise to RAPID RINSE between 4 and 5 o clock Stop and leave it on RAPID RINSE for 2 to 3 minutes Water will be running out the rinse line during this time See Figure 5 5 Then turn the c...

Page 7: ...grammed to self rinse once every 14 days for 30 minutes between 2 a m and 3 a m Water pulled into the building at this time will not be filtered by the system If you would like self rinsing to occur at a time other than 2 a m you must adjust the TIME OF DAY For example if you would like self cleaning to occur between 12 a m and 3 a m which is two hours earlier than programmed you must set the TIME...

Page 8: ...water to run until it is fairly cool Consult your manufacturer instruction manual for draining tankless water heaters Immediately After Installation Traditional Water Heaters Boilers Tankless Water Heater Water Doesn t Taste Right Check Bypass See if the bypass on BOTH TANKS are in the service position See Figure 10 11 Check Electrical Make sure power plug on the WATER FILTER is plugged into elect...

Page 9: ...o use single use dishwasher detergents Pods Packs or Tabs These will overwhelm your dishwasher with excess soap Excess soap will cause excess water spots and glazing We recommend Cascade Complete One teaspoon of Cascade Complete detergent and 1 teaspoon of Sour Salt Citric Acid or Glass Magic as a rinsing agent will produce excellent results Lime or Soap Scum Buildup If you currently have lime bui...

Page 10: ...rees F 3 That failure has not resulted from misuse alteration freezing accident fire or neglect The automatic timer valve used by LifeSource Water Systems has a three year warranty on parts if installed as required by the manufacturer There will be no service charge for the first 90 days if installed by the factory WATER PRESSURE EXCEEDING 100 PSI CAN DESTROY THE INNER WORKINGS OF THE TANK AND VAL...

Page 11: ...tion for Gas and Water The ScaleSolver system including the tank media and valve head is warranted for performance for a period of three years from the date of the original installation The ScaleSolver warranty is four years when installed in conjunction with a LifeSource Water System in the proper configuration LifeSource Water Systems Inc warrants the ScaleSolver system as follows Our obligation...

Reviews: