Figure 4: 810 Commercial System
52”
8”
®
49.5”
8”
IN (1”)
RINSE
LINE
OUT (1”)
IN (1”) OUT (1”)
Place this system vertically on a smooth, level surface.
This system operates in an UP-Flow, fluidized bed mode. Level surface is
required.
The system may be placed in any position during shipping and installation but must be operated in the vertical
position.
The system should be placed within 5 feet of a 110-volt electrical outlet.
A 24-volt transformer can be used if no outlet is available
within five feet. Be sure to secure the transformer to the electrical outlet with the screw provided.
The ScaleSolver must be the final stage in the treatment chain.
DO NOT install the water filter post ScaleSolver.
Do not let the system freeze.
Damage to the tank may result.
System Location Requirements
Installation Instructions
All installations are required to be completed in accordance with all local building
and plumbing codes.
NOTE: If a re-circulating pump is present
on your hot water heater, unplug the pump
PRIOR to shutting off the water supply to avoid a burnout of the pump motor.
1. Place the tanks where they are to be installed. Pay close attention to the
direction of the arrows on each valve head.
2. First begin with the ScaleSolver by opening up the inlet valve first and then the
outlet valve.
NOTE:
The ScaleSolver unit operates in the UPFLOW mode which is opposite of
a conventional softener. Both the inlet and outlets are clearly marked on tank.
3. As the ScaleSolver fills with water, allow cold water to run through a faucet or
hose bib to release air from tank.
4. Water flowing from faucets may be white, allow water to run until clear.
This takes approximately 10-15 minutes.
5. Shut off faucets and place ScaleSolver on bypass before setting up the filtration
unit.
NOTE:
If installing a sediment filter, plumb in the sediment filter pre the water
filter. Arrows indicate in and out. Care should be taken to cool the plastic
casing when soldering nearby pipe connections. The building ground wire, if
necessary, should be looped around the system to maintain proper grounding.
6. Filtration unit valve heads are shipped separately. To properly set up the filter,
fill tank with water, remove the blue tape on the center riser pipe and screw on
the valve head securely.
7. Before turning on the main water line, set the built-in bypass lever to the
BYPASS position.
[FIG 2]
810 Commercial System Installation
and Setup Water Filter
Installation
Instructions