LifeSOS LS-30 Operation Manual Download Page 4

 

 

Thank you for purchasing the LS-30 IP Based Wireless Security & Automation Control System. 

By adopting modern microprocessor control and communication technologies, the LS-30 is designed to 

provide all the most advanced features that you need to protect your home and business. Moreover, you 

can operate the system and read its status by using the proprietary GUI (Graphic User Interface) 

HyperSecureLink

 through the Internet, from all over the world. The LS-30 is not only a security system 

but also an automation controller that allows you to set as many as 15 programmable switches to execute 

daily commands throughout a whole week. With optional environmental sensors and auto-control switches, 

the LS-30 also operates as an environmental monitor/control center to record all the environmental data 

and save your energy consumption automatically. 

Although the LS-30 is a very powerful device, thanks to the 

interactive HMI

 (Human Machine Interface) 

programming technology, its operation is simple. Just follow the instructions shown on the LCD display 

by answering the questions with YES/NO buttons or pressing the correct keys, and the settings are done. 

You can also set up the system on your laptop or PC using the optional USB/RS-232 adapter and 

HyperSecureLink 

software.  

The set up is simple, switch on back up battery, connect the Base Unit to power, enroll sensors and 

accessories, connect the telephone line, set the telephone numbers and record the voice messages, and then 

the LS-30 is at your service.   

As your security requirements grow and you become more familiar with the system, you can expand and 

accessorize the LS-30 to meet your specific needs. Simply call your local dealer; trained professionals can 

answer any questions you have regarding additional accessories. 

Main Features:   

 

Smart Home System with Security, Environment monitoring/ control and energy saving. 

 

Computer and Internet interface to set, download and upload system parameters and events. 

 

Interactive programming with 16 x 2 LCD display. 

 

Detailed 512-event log with time tag. 

 

288 sensors/ zones can be accommodated with15 programmable switches. 

 

Receiving RF signal strength indication and jamming detection. 

 

Robust multi-million RF coding and special transmission timing design, avoiding interferences. 

 

Responds to panic, burglary, fire, medical alarm and environmental hazards. 

 

Burglar zones with supervised sensors, door and window open/ close detection. 

 

Special Monitoring mode to record all the activities in the protected area without triggering the alarm. 

 

9 independent partial arm zones, one LS-30 can operate as 10 independent burglar alarm systems. 

 

Automatic operation and switch control by schedule and scene settings. (Only can be set by computer.) 

 

Built-in voice dialer stores up to 10 phone numbers, 1 pager, 5 GSM numbers and 2 CMS data links. 

 

Hands-free speakerphone, two-way voice communication. 

 

Dial-in control of listen-in, 2-way communication, arm, disarm, event report and switch control. 

 

Latchkey function to inform parents when kids leave or return home. 

 

AC power loss and restore will inform the user by voice. 

 

Inactivity monitoring to take care of the elderly or physically challenged at home. 

 

Remote access through Internet by Ethernet Adaptor or through PSTN by Data Communication Module. 

 

Alarm report through Internet with fast response and saving communication charges. 

 

Back up GSM Module in case the telephone link fails. 

    (Ethernet Adaptor, Data Communication Module and GSM Module are optional devices.) 

2

Summary of Contents for LS-30

Page 1: ...L Li if fe eS SO OS S THE ADVANCED SECURITY AUTOMATION SYSTEM FOR YOUR HOME BUSINESS Model LS 30 OPERATION MANUAL V5 20...

Page 2: ...4 Set Device 28 4 4 1 Change Device Setting 29 4 5 Set Siren 31 4 6 Set Misc 32 4 7 Set GSM 33 5 CMS Mode 34 SPECIFICATIONS 35 APPENDIX 36 A 1 In coming Message Display A 2 Connection Diagram for USB...

Page 3: ...INTRODUCTION INSTALLATION 1...

Page 4: ...specific needs Simply call your local dealer trained professionals can answer any questions you have regarding additional accessories Main Features Smart Home System with Security Environment monitori...

Page 5: ...for Relay Module XRM 01 X 10 Power Line Interface Controller and GSM Module 5 AUX Audio Refer to the APPENDIX A 6 Audio I O for GSM module GSM Module is optional Key Board Status Display Emergency But...

Page 6: ...are divided into five main categories 1 32 Controller Panic Devices C Remote Controller Keypad Card Reader 2 128 Burglary Sensors Sirens B Door Magnet PIR Passive Infrared Glass Break Detector Vibrati...

Page 7: ...4 7 Set GSM b Record voice message Refer to 4 3 Set Sound Record Voice c Enroll all the wireless devices by registering their ID codes in the Base Unit Refer to 4 4 Set Device Enroll Device 6 Set oth...

Page 8: ...SSI Receiving Signal Strength Indication reading on the LCD by pressing the test button on the sensors Relocate the sensors Base Unit to get the best reading dB number if necessary If the dB number is...

Page 9: ...USER OPERATION 7...

Page 10: ...Sub state of State A 2 Right arrow State A 3 Enter into the sub state Note Pressing FUNC ESC at any time will let you leave the current state loop Password As many as 14 passwords can be set in the s...

Page 11: ...nto the specific operation mode directly Clear LED LCD alarm warning status reset siren and stop dialing immediately Ignore the password request Enter HOME Mode Quick Home Press the key for 2 seconds...

Page 12: ...The Burglar sensor B numbered 01 02 issued a burglar alarm at 01 13 19 32 this event is numbered as 253 Ex 3 LCD shows Z00 11 Disarm 12 22 08 00 03 The Master user number 1 enters the Base Unit Z into...

Page 13: ...rent telephone numbers Reading the Telephone Number Display If the telephone number is over 16 digits it will be divided into two parts to be shown on the screen use the key to check the lower part of...

Page 14: ...heck By Sequence Medical Button Check By Zone Number Special Sensor Check the current status of all the devices using the and keys to scroll up and down the number Reading the Device Status Display Ex...

Page 15: ...oorbell sound Ding Dong when receiving a triggering signal from a Burglar sensor with its Bell ON OFF status set in the ON state Bell OFF No doorbell chime will sound Note The Bell function only works...

Page 16: ...The Base Unit can t communicate with the RS 232 USB Adaptor Data Communication Module and Ethernet Adaptor Set Switch Default X 10 type X 10 Type House Code A P default A This code should be the same...

Page 17: ...ose burglar sensors with their Enable State Home Mode Active will still be on alert and offer the protection you need while at home Refer to 4 4 1 Installer Mode Set Device Change Device Setting Burgl...

Page 18: ...rs Besides CMS Voice message on telephone Voice on Base Unit Siren Status Burglar PIR Door Magnet Glass Break Detector Vibration Sensor GSMSMS1 5 Pager Burglar Common 1 4 GSM Voice1 5 Burglar Common S...

Page 19: ...ts immediately stop any further dialing stop siren Press 1 LS 30 disconnects immediately and dials the next number stop siren Press 3 Enter into speak only mode The microphone on the LS 30 is disabled...

Page 20: ...fter the password has been recognized the LS 30 will enter into monitoring mode for 30 seconds and then after two beeps the system will enter into 2 way hands free speaker phone automatically Ten 10 s...

Page 21: ...INSTALLER CMS SETTINGS 19...

Page 22: ...4 Installer Mode Set Timer 4 1 Set Telephone 4 2 Set Sound 4 3 Set Device 4 4 Set Siren 4 5 Set Misc 4 6 Set GSM 4 7 4 1 Set Timer Set Entry Delay Set Exit Delay Set Inner Siren Time Set Relay Action...

Page 23: ...econds to leave the house set Exit Delay 30s Disarm Exit Delay AWAY ARM effective System status 0 255 seconds Set AWAY mode This Delay only works on the Controller with its Delay ON OFF setting in ON...

Page 24: ...e proper Tone or Pulse mode for the auto dialer Auto Answer Ring Count Auto Answer ON with Ring Count 1 30 Auto Answer OFF default Auto Answer OFF Auto Answer ON The Base Unit will answer the incoming...

Page 25: ...Mode 30 Minutes CMS Report OK default 30 Minutes 30 Minutes The auto dialer stops dialing after 30 minutes or after all the telephone numbers have been dialed 5 times without a successful connection C...

Page 26: ...will be dialed only when the LS 30 is triggered by the specified alarm For example the fire number will be dialed only in a fire alarm Latchkey number Power status report number This number will be di...

Page 27: ...uence for Alarm Report CMS1 PSTN GSM Number CMS2 PSTN GSM Number GSM1 SMS GSM5 SMS Pager Specific alarm number 1st to 4th Common numbers GSM1 Voice GSM5 Voice If there is any number that cannot be con...

Page 28: ...your name address and telephone number Ex This is I live at phone number is Panic Segment 4 seconds The voice to be played during a Panic alarm Ex Break in Break in Calling for emergency help Burglar...

Page 29: ...end of the delay time Refer to 4 1 Set Timer Entry Delay Entry Delay Beep OFF No beeps during the Entry Delay interval Alarm Warning ON OFF default OFF Alarm Warning ON The Base Unit generates Dong s...

Page 30: ...nsors ID code in the initial system setup Each sensor has a unique ID that is preset at the factory 60 seconds for Device Enroll After initiating the Enroll Device procedure there is a 60 second time...

Page 31: ...de Active Inactive PIR default Inactive Magnet default Active For Burglar sensor Home Mode Active This Burglar sensor will trigger an alarm in Home Mode operation Home Mode Inactive This Burglar senso...

Page 32: ...sensor Supervision OFF System will not check the heartbeat signal from this sensor Type Alarm Control default Type Alarm For Special Sensors To assign the Special Sensor as an Alarm Device or a Contr...

Page 33: ...rens will keep silent when the operation mode changes Tamper Siren In Disarm ON OFF default OFF Tamper Switch There is a Tamper Switch in the Base Unit please refer to Attach the Base Unit to the wall...

Page 34: ...as been detected in 12 hours 2 If no activity has been detected during this time from any Inactivity Sensor Refer to 4 4 1 Change Device Setting Burglar Sensor Enable State Inactivity the system will...

Page 35: ...refer to 4 2 1 is blank or the connection failed GSM ID This can be the mobile phone number of the SIM card of the GSM module when you buy the service from your GSM system provider you will receive a...

Page 36: ...h a digital receiver using Contact ID and has 2 way voice capability DTMF Data Time 50ms 100ms for PSTN report default 50ms For PSTN Select the DTMF data pulse time as 50ms or 100ms for the Contact ID...

Page 37: ...Back up Time Min 3 months after power break Battery Back Up Operation Time about 15 26 hours standby depends on back up battery type only for the operation of the Base Unit Password 14 passwords each...

Page 38: ...te and are not allowed in the message A 2 Connection Diagram for USB or RS 232 Computer Interface COM1 cable USB or RS 232 Adaptor HyperSecureLink Software To PC USB or COM Port To LS 30 COM1 Note For...

Page 39: ...utput represents the status of system operation mode In the ARM mode AWAY HOME this output will send out 5V voltage protected by a serial 2k ohms resistor to this terminal The user can connect a LED d...

Page 40: ...tection function should be disabled Refer to 4 2 Set Telephone Set Telephone Line Cut Detection Permanent Off otherwise the LS 30 will trigger the line cut detection alarm when the TAM or Fax has take...

Page 41: ...Device List Item Device Name Zone No xx xx Location User Name Initial Date of Battery 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Reviews: