Safety Precautions
Safety Precautions
IMPORTANT SAFETY INSTRUCTIONS
•Safety Precautions
·To ensure safe and correct use of the massage chair, do not operate it without reading this
operation manual carefully.
•Do not use the massage chair when the upholstery or seat is removed. This may cause injury
or malfunction.
· Do not use the massage chair in combination with other therapeutic equipment or electric
blanket, etc., as this may result in ineffectiveness or injury.
· Do not use the massage chair an hour before or after eating as this may have adverse effects
on the user.
· Do not allow children or pets to play around the massage chair, e.g., behind the backrest, under
the seat or leg rest of the massage chair. This may result in injury.
· Do not rest or place heavy objects on the armrests, leg rest or backrest as this may result in
malfunction or injury.
• Do not use the massage chair when your body is wet.
· Do not operate the massage chair with wet hands.
· It is not recommended to use the massage for more than 15 minutes.
· Do not perform continuous massage on the same spot of your body for more than 5 minutes at
a time as this may result in excessive stimulation and may have adverse effects.
•Do not insert your hand or foot along the paths of the massage rollers during use as this may
cause injury.
·Stop operation immediately if you experience any discomfort.
·This product is not intended for self-treatment of conditions that should be managedby a
qualified health care provider.
· People on medication or with medical conditions, please consult your doctor before use.
Please do not use the product if you are not feeling well.
• Remove all scarves, neckties, necklaces and jewel ry before using the massager.
People with Medical Conditions
Consult your doctor before use if you:
• are under medical rest as ordered by a doctor.
have spinal disorders, an abnormal spinal condition or have suffered a spinal injury.
have back problems.
have diabetes, osteoporosis or sensory impairment.
have joint dysfunction.
have a pacemaker or other electronic medical devices.
may be pregnant.
have phlebitis or thrombosis.
have an increased risk for blood clots.
had recent surgery.
have surgical pins, screws, or anything mechanical implanted in your body.
SAVE THESE INSTRUCTIONS
Safety Instruction
•WARN ING
The power plug must be fully inserted into and appropriate outlet.Improper connection of
the equipment-grounding conductor could result in an e lectric shock.
Check with a qualified electrician and servicemen if you are in doubt as to whether the
product is properly grounded. Do not modify the power plug provided by the product. If
the outlet is not suitable. please ensure that a proper outlet is installed by qualified
E lectric ian.
When using the massage chair, basic precaution should always be followed to reduce
the risk of electric shock, an injury or burns to the person.
Read the followi ng details before usage:
1. Do not use the massage chair outdoors and avoid places with direct sunlight.
2. Do not use the massage chair in places where the humidity is high .
3. Do not use the massage chair near any heating device or fire .
4. Do not use the masso
• chair when smoking
5.Recommended to unplug the power supply after use.
6.Please ensure that a proper outlet is installed by qualified electrician, Improper
connection of the equipment-grounding conductor could result in an electric shock.
Caut ion
·The massage chair is to be used indoors only.
•If you use the massage chair in a cold room, do not increase the room temperature
abruptly. It is recommended that you increase the temperature gradually to a normal level.
· If the massage chair is stored in a cold place and is being brought into a warm environment
,
it is advisable to wait one hour before use. This is because its performance may not be at
optimum level, as there may be water droplets on the mechanical parts due to
condensation.Using the massage chair under such conditions may result in malfunction.
User-Mai ntenance In s t r u c t io n
User-maintenance instructions shall include:
a) Instructions for c leaning and user maintenance operations re commended by the
manufacturer, such as lubrication or nonlubrication , and a statement to the user that any
other servicing should be performed by an authorized service representative or that the
appliance has no user serviceable parts.
b)lnstructions for an appliance employing an automatically reset thermal limiter that
shuts off the entire appliance shall inform the user what to expect if the thermal limiter
operates
c)Specific instructions for the proper method of storage of the cord, the total appliance,
and the like, when the appliance is not in use, and for care of the cord while in use(for
example, for a hand-supported product, untwisting)
d)In the case of an appliance intended to be used with water additives
,
conditioners, or
other solutions with or without water, specific instructions regarding the proper liquid or
additive to use and the amount to be used in conjunction with the appliance